Ductless Fume Hood,Floor-standing,2060H*800W*620D

Reference Price:US$from $650

Min. Order:1 unit

Short Description:

The floor-standing Ductless Fume Hood, with dimensions of 2060mm in height, 800mm in width, and 620mm in depth, provides an effective and space-efficient solution for safely handling hazardous fumes in laboratory settings without the need for external ducting.

  • Type: Ductless Fume Hood
  • External dimensions: 2060*800*620
  • Specifications: -
  • Cabinet Type: Floor-standing
  • Door Options: 2-door
  • Cabinet Material: Steel baked enamel
  • Glass Window: 5mm thick tempered glass
  • Countertop Options: Physicochemical board

Cleanroom Passbox

Ductless Fume Hood,Floor-standing,2060H*800W*620D

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

Ductless Fume Hood,Floor-standing,2060H*800W*620D

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Features

Ductless fume hoods are designed with several important features to ensure safety and functionality in laboratory environments. Key features include:

Multi-Stage Filtration.jpg

01
Multi-Stage Filtration

Equipped with activated carbon and HEPA filters to effectively capture fumes, vapors, and particulates.

Real-Time Airflow Monitoring.jpg

02
Real-Time Airflow Monitoring

Integrated sensors or indicators that provide alerts for optimal airflow and filter status.

Adjustable Sash.jpg

03
Adjustable Sash

Allows users to modify the opening height for comfort and safety, enhancing accessibility while maintaining protection.

Compact and Portable Design.jpg

04
Compact and Portable Design

Space-efficient construction that can be easily relocated, making them ideal for small laboratories.

Principle

A ductless fume hood operates by drawing contaminated air from the laboratory into the hood, where it is passed through filters designed to capture harmful substances. 

Unlike traditional fume hoods, which exhaust air outside, ductless fume hoods recirculate the filtered air back into the lab. 

The filters used in ductless fume hoods can include HEPA filters, activated carbon filters, or other specialized filtration media, depending on the type of chemicals or particles being handled. 

This system provides a safe environment by preventing exposure to hazardous fumes while eliminating the need for external venting systems.

How ductless fume hoods work

Models

Product ModelSize(H*W*D)mmconfigurebilliards tableLower cabinet door type
DNJQTFG8002060*800*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 8 filters, 1 fanEpoxy CountertopDouble Door/Manual
DNJQTFG10002060*1000*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 8 filters, 1 fanEpoxy CountertopsDouble Door/Manual
DNJQTFG12752060*1275*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 12 filters, 3 fansEpoxy CountertopsFour-door/manual
DNJQTFG16002060*1600*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 12 filters, 3 fansEpoxy CountertopsFour-door/manual
Product ModelSize(H*W*D)mmconfigurebilliards tableLower cabinet door type
DNJQTFG8002060*800*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 8 filters, 1 fanEpoxy CountertopDouble Door/Manual
DNJQTFG10002060*1000*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 8 filters, 1 fanEpoxy CountertopsDouble Door/Manual
DNJQTFG12752060*1275*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 12 filters, 3 fansEpoxy CountertopsFour-door/manual
DNJQTFG16002060*1600*620Seven-inch LCD touch screen, VOC concentration environmental monitoring and integrated alarm system, 12 filters, 3 fansEpoxy CountertopsFour-door/manual

Accessories

2270266SFA-EWService Fixture Set for Water
2270408SFA-EHWService Fixture Set for Hot Water
2270416SFA-EDIService Fixture Set for DI Water
2270406SFA-EHService Fixture Set for Hydrogen
2270265SFA-EGService Fixture Set for Gas
2270306SFA-EVService Fixture Set for Vacuum
2270313SFA-ENService Fixture Set for Nitrogen
2270440SFA-EOService Fixture Set for Oxygen
2270275SFA-ECService Fixture Set for Compressed Air
2270433SFA-ECO2Service Fixture Set for CO2
2270274SFA-EAService Fixture Set for Argon
1110105EQR/FC-FAN-PP025PP025 Exhaust Fan
1110087EQR/FC-FAN-PP030PP030 Exhaust Fan
2270266SFA-EWService Fixture Set for Water
2270408SFA-EHWService Fixture Set for Hot Water
2270416SFA-EDIService Fixture Set for DI Water
2270406SFA-EHService Fixture Set for Hydrogen
2270265SFA-EGService Fixture Set for Gas
2270306SFA-EVService Fixture Set for Vacuum
2270313SFA-ENService Fixture Set for Nitrogen
2270440SFA-EOService Fixture Set for Oxygen
2270275SFA-ECService Fixture Set for Compressed Air
2270433SFA-ECO2Service Fixture Set for CO2
2270274SFA-EAService Fixture Set for Argon
1110105EQR/FC-FAN-PP025PP025 Exhaust Fan
1110087EQR/FC-FAN-PP030PP030 Exhaust Fan

FAQ

1. What is a ductless fume hood?

A ductless fume hood is a type of laboratory equipment designed to provide a safe work environment by filtering harmful fumes and vapors without the need for external ductwork. These hoods utilize a built-in filtration system to clean the air before recirculating it back into the laboratory. They are particularly useful in settings where traditional ducted hoods are impractical or where space is limited.


2. How does a ductless fume hood work?

A ductless fume hood operates by drawing in air from the user’s workspace, which contains potentially hazardous fumes or vapors. This air is then passed through a series of filters designed to capture contaminants. The filtered air is recirculated back into the laboratory, ensuring a cleaner and safer environment for users. The main components include a fan, filters, and an airflow control system, which work together to maintain optimal performance.


3. What are the benefits of a ductless fume hood?

Ductless fume hoods offer several advantages, including:

  • Portability: They can be easily moved or relocated.

  • No need for external ducting: This simplifies installation and reduces costs.

  • Space-saving: They are ideal for laboratories with limited space.

Additionally, ductless fume hoods can help improve air quality in the lab by continuously filtering out harmful substances, thus enhancing the overall safety and comfort of laboratory personnel.


4. How do I choose the right ductless fume hood?

Choosing the right ductless fume hood involves considering several factors, including the specific applications you plan to use it for, the types of chemicals you will handle, and the size of the hood. It is crucial to select a model with appropriate filtration capabilities for the substances you’ll be working with, as well as ensuring that the hood fits comfortably in your workspace. Consulting with a laboratory safety expert can also help guide your decision.


5. What materials can be used in a ductless fume hood?

A ductless fume hood can accommodate various materials, including solvents, acids, and other chemical reagents, provided they fall within the hood’s filter specifications. Common materials used in constructing ductless fume hoods include:

  • Polypropylene: Resistant to many chemicals.

  • Steel: Offers durability and strength.

  • Glass: Provides visibility and easy cleaning.

Always refer to the manufacturer’s guidelines to ensure compatibility with specific materials.


6. Are ductless fume hoods safe?

Yes, ductless fume hoods are generally considered safe for use when properly maintained and used according to the manufacturer’s guidelines. They are equipped with filters that effectively capture harmful vapors and protect laboratory personnel from exposure. However, it is essential to regularly monitor filter performance and replace them as needed to ensure ongoing safety. Users should also adhere to safety protocols and wear personal protective equipment when working with hazardous materials.


7. What is the difference between ducted and ductless fume hoods?

The primary difference between ducted and ductless fume hoods lies in their ventilation systems. Ducted fume hoods exhaust air outside the building via ductwork, effectively removing harmful contaminants from the laboratory. In contrast, ductless fume hoods recirculate filtered air back into the workspace, making them suitable for environments where external venting is not feasible. Each type has its advantages and is suited for different applications, depending on the laboratory’s needs.


8. How often should a ductless fume hood be maintained?

Maintenance of a ductless fume hood is crucial for ensuring safety and effectiveness. It is recommended to conduct a thorough inspection at least once a month, which includes checking the filters, airflow, and overall condition of the unit. Filters should typically be replaced every six months, but this can vary based on usage and the types of chemicals handled. Regular maintenance helps prevent contamination and ensures optimal performance.


9. What filters are used in a ductless fume hood?

Ductless fume hoods use various filters depending on their intended applications. Common types include:

  • Activated carbon filters: Effective for organic vapors and odors.

  • HEPA filters: Designed to capture particulates and aerosols.

  • Acid gas filters: Used for specific corrosive gases.

It’s important to select the right filter type based on the chemicals being used to ensure maximum protection.


10. Can a ductless fume hood be used for all chemicals?

A ductless fume hood cannot be used for all chemicals. Its effectiveness depends on the type of filters installed and their compatibility with specific chemicals. While many organic solvents and low-toxicity chemicals can be safely handled, substances that produce highly corrosive fumes or require specialized filtration systems may not be suitable for ductless hoods. Always consult the manufacturer's specifications and safety data sheets (SDS) for the chemicals you intend to use.


11. How do I install a ductless fume hood?

Installing a ductless fume hood is relatively straightforward compared to ducted systems, as it does not require extensive ductwork. Begin by selecting a suitable location that provides adequate clearance and accessibility. Ensure that the hood is placed on a stable surface and secured according to the manufacturer’s guidelines. Connect the electrical supply as needed, and check that the filters are properly installed. Finally, perform an airflow test to ensure the system is functioning correctly before use.


12. What is the cost of a ductless fume hood?

The cost of a ductless fume hood can vary widely based on several factors, including size, type, and manufacturer. On average, you can expect to pay anywhere from \$2,000 to \$10,000. Additional costs may arise from necessary accessories, such as replacement filters and installation services. When budgeting, it’s important to consider both the initial investment and ongoing maintenance costs to ensure long-term safety and performance.

Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.