All-Steel Lacquered Air Shower - 1.4m(W) x 2.0m(D) x 2.2m(H) - 2 person
Reference Price:US$1950.00-3050.00




Select your requirements for air shower materials
Quantity:
Choose your Plate Thickness Requirements
Quantity:
Select your local supply voltage
Quantity:
Summary
All-Steel Lacquered Air Shower - 1.4m(W) x 2.0m(D) x 2.2m(H) - 2 person
Find Similar Products
-
All-Steel Lacquered Air Shower - 1.2m(W) x 1.0m(D) x 2.2m(H) - 1 person
US$500.00-1200.00
Min. Order:1 unit -
All-Steel Lacquered Air Shower - 1.4m(W) x 1.5m(D) x 2.2m(H) - 1-2 person
US$500.00-1200.00
Min. Order:1 unit -
All-Steel Lacquered Air Shower - 1.4m(W) x 1.0m(D) x 2.2m(H) - 1 person
US$500.00-1200.00
Min. Order:1 unit -
All-Steel Lacquered Air Shower - 1.2m(W) x 3.0m(D) x 2.2m(H) - 3-4 person
US$500.00-1200.00
Min. Order:1 unit -
All-Steel Lacquered Air Shower - 1.2m(W) x 2.0m(D) x 2.2m(H) - 2 person
US$500.00-1200.00
Min. Order:1 unit -
All-Steel Lacquered Air Shower - 1.2m(W) x 1.5m(D) x 2.2m(H) - 1-2 person
US$500.00-1200.00
Min. Order:1 unit
Air Shower Detail
The Painted Stainless Steel Air Shower is a state-of-the-art air shower system engineered to enhance cleanliness and minimize contamination in controlled environments. Made from high-quality stainless steel with a durable painted finish, this air shower combines superior corrosion resistance with an aesthetically pleasing design. Its smooth surface not only ensures easy maintenance but also meets the stringent hygiene demands of various industries.
Features
All-Steel Construction: Durable and corrosion-resistant.
Lacquered Finish: Smooth surface for easy cleaning.
High-Efficiency Air Filtration: Effectively removes dust and particles.
Rapid Airflow: Provides strong air jets for contamination control.
Energy-Efficient Design: Reduces energy consumption.
Smart Control System: Easy operation and
Various Size Options: Suits different space requirements.
High Safety Standards: Complies with industry regulations.
Price: a cost-effective air shower product
Air Shower Parameter
Indicator Model | 1`Purifier STD | 2`Purifier STD | 3`Purifier STD | 4`Purifier STD | 5`Purifier STD |
---|---|---|---|---|---|
Material Selection | 1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot) | ||||
Number of applicants | 1 person | 2 persons (affordable) | 3.4 persons (2 persons standard) | 3.4 persons (3 persons standard) | 6.8 persons (4 persons standard) |
Number of nozzles | 12 (bilateral) | 18 (bilateral) | 24 (bilateral) | 36 (bilateral) | 48 (bilateral) |
Air velocity | 24-30m/s | 24-30m/s | 24-30m/s | 24-30m/s | 24-30m/s |
Electronic lock brand | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks |
Efficient size | 600x600x120mm | 820x600x120mm | 600x600x120mm | 600x600x120mm | 600x600x120mm |
Overall Dimension | 1400W*1000D*2100H | 1400W*1500D*2100H | 1400W*2000D*2100H | 1400W*3000D*2100H | 1400W*4000D*2100H |
Internal dimensions | 800w*900D*1960H | 800w*1400D*1960H | 800w*1900D*1960H | 800w*2900D*1960H | 800w*3900D*1960H |
power supply | 380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground). The air shower room can be customized with 220V and 110V power supply according to customers' requirements.) | ||||
Lighting | LED recessed light 1pc | LED recessed light 2pc | LED recessed light 2pc | LED recessed light 3pc | LED recessed light 4pc |
Number of fans | 2 sets "0.55Kw/set | 2 sets~0.75KW/set | 4 units "0.55Kw/unit | 6 sets "0.55KW/set | 8 units*0.55Kw/unit |
Power of the whole machine | 1.1Kw | 1.5Kw | 2.2Kw | 3.3Kw | 4.4Kw |
Stall capacity (kg) | 350kg | 500kg | 650kg | 950kg | 1250kg |
Indicator Model | 1`Purifier STD | 2`Purifier STD | 3`Purifier STD |
---|---|---|---|
Material Selection | 1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot) | ||
Number of applicants | 1 person | 2 persons (affordable) | 3.4 persons (2 persons standard) |
Number of nozzles | 12 (bilateral) | 18 (bilateral) | 24 (bilateral) |
Air velocity | 24-30m/s | 24-30m/s | 24-30m/s |
Electronic lock brand | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks |
Efficient size | 600x600x120mm | 820x600x120mm | 600x600x120mm |
Overall Dimension | 1400W*1000D*2100H | 1400W*1500D*2100H | 1400W*2000D*2100H |
Internal dimensions | 800w*900D*1960H | 800w*1400D*1960H | 800w*1900D*1960H |
power supply | 380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground). The air shower room can be customized with 220V and 110V power supply according to customers' requirements.) | ||
Lighting | LED recessed light 1pc | LED recessed light 2pc | LED recessed light 2pc |
Number of fans | 2 sets "0.55Kw/set | 2 sets~0.75KW/set | 4 units "0.55Kw/unit |
Power of the whole machine | 1.1Kw | 1.5Kw | 2.2Kw |
Stall capacity (kg) | 350kg | 500kg | 650kg |
Indicator Model | 3`Purifier STD | 4`Purifier STD | 5`Purifier STD |
---|---|---|---|
Material Selection | 1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot) | ||
Number of applicants | 3.4 persons (2 persons standard) | 3.4 persons (3 persons standard) | 6.8 persons (4 persons standard) |
Number of nozzles | 24 (bilateral) | 36 (bilateral) | 48 (bilateral) |
Air velocity | 24-30m/s | 24-30m/s | 24-30m/s |
Electronic lock brand | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks |
Efficient size | 600x600x120mm | 600x600x120mm | 600x600x120mm |
Overall Dimension | 1400W*2000D*2100H | 1400W*3000D*2100H | 1400W*4000D*2100H |
Internal dimensions | 800w*1900D*1960H | 800w*2900D*1960H | 800w*3900D*1960H |
power supply | 380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground). The air shower room can be customized with 220V and 110V power supply according to customers' requirements.) | ||
Lighting | LED recessed light 2pc | LED recessed light 3pc | LED recessed light 4pc |
Number of fans | 4 units "0.55Kw/unit | 6 sets "0.55KW/set | 8 units*0.55Kw/unit |
Power of the whole machine | 2.2Kw | 3.3Kw | 4.4Kw |
Stall capacity (kg) | 650kg | 950kg | 1250kg |
Air Shower Structure
Explore the structural details of the Purifier Nxgan lacquered exterior and stainless steel interior air showers
As a key purification device, the Purifier Nxgan painted exterior and stainless steel interior air shower room incorporates multiple elements in its structural design to ensure effective air purification and operational stability.
Purifier Nxgan outside baking paint inside stainless steel air shower room technical parameters:
Outside size: 1220 × 2000 × 2050 (W × D × H)
Purification area size: 790 × 1920 × 1950 (width × depth × height)
Filter purification efficiency: ≥0.5um dust ≥99.99% (sodium flame method)
Nozzle wind speed: ≥27m/s or more to achieve the effect of dust removal
Air shower time: 0~99sec adjustable
Circulating air volume: 1600~2000M3/h
Electricity: 380V-50Hz or 220V-50Hz
Maximum power: 0.75KW
Weight: 460Kg
Size of high efficiency filter with partition: 610×610×120
Primary filter size: 600×300×21
Air Shower Usage
Air Shower Room Operation Steps
Prepare:
Ensure you are properly attired in cleanroom garments.
Verify that the air shower is operational.
Enter:
Step into the air shower room and close the door behind you.
Stand in the designated area and remain still.
Activate:
Wait for the air shower cycle to start automatically.
The air jets will begin, removing contaminants.
Exit:
After the cycle completes, open the exit door.
FAQ
1. What are the potential downsides of using an air shower?
High energy consumption (3-8 kWh per hour) and noise levels (65-80 dB) are common drawbacks. Frequent filter replacements and calibration requirements add long-term maintenance costs.
2. How to verify the efficiency of an air shower?
Use particle counters to measure airborne contaminants before and after operation. Validate airflow velocity (≥20 m/s) with anemometers and perform regular filter integrity tests via DOP/PAO scanning.
3. How do I select the right air shower model?
Consider user capacity (single/multi-person), industry-specific standards (ISO/GMP), and material compatibility. Prioritize models with programmable cycle times, ESD-safe features, and IoT-enabled monitoring for critical environments.
4. What types of filters are used in air showers?
HEPA filters (99.97% efficiency at 0.3µm) are standard. ULPA filters (99.9995% at 0.12µm) are used in semiconductor or pharmaceutical settings. Pre-filters capture larger particles to extend HEPA lifespan.
5. How does the filtration system in an air shower work?
Air is drawn through pre-filters to trap large particles, then pressurized through HEPA/ULPA filters. Clean air is ejected via nozzles in turbulent patterns to dislodge contaminants from surfaces, which are subsequently captured by the filters.
6. What are the benefits of an all-steel air shower?
Stainless steel resists corrosion, chemicals, and humidity, ensuring durability in harsh environments. Its non-porous surface allows easy decontamination, meeting strict hygiene standards in pharma and food industries.
7. What is the maintenance schedule for air showers?
Inspect pre-filters monthly and replace every 3-6 months. Test HEPA filters biannually and replace every 12-24 months. Lubricate door hinges quarterly and calibrate sensors annually to maintain performance.
8. What is the function of the control panel on an air shower?
The panel regulates cycle duration, monitors airflow velocity, and displays filter status. Advanced models include touchscreens for data logging, user access control, and integration with facility BAS systems.
9. What accessories are available for lacquered air showers?
Optional features include stainless-steel flooring, UV-C decontamination modules, RFID access systems, and emergency stop buttons. Soundproofing panels and humidity sensors enhance functionality in specialized setups.
10. Are lacquered air showers energy-efficient?
Modern lacquered models use variable-speed fans and automated standby modes, reducing energy use by 20-30% compared to traditional units. Insulated panels minimize thermal loss in temperature-controlled environments.
11. How do air showers fit into a larger cleanroom system?
They act as transitional buffers between cleanroom zones, maintaining pressure differentials. Integrated with gowning rooms and pass-throughs, they ensure sequential contamination control in ISO-certified workflows.
12. How to adjust the settings on an air shower?
Use the control panel to modify cycle duration (10-60 seconds), airflow speed, or activation modes. Password-protected menus allow admins to configure alarms, maintenance reminders, or user access levels.
13. How do air showers prevent contamination?
High-velocity turbulent airflow removes particles from clothing and equipment. Interlocked doors prevent simultaneous opening, while HEPA-filtered air creates positive pressure to block external contaminants.
14. How do air showers reduce static electricity?
Ionizing bars integrated into nozzles neutralize static charges on surfaces. Grounded flooring and ESD-safe materials further dissipate static, critical in electronics manufacturing and labs handling sensitive equipment.
15. How to integrate an air shower into an existing system?
Ensure electrical compatibility (380-480V/3-phase) and align doorways with cleanroom traffic flow. Modify HVAC ducting to maintain pressure gradients and install data ports for centralized monitoring.
16. How does an air shower improve air quality?
By removing 90-99% of surface particles (≥0.3µm) from personnel and objects, it reduces airborne contaminants. Continuous HEPA filtration maintains ISO-classified air purity levels in controlled environments.
17. What are the energy consumption metrics for air showers?
Standard units consume 3-5 kWh during operation. Larger models with dual blowers may use 6-8 kWh. Energy-efficient versions with EC motors reduce usage to 2-3 kWh while maintaining ≥20 m/s airflow.
18. What certifications should an all-steel air shower have?
Mandatory certifications include ISO 14644 (cleanroom standards), GMP (pharmaceutical compliance), and UL/CE electrical safety. Optional NSF or IEST certifications validate performance in specialized industries.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unit -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unit -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unit -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 unit -
Air Filter
US$3-50 USD/Unit
Min. Order:1 unit -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 unit -
Pass Box
US$200-500 USD/Unit
Min. Order:1 unit -
FFU
US$135-350 USD/Unit
Min. Order:1 unit -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 unit -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 unit -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 unit -
Clean room ceiling
US$
Min. Order:1 unit