Modular cleanroom project for aseptic preparation in Australian pharmacies.

Project address
Industry
Building area
ISO Class
Temperature
Humidity
Client logo

Client Profile

Layout diagram

Modular cleanroom project for aseptic preparation in Australian pharmacies. Layout diagram

1. GMP requirement
The cleanroom does not need to fully meet the requirements of a TGA-licensed GMP manufacturing facility (PIC/S PE 009).

It is intended for sterile compounding within a pharmacy setting. The design and performance should therefore align with ISO 14644 classifications and the principles used for sterile compounding in Australia (consistent with Pharmacy Board of Australia guidelines, which reference PIC/S PE 010 or equivalent standards such as USP <797>).

In practical terms, we need:

Full manufacturing GMP licensing and the associated documentation package are not required for this project.

2. AHU vs FFU solution
Given the relatively small footprint (~5 m × 5 m classified suite), a well-designed FFU-based system is acceptable and often preferred for this type of modular compounding cleanroom.

Please quote a FFU solution as the base option. If you also wish to offer a dedicated AHU alternative, we are happy to review both, but FFU is our preferred starting point for this size of suite.

Please ensure the FFU design can still achieve the required air changes, pressure differentials, and temperature control for the ISO 7 and ISO 8 zones under operational conditions.

Please proceed with the quotation on this basis. Let us know if you need any further details.


Legend

Australia Pharmacy · Peptide Injection Aseptic Compounding
External walls / partitions (hideable)
FFU filter fan units (downflow)
Cleanroom doors / interlock doors
Pass window 600×600×600 mm
Pressure cascade arrows (high→low)
Modular expansion port (indicative)
Drag to orbit · scroll to zoom · right-drag to pan
Monitoring points are annotated on the plan only, not shown in 3D

FFU Calculation (downflow supply / low-level return, no central AHU)

RoomGradeNet sizeVolume m³ACH designReq. airflowFFUACH actualCoverage m²Velocity m/s
Total units
Total supply
Single FFU: 1200×600 mm, nominal 1000 m³/h; ISO5 = full ceiling array, 2 cols × 8 rows = 16 units, as per approved layout.

FFU layout coordinates (ceiling, m)

IDRoomCentre (X,Y)

Room cascade / pressure cascade

ISO5 Core Room > ISO7 Buffer Room > ISO8 Ante-Room > Outside
Differential pressure between adjacent rooms ≥10-15 Pa; airflow from cleaner to less clean areas.
ISO 14644 / PIC/S PE 010 / USP 797 · supports local AU IQ/OQ only (not full TGA GMP licensing)