wap_menu MENU
X
Trusted by
companies like
FLIR Logo 1
electrolux Logo 3
abb Logo 4
bmw Logo 5
i-dent Logo 6
SINOPEC Logo 7
CATL Logo 8
INOVANCE Logo 9
EVE Logo 10
HONDA Logo 11
FOXCONN Logo 12
ISO 8 Hardwall Cleanroom - Overall View
ISO 7 Hardwall Cleanroom - External View
ISO 7 Hardwall Cleanroom - Inspector
ISO 7 Hardwall Cleanroom - Interior View
ISO 8 Hardwall Cleanroom - Overall View
ISO 7 Hardwall Cleanroom - External View
ISO 7 Hardwall Cleanroom - Inspector
ISO 7 Hardwall Cleanroom - Interior View

ISO 8 Softwall Cleanroom

Product Description:

Explore ISO 8 Hardwall Cleanrooms with modular panels, HEPA filtration, controlled airflow and customizable layouts. Get professional installation, on-site testing and documented handover support.

  • Cleanliness Class: ISO 8 (Class 100,000)

  • ≥0.5 μm Particles: ≤ 3,520,000/m³

  • Air Change Rate: 5–20 times/h

  • Average Airspeed: 0.05–0.2 m/s (mixed/turbulent flow)

  • Indoor Positive Pressure: 5–15 Pa (relative to adjacent areas)

  • Temperature: 18–26°C (typically ±2°C)

  • Relative Humidity: 30–65% (typically ±10%)

  • Filter Grade: HEPA H13 or H14 (depending on application)

  • Airflow Pattern: Mixed/Turbulent flow (via ceiling-mounted terminal filters)

  • Noise Level: ≤ 65 dB(A)

How to Work With Us

Requirements Consultation

Submit Requirements

Provide your site dimensions, required ISO class, and industry-specific needs (GMP, ESD, etc.) to our experts.

Technical Proposal

Custom Technical Proposal

Receive a detailed design proposal within 24 hours, including airflow strategies, material lists, and transparent pricing.

Precision Manufacturing

Modular Production

We manufacture your modular panels, HVAC units, and FFUs with strict QC to ensure full compliance with ISO 14644 standards.

Installation & Validation

Global Shipping & Setup

Fast global logistics followed by onsite installation guidance and performance validation to get you operational quickly.

Specifications & Models

Size (W*H*D)ft Size (W*H*D)Panel MaterialISO ClassArea (㎡)Area (sq.ft)Unit PriceStock Status
2m*3m*3m6′7″*9′10″*9′10″MGOISO86㎡64ft²106in²$3,600.00In Stock
4m*3m*3m13′1″*9′10″*9′10″MGOISO812㎡128ft²94in²$7,077.00In Stock
6m*3m*3m19′8″*9′10″*9′10″MGOISO818㎡193ft²56in²$10,430.00In Stock
8m*3m*3m26′3″*9′10″*9′10″MGOISO824㎡258ft²18in²$13,659.00In Stock
4m*5m*3m13′1″*16′5″*9′10″MGOISO820㎡214ft²113in²$11,520.00In Stock
6m*5m*3m19′8″*16′5″*9′10″MGOISO830㎡322ft²124in²$16,766.00In Stock
8m*5m*3m26′3″*16′5″*9′10″MGOISO840㎡430ft²135in²$21,669.00In Stock
10m*5m*3m32′10″*16′5″*9′10″MGOISO850㎡538ft²146in²$26,229.00In Stock
5m*8m*3m16′5″*26′3″*9′10″MGOISO840㎡430ft²135in²$21,669.00In Stock
8m*8m*3m26′3″*26′3″*9′10″MGOISO864㎡689ft²9in²$32,037.00In Stock
10m*8m*3m32′10″*26′3″*9′10″MGOISO880㎡861ft²126in²$37,714.00In Stock
2m*3m*3m6′7″*9′10″*9′10″MGO rockwoolISO86㎡64ft²106in²$3,857.00In Stock
4m*3m*3m13′1″*9′10″*9′10″MGO rockwoolISO812㎡128ft²94in²$7,591.00In Stock
6m*3m*3m19′8″*9′10″*9′10″MGO rockwoolISO818㎡193ft²56in²$11,201.00In Stock
8m*3m*3m26′3″*9′10″*9′10″MGO rockwoolISO824㎡258ft²18in²$14,688.00In Stock
4m*5m*3m13′1″*16′5″*9′10″MGO rockwoolISO820㎡214ft²113in²$12,377.00In Stock
6m*5m*3m19′8″*16′5″*9′10″MGO rockwoolISO830㎡322ft²124in²$18,051.00In Stock
8m*5m*3m26′3″*16′5″*9′10″MGO rockwoolISO840㎡430ft²135in²$23,383.00In Stock
10m*5m*3m32′10″*16′5″*9′10″MGO rockwoolISO850㎡538ft²146in²$28,371.00In Stock
5m*8m*3m16′5″*26′3″*9′10″MGO rockwoolISO840㎡430ft²135in²$23,383.00In Stock
8m*8m*3m26′3″*26′3″*9′10″MGO rockwoolISO864㎡689ft²9in²$34,779.00In Stock
10m*8m*3m32′10″*26′3″*9′10″MGO rockwoolISO880㎡861ft²126in²$41,143.00In Stock
Model: DI8SC‑233MGO
Size: 2m*3m*3m
ft Size: 6′7″*9′10″*9′10″
Panel: MGO
ISO: ISO8
Area(m²): 6㎡
Area(sq.ft): 64ft²106in²
Price: $3,600.00
Stock: In Stock
Model: DI8SC‑433MGO
Size: 4m*3m*3m
ft Size: 13′1″*9′10″*9′10″
Panel: MGO
ISO: ISO8
Area(m²): 12㎡
Area(sq.ft): 128ft²94in²
Price: $7,077.00
Stock: In Stock
Model: DI8SC‑633MGO
Size: 6m*3m*3m
ft Size: 19′8″*9′10″*9′10″
Panel: MGO
ISO: ISO8
Area(m²): 18㎡
Area(sq.ft): 193ft²56in²
Price: $10,430.00
Stock: In Stock
Model: DI8SC‑833MGO
Size: 8m*3m*3m
ft Size: 26′3″*9′10″*9′10″
Panel: MGO
ISO: ISO8
Area(m²): 24㎡
Area(sq.ft): 258ft²18in²
Price: $13,659.00
Stock: In Stock
Model: DI8SC‑453MGO
Size: 4m*5m*3m
ft Size: 13′1″*16′5″*9′10″
Panel: MGO
ISO: ISO8
Area(m²): 20㎡
Area(sq.ft): 214ft²113in²
Price: $11,520.00
Stock: In Stock
Model: DI8SC‑653MGO
Size: 6m*5m*3m
ft Size: 19′8″*16′5″*9′10″
Panel: MGO
ISO: ISO8
Area(m²): 30㎡
Area(sq.ft): 322ft²124in²
Price: $16,766.00
Stock: In Stock
Model: DI8SC‑853MGO
Size: 8m*5m*3m
ft Size: 26′3″*16′5″*9′10″
Panel: MGO
ISO: ISO8
<div

Key Features

ISO 8 rigid hardwall cleanroom construction
Rigid Hardwall Construction

The rigid hardwall enclosure provides a stable physical boundary for ISO 8 controlled environments. Modular wall and ceiling panels can be arranged according to room dimensions, equipment placement, personnel movement and material transfer requirements, supporting a durable cleanroom structure for manufacturing, assembly, inspection and laboratory applications.

HEPA air filtration system for ISO 8 cleanroom
HEPA Air Filtration System

The ISO 8 air filtration system can be configured with terminal HEPA filters, FFU units or a centralized AHU supply system according to the required airflow and room layout. Filter grade, airflow volume and replacement access are selected during engineering design to support particle control, routine maintenance and the applicable project performance requirements.

Flush-mounted panels for ISO 8 hardwall cleanroom
Flush-Mounted Cleanroom Panels

Smooth, flush-mounted wall and ceiling panels help reduce unnecessary ledges, exposed joints and difficult-to-clean interfaces. Panel cores, surface finishes and joint details can be specified according to cleaning agents, chemical exposure, fire-safety requirements, impact resistance and the intended operating environment.

Cleanroom doors and windows for ISO 8 cleanroom
Cleanroom Doors and Windows

Cleanroom doors, observation windows and pass-through boxes can be integrated into the hardwall enclosure to support controlled personnel and material movement. Door type, sealing details, vision panel size and interlocking functions can be selected according to traffic volume, room pressure relationships and operational procedures.

Positive pressure and airflow control in ISO 8 cleanroom
Positive Pressure and Airflow Control

The ventilation system can be designed to establish the required airflow pattern and pressure relationship for an ISO 8 cleanroom. Fan speed control, pressure monitoring and alarm functions may be included to help maintain stable operating conditions, limit ingress from adjacent areas and support timely response to abnormal conditions.

Environmental monitoring and control system for ISO 8 cleanroom
Environmental Monitoring and Control

Monitoring options may include room pressure, temperature, relative humidity, fan status and filter condition. Visual indicators, data recording and configurable alarms can be incorporated according to the project requirements, helping operators review environmental conditions and identify deviations during routine cleanroom operation.

Integrated lighting and utilities for ISO 8 cleanroom
Integrated Lighting and Utilities

Cleanroom LED lighting, electrical services and selected process utilities can be coordinated with the wall and ceiling system. Sealed fixtures, organized service routes and properly finished penetrations help simplify cleaning and inspection while allowing the installation to be adapted to equipment and production requirements.

ISO 8 cleanroom testing and documentation support
Testing and Documentation Support

Project documentation may include approved layout drawings, equipment schedules, filter information, operation and maintenance manuals, commissioning records and test reports. Following installation, applicable tests such as airborne particle counting, HEPA filter integrity testing, airflow measurement, pressure verification, temperature and humidity testing can be arranged according to the project specification and applicable cleanroom standards.

Custom Solutions

Our ISO 8 Hardwall Cleanroom solutions are configured around the process, room layout and contamination-control requirements of each project. The final design, equipment selection and acceptance criteria are confirmed according to the application and applicable standards.

Room Layout & Workflow

The cleanroom layout can be planned around production equipment, operating areas, maintenance access and future expansion. Personnel and material routes are arranged to reduce unnecessary movement and limit cross-contamination risks.

Personnel & Material Flow

Separate or clearly controlled personnel and material paths can be incorporated with gowning rooms, airlocks, pass boxes and designated transfer areas. The flow design should match the process sequence and site operating procedures.

HVAC & FFU Configuration

The HVAC or FFU system can be selected according to room volume, heat load, equipment arrangement and required air cleanliness. HEPA filtration, air distribution, pressure relationships, temperature and humidity targets are defined during engineering design and verified during commissioning.

Cleanroom Flooring

Flooring options may include seamless PVC, epoxy or other cleanable systems suitable for the application. The selected floor should provide a smooth, durable and easy-to-maintain surface, with load capacity and chemical resistance assessed according to the process.

Pass Boxes & Air Showers

Static or dynamic pass boxes can support controlled material transfer between areas. Air showers may be included where personnel or material decontamination is required. Door interlocks, dimensions, materials and installation positions are customized to the workflow.

Monitoring & Testing

Monitoring provisions can include differential pressure, temperature, relative humidity, particle concentration and equipment status. Handover testing may include particle counting, HEPA filter leak testing, airflow checks and pressure measurements, with results documented according to the approved project requirements.

Industry Applications

ISO 8 Hardwall Cleanrooms can be configured for pharmaceutical support areas, medical device assembly, electronics and precision component handling, optical inspection, laboratories and other controlled production or research environments.

Installation & Testing

Our ISO 8 Hardwall Cleanroom installation and testing process is organized to support reliable operation and documented performance verification according to the approved project requirements.

1. Site Preparation & Installation

We review the site conditions, approved drawings, room layout, utility connections and equipment positions before installing hardwall panels, ceilings, doors, viewing windows, flooring and cleanroom accessories.

2. System Commissioning

HVAC, FFU or AHU systems, HEPA filters, lighting, pressure monitoring devices and control systems are commissioned and adjusted to support the specified airflow, pressure and environmental conditions.

3. Airborne Particle Testing

Particle concentration is measured at defined locations under the agreed operating conditions to evaluate whether the cleanroom meets the specified ISO 8 cleanliness classification.

4. HEPA Leak Testing & Airflow Measurement

HEPA filter integrity testing is performed where required, together with airflow or air-volume measurements. The results help verify filter installation, air distribution and system performance.

5. Pressure & Temperature Testing

Room-to-room pressure differentials, temperature and relative humidity are checked against the approved design targets. Any required adjustments are completed before final acceptance.

6. Acceptance Documents & Handover

Handover documents may include as-built drawings, equipment manuals, calibration certificates, particle test reports, HEPA leak test records, airflow measurements, pressure readings and temperature and humidity records.

Final ISO 8 performance should be confirmed through documented on-site testing under the agreed operating conditions. Actual results may vary according to room size, equipment load, personnel activity, operating procedures and maintenance status.

FAQ

Are Deiiang ISO 8 Hardwall Cleanrooms compliant with regulations and standards?

Deiiang ISO 8 Hardwall Cleanrooms are designed in accordance with ISO 14644 cleanroom principles and can support GMP, pharmaceutical, medical device, electronics and other controlled-environment applications. Cleanroom classification, pressure, temperature, humidity and filtration requirements are confirmed according to the project specification. Relevant commissioning records and test documentation can be provided.

What tests are performed during ISO 8 Hardwall Cleanroom handover?

As-built handover testing may include airborne particle counting according to ISO 14644-1, HEPA filter integrity testing, airflow and air-change verification, differential pressure measurements, temperature and relative humidity monitoring, noise testing and smoke visualization where required. Calibration certificates for the measuring instruments can also be supplied.

What construction materials are used for ISO 8 Hardwall Cleanrooms?

ISO 8 Hardwall Cleanrooms typically use insulated sandwich panels with smooth, non-shedding and easy-to-clean surfaces, together with sealed joints, flush doors, viewing windows and ceiling-mounted terminal HEPA filter units. Panel cores, surface finishes, door hardware and accessories can be selected according to fire, thermal, corrosion-resistance and application requirements.

How does an ISO 8 Hardwall Cleanroom control contamination?

Contamination control is achieved through a sealed hardwall enclosure, controlled air changes, HEPA-filtered supply air and a positive pressure gradient relative to adjacent areas. The mixed or turbulent airflow pattern helps dilute and remove airborne particles. Smooth wall and floor interfaces, sealed penetrations and defined cleaning procedures further support stable cleanroom performance.

What maintenance and spare parts support does Deiiang provide?

Deiiang can provide preventive maintenance guidance and service support for ISO 8 Hardwall Cleanrooms, including inspection of panels, doors, seals, lighting, HVAC components and terminal filters. Spare pre-filters, HEPA filters, gaskets and other replacement parts can be supplied according to the installed system and maintenance schedule.

Can Deiiang provide validation documentation for ISO 8 Cleanroom audits?

Yes. Deiiang can provide project documentation such as layout and as-built drawings, equipment specifications, material information, operation and maintenance instructions, filter certificates, instrument calibration records, particle-count reports and commissioning or validation summaries. Documentation is prepared according to the agreed project scope and customer audit requirements.

ABOUT

Learn More About Deiiang Hardwall Cleanrooms

AdXvm-M2f-Y YouTube Video

Ventilation Times (ACH)

ISO ClassACH (Air Changes Per Hour)
ISO 3360 - 540
ISO 4300 - 540
ISO 5240 - 480
ISO 650 - 60
ISO 730 - 40
ISO 815 - 25
Certificate

CE Certificate for Deiiang Air Shower and HEPA Filters

Certificate

Electromagnetic Compatibility EMC Certification

Certificate

Filter CE-Certification

Deiiang Hardwall Cleanrooms Quality Control Flowchart

Cleanroom quality control flowchart

24-hour after-sales service commitment

Customer feedback reflects our value—take a look at what our customers say about our products and services.

Home

PHONE

Email

Inquiry