wap_menu MENU
X
Trusted by
companies like
FLIR Logo 1
electrolux Logo 3
abb Logo 4
bmw Logo 5
i-dent Logo 6
SINOPEC Logo 7
CATL Logo 8
INOVANCE Logo 9
EVE Logo 10
HONDA Logo 11
FOXCONN Logo 12

Particle Counter

Deiiang builds handheld and benchtop particle counters for ISO-classified and GMP cleanrooms. Every unit ships with a PSL-traceable ISO 21501-4 calibration certificate, and our engineers help you choose flow rate, channels and reporting to match your certification routine.

Particle Counter

Need a cleanroom particle counter solution?

Our professional team will provide you with customized cleanroom particle counter system solutions to meet your specific needs.

Types Of Deiiang Cleanroom Particle Counters

Deiiang cleanroom particle counters cover point checks and full-room certification in one range: 0.1 L/min micro-flow handhelds for isolators, 2.83 L/min handhelds for routine monitoring, and 28.3 L/min benchtops for ISO 14644-1 classification.
Five benchtop particle counters, 2.83 and 28.3 L/min, for ISO 14644-1 classification and GMP monitoring.
Check the details
Eleven handheld particle counters from 0.1 to 28.3 L/min for ISO 14644-1 point checks, monitoring rounds and cleanroom classification.
Check the details
An 8″ touchscreen, reference-grade optics, 28.3 L/min closed-loop flow and a full sampling kit: the APC-B330 is the instrument a certification body brings.
Check the details
Closed-loop flow held within 3%, an individually calibrated optical bench and the isokinetic probe, tripod and zero filter supplied as standard with the APC-B320.
Check the details
Audit trail with electronic signature, dual AC/DC supply and a printout carrying signature and date fields: the APC-B310 is built for regulated manufacturing.
Check the details
A 1 CFM benchtop with a 7″ display, built-in printer, 24 V battery pack and 100,000 records — classification volume without a cart and a generator.
Check the details
A 7″ touchscreen with counts, ISO class and 95% UCL on one screen, a built-in printer and 300 stored UCL sets — the APC-B200 for the fixed sampling point.
Check the details
A full 1 CFM in a handheld body: ISO 14644-1 volume for a Grade B point in under two minutes, with a built-in printer and 100,000 records.
Check the details
Particle count, PM2.5/PM10, formaldehyde, carbon monoxide, temperature and humidity from one probe — one record, one timestamp, no merging later.
Check the details
Six particle channels, a camera and a climate sensor in one handheld: every APC-H260 record carries a photograph plus temperature, RH, dew point and wet bulb.
Check the details
Flow held within 3%, a 50,000-hour laser and a per-channel calibration certificate: the APC-H250 is the handheld a calibration laboratory signs off on.
Check the details
A 3.5″ capacitive touchscreen that works through nitrile gloves, six particle channels plus PM2.5/PM10 mass, and a PDF report generated on board.
Check the details
One million records, seven hours per charge and six channels from 0.3 to 10 μm: the APC-H230 is built for daily monitoring rounds that never stop for a download.
Check the details
The APC-H220 prints a signed record at the sampling point on a built-in 58 mm thermal printer, keeps 100,000 records and runs eight hours per charge.
Check the details
The APC-H100 samples at 0.1 L/min so a Grade A zone is barely disturbed, counts six channels from 0.3 to 10 μm and stores about a million records.
Check the details
The APC-H050 reads PM2.5 and PM10 mass concentration plus temperature and humidity in one 250 g handheld, with 999 stored records and USB export.
Check the details
A piston pump holds 2.83 L/min through two metres of tubing, so the APC-H210 samples ducts, machine enclosures and remote points without losing the count on the way in.
Check the details
The APC-H200 handheld airborne particle counter samples 2.83 L/min across six channels from 0.3 to 10 μm, shows the ISO 14644-1 class on board and exports 10,000 records by USB or Bluetooth.
Check the details
ABOUT

Learn More About Deiiang Particle Counter

Aerial view of Deiiang Company
c2QUyz_yyR0 Cleanroom dust particle counter-DEMO APC B330 EN

Cleanroom dust particle counter-DEMO APC B330 EN

nfEd4Y1hm3Y Benchtop Particle Counter APC B320 EN

Benchtop Particle Counter APC B320 EN

p7gsk1H8DiM Benchtop Particle Counter APC B310 EN

Benchtop Particle Counter APC B310 EN

uvbneo33Pw4 Benchtop Airborne Particle Counter APC B300 EN

Benchtop Airborne Particle Counter APC B300 EN

Deiiang Particle Counter Quality Control Flowchart

Technical Resources

Total 0 resources

Handheld 0.1 CFM particle counter vs. Benchtop 1 CFM particle counter

Handheld 0.1 CFM cleanroom particle counter

Handheld 0.1 CFM particle counter
VS

Benchtop 1 CFM cleanroom particle counter

Benchtop 1 CFM particle counter

Handheld 0.1 CFM particle counter

A handheld 0.1 CFM (2.83 L/min) counter is what most QA teams carry on their rounds. It samples six channels from 0.3 to 10 μm, works out the ISO class on board, and lets you check a filling nozzle, an airlock or a return grille in a couple of minutes without planning a route. The limit is volume. One point check is fine; classifying a large room point by point will keep you sampling most of the day.

Benchtop 1 CFM particle counter

A benchtop 1 CFM (28.3 L/min) counter pulls ten times the air per minute, which is why certification bodies reach for it. One cubic foot per minute means a twenty-point Grade B grid can be finished in a shift, and the audit trail, printer and user levels are built in. The trade-off is that it stays where the sampling points are, so the survey is planned around the instrument.

Industry Applications

Deiiang cleanroom particle counter in Pharmaceutical & Biologics

Pharmaceutical & Biologics

On aseptic filling lines a handheld cleanroom particle counter confirms Grade A at the nozzle before each batch, and leaves a printable record for the inspector.

Send inquiry Now
Deiiang cleanroom particle counter in Semiconductors & Electronics

Semiconductors & Electronics

Wafer fabs run tighter particle budgets than most cleanrooms. Our counters verify ISO 5 zones around process tools and catch drift after maintenance, before yield feels it.

Send inquiry Now
Deiiang cleanroom particle counter in Hospitals & Operating Rooms

Hospitals & Operating Rooms

In theatres and isolation rooms staff need a fast airborne particle count before the first case. A 2.83 L/min handheld returns a result in about two minutes.

Send inquiry Now
Deiiang cleanroom particle counter in Medical Devices & Diagnostics

Medical Devices & Diagnostics

Sterile device assembly lives on validation schedules. Deiiang counters keep the routine monitoring log for ISO 8 rooms and support revalidation after a line change.

Send inquiry Now
Deiiang cleanroom particle counter in Food & Beverage Processing

Food & Beverage Processing

Aseptic filling and dairy packaging plants use a cleanroom particle counter to prove the enclosure still holds after CIP and before the next production run.

Send inquiry Now
Deiiang cleanroom particle counter in Aerospace & Precision Assembly

Aerospace & Precision Assembly

Satellite and optics assembly needs documented cleanliness. Our benchtop counters classify the room, and the printed record travels with the hardware.

Send inquiry Now

How to Work With Us

Customer feedback reflects our value—take a look at what our customers say about our products and services.

We bought the APC-H200 for filling line checks. The battery lasts a full shift, the ISO class comes up right on the screen, and QA accepted the printout without asking for a laptop export.

Marcus Feldt

Screen is bright and the buttons work with gloves on. Good unit for the price.

Priya Raghunathan

We ordered the 28.3 L/min benchtop for room certification. Finished a 24-point Grade B grid in one afternoon, report included. The audit trail was exactly what our inspector wanted to see.

Dr. Anneke de Vries

The calibration certificate and PSL data arrived with the instrument, which saved us an argument with the end customer's QA.

Tomás Ferreira

Works fine. I wish the manual explained the UCL settings better, but support answered within a day.

Kevin O'Donnell

Third counter we buy from Deiiang. The 0.1 L/min model is the only one small enough for our isolator glove ports without disturbing the airflow.

Sarah Whitfield
Frequently Asked Questions (FAQ)
What is a particle counter used for in a cleanroom?

It counts airborne particles by size so you can prove the room still meets its ISO class. The same measurement supports routine monitoring, HVAC troubleshooting and the classification report written after a build or a change.

Should I choose a 2.83 L/min or a 28.3 L/min particle counter?

A 2.83 L/min (0.1 CFM) handheld suits point checks and routine monitoring because it is small and quick. A 28.3 L/min (1 CFM) benchtop pulls ten times the air per minute, so it is the practical choice for classifying a whole room.

How often does a cleanroom particle counter need calibration?

Annually, against polystyrene latex spheres, following ISO 21501-4. If the instrument is dropped, repaired, or used in a heavily contaminated area, calibrate it sooner.

Can a handheld counter be used for formal ISO 14644-1 certification?

The counts are valid, but the standard sets a minimum sample volume per point and a minimum number of points. A 2.83 L/min unit reaches one cubic foot in about 21 minutes, so plan the survey around sample volume, not just the instrument.

What is 95% UCL and when do I need it?

When a room has fewer than ten sampling points, ISO 14644-1 asks for the upper confidence limit rather than a simple average. Our counters calculate it on board so the grade shown matches the report.

Do Deiiang counters meet EU GMP Annex 1 requirements?

They measure the six channels from 0.3 to 10 μm, including the ≥5.0 μm channel Annex 1 relies on for Grade A monitoring, and store the records with date, time, location and operator.

How to choose Particle Counter?

1

Flow Rate

Match the sampling volume to the job: 0.1 L/min for isolators and glove ports, 2.83 L/min for point checks, 28.3 L/min for classifying a room.

2

Size Channels

Six channels from 0.3 to 10 μm cover ISO 14644-1 and EU GMP Annex 1. Two-channel PM2.5/PM10 monitors are for screening, not certification.

3

Calibration

Ask for ISO 21501-4 calibration against PSL spheres and a certificate you can put in front of an auditor.

4

Reporting

Decide early whether you need printed records, an audit trail, or 21 CFR Part 11 electronic signatures.

5

Power & Memory

Daily rounds need all-day battery and large memory. Certification work can stay on mains power with a smaller log.

6

Sampling Kit

Check the accessories: isokinetic probe, tubing length you actually use, and a high-pressure diffuser for compressed gas.

7

After-sales

Annual calibration turnaround and spare inlet filters matter more than the purchase price once the unit is in service.

Follow these steps to choose the right cleanroom particle counter for your application

Home

PHONE

Email

Inquiry