3 ft DeskTop Horizontal Flow Clean Bench
Reference Price:US$from $200




Cleanroom
3 ft DeskTop Horizontal Flow Clean Bench
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
3 ft DeskTop Horizontal Flow Clean Bench
Validation
Installation & Validation
Product Briefing
The 3 ft Desktop Horizontal Flow Clean Bench is a compact, high-performance workstation designed for applications requiring a contamination-free environment. It features a horizontal laminar airflow system that directs HEPA-filtered air across the work surface, ensuring a sterile and particle-free workspace. Ideal for use in laboratories, electronics assembly, and other sensitive processes, this clean bench combines durability with ease of use, making it an essential tool for maintaining pristine conditions in critical tasks.
Applications:
Pharmaceuticals: Preparation and handling of sterile drugs.
Biotechnology: Tissue culture, media preparation, and other sensitive biological processes.
Electronics: Assembly and inspection of sensitive electronic components.
Research Laboratories: Conducting experiments requiring a contaminant-free environment.
Parameter table
Product Model | HD-650 single person, single-sided | HD-850 single person, single-sided |
airflow pattern | horizontal air supply | horizontal air supply |
Lighting lamps ultraviolet lamps | 10Wx①/10Wx① | 15Wx①/15Wx① |
Working size mm(LDH) | 490x480x480 | 680x440x480 |
Overall dimensions mm (LDH) | 620x520x830 | 820x520x830 |
Product Model | VD-650 single person, single-sided | VD-850 single person, single-sided |
airflow pattern | vertical air supply | vertical air supply |
Lighting lamps ultraviolet lamps | 10Wx①/10Wx① | 15Wx①/15Wx① |
Working size mm(LDH) | 490x480x480 | 680x440x480 |
Overall dimensions mm (LDH) | 620x520x830 | 820x520x830 |
Features
1. Portable,compact and flexible design.
2. Built-in tempered glass on both sides for easy observing.
3. Integrative stainless steel working tables corrosion-resistant, easy to clean.
4. High grade steel with static powder coating, well corrosion resistant ability, inhibiting bacterial growth effectively.
5. Streamline shape decrease interference of airflow.
6. Humanized pre-filters design make customers more convenient to change and clean.
7. Every clean bench is tested individually in according with international standard at factory forsafety and performance.
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
Stainless Steel Orifice Tabletop
ULPA Ultra GX Filter
UV Germicidal Lamps
De-static equipment
Support Stand with Caster Wheels
FAQ
1. What is a desktop horizontal flow clean bench?
A desktop horizontal flow clean bench is a compact workstation designed to provide a contamination-free environment by directing HEPA-filtered air horizontally across the work surface. It is commonly used in laboratories and cleanroom environments for tasks requiring a sterile workspace.
2. How does a desktop horizontal laminar flow hood work?
A desktop horizontal laminar flow hood operates by drawing air through a HEPA filter, which removes particles and contaminants. This filtered air is then directed horizontally across the work surface, creating a clean, particle-free environment that protects the work area from contamination.
3. What are the benefits of using a desktop horizontal flow clean bench?
The primary benefits of using a desktop horizontal flow clean bench include providing a sterile, particle-free work environment, enhancing product quality, and protecting sensitive materials from contamination. These benches are also compact, making them suitable for small workspaces.
4. How to maintain a desktop horizontal laminar flow hood?
Maintenance of a desktop horizontal laminar flow hood involves regular cleaning of the work surface and exterior, replacing pre-filters and HEPA filters as needed, and ensuring that the airflow remains consistent. Routine checks and professional servicing can prolong the equipment's lifespan and efficiency.
5. Can a desktop horizontal flow clean bench be used for microbiology?
Yes, a desktop horizontal flow clean bench can be used for microbiology. It provides a sterile environment that is essential for microbiological processes such as culturing, sample preparation, and other sensitive tasks that require contamination control.
6. What industries use desktop horizontal flow clean benches?
Industries that commonly use desktop horizontal flow clean benches include pharmaceuticals, biotechnology, electronics manufacturing, food processing, and research laboratories. These industries require contamination-free environments for various critical processes.
7. How to install a desktop horizontal laminar flow hood?
Installing a desktop horizontal laminar flow hood involves positioning the unit on a stable, level surface, connecting it to a power source, and ensuring proper airflow clearance around the unit. It is also important to follow the manufacturer's installation guidelines to ensure optimal performance.
8. What is the cost of a desktop horizontal flow clean bench?
The cost of a desktop horizontal flow clean bench can vary widely depending on size, features, and manufacturer. On average, prices range from a few hundred to several thousand dollars, with more advanced models costing more due to additional features and higher quality components.
9. How often should HEPA filters be replaced in a desktop horizontal flow clean bench?
HEPA filters in a desktop horizontal flow clean bench should typically be replaced every 1 to 3 years, depending on usage and environmental conditions. Regular monitoring and performance testing can help determine the optimal replacement schedule.
10. What is the difference between a desktop horizontal and vertical laminar flow hood?
The main difference between a desktop horizontal and vertical laminar flow hood is the direction of airflow. In a horizontal flow hood, air is directed horizontally across the work surface, while in a vertical flow hood, air flows vertically from the top down. Each type offers different benefits depending on the application.
11. Can a desktop horizontal flow clean bench protect against viruses?
A desktop horizontal flow clean bench can protect against viruses to a certain extent by providing a sterile environment and filtering out airborne particles. However, it is not a substitute for biosafety cabinets, which are specifically designed for handling pathogenic microorganisms and providing operator protection.
12. What materials are used to construct a desktop horizontal flow clean bench?
A desktop horizontal flow clean bench is typically constructed using durable materials such as stainless steel for the work surface, aluminum or steel for the frame, and glass or acrylic for the enclosure. These materials are chosen for their strength, ease of cleaning, and resistance to contamination.
13. How effective are HEPA filters in a desktop horizontal laminar flow hood?
HEPA filters in a desktop horizontal laminar flow hood are highly effective, capable of removing at least 99.97% of airborne particles as small as 0.3 microns. This level of filtration ensures a clean, particle-free environment for sensitive tasks.
14. What is the power requirement for a desktop horizontal flow clean bench?
The power requirement for a desktop horizontal flow clean bench typically ranges from 110 to 240 volts, depending on the model and manufacturer. It is important to check the specific power requirements of the unit to ensure compatibility with the available power source.
15. What is the airflow velocity in a desktop horizontal flow clean bench?
The airflow velocity in a desktop horizontal flow clean bench usually ranges from 0.3 to 0.5 meters per second (m/s). This velocity ensures a consistent and uniform flow of clean air across the work surface, maintaining a contamination-free environment.
16. How to clean a desktop horizontal laminar flow hood?
Cleaning a desktop horizontal laminar flow hood involves using a lint-free cloth and a suitable disinfectant to wipe down all accessible surfaces, including the work surface, walls, and glass panels. It is important to follow the manufacturer's guidelines and avoid using abrasive cleaners that could damage the unit.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set