8 ft Medical Clean bench-Vertical Flow

Reference Price:US$From $1800

Short Description:

An 8 ft medical clean bench is a large, sterile workspace designed to provide a clean, particle-free environment for medical and laboratory procedures. It features high-efficiency particulate air (HEPA) filters,

  • Air Flow: Vertical flow
  • Available sizes: 8 ft
  • size: 2400×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: Hepa Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

8 ft Medical Clean bench-Vertical Flow

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

8 ft Medical Clean bench-Vertical Flow

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

An 8 ft medical clean bench is a large, sterile workspace designed to provide a clean, particle-free environment for medical and laboratory procedures. It features high-efficiency particulate air (HEPA) filters, adjustable airflow, and ample workspace to accommodate various tasks, ensuring the safety and integrity of sensitive operations.Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. What are the benefits of using a vertical laminar flow cabinet in a lab?

Using a vertical laminar flow cabinet in a lab offers numerous benefits including maintaining a sterile environment, reducing the risk of contamination, and protecting both samples and operators from airborne contaminants. These cabinets are essential for ensuring the integrity of sensitive experiments and procedures.


2. What are the applications of a medical clean bench?

Medical clean benches are widely used in various applications such as preparing sterile solutions, conducting microbiological tests, and handling sensitive samples. They are essential in environments where a contamination-free workspace is crucial, such as hospitals, research labs, and pharmaceutical industries.


3. What are the common contaminants in a medical clean bench?

Common contaminants in a medical clean bench include dust particles, microorganisms, and chemical vapors. These contaminants can compromise the sterility of the workspace and affect the quality of procedures carried out in the bench.


4. How to upgrade an existing vertical laminar flow cabinet?

Upgrading an existing vertical laminar flow cabinet involves installing new HEPA or ULPA filters, upgrading the airflow system, and integrating advanced control systems for better monitoring. Regular maintenance and replacing worn-out parts can also improve the performance and lifespan of the cabinet.


5. What are the specifications for a high-quality vertical laminar flow cabinet?

A high-quality vertical laminar flow cabinet features HEPA or ULPA filters, adjustable airflow velocity, low noise levels, and an ergonomic design. It should also have a durable construction, easy-to-clean surfaces, and advanced control systems for monitoring airflow and filter status.


6. How to improve lighting in a medical clean bench?

To improve lighting in a medical clean bench, install high-intensity LED lights that provide bright, even illumination. Ensure the lighting is positioned to minimize shadows and reflections, enhancing visibility and reducing eye strain during precise tasks.


7. How to choose between a medical clean bench and a biosafety cabinet?

Choosing between a medical clean bench and a biosafety cabinet depends on the level of protection required. A medical clean bench provides a sterile workspace but does not protect the user from harmful agents, while a biosafety cabinet offers both product and personal protection, making it suitable for handling hazardous materials.


8. How to ensure optimal performance of a medical clean bench?

To ensure optimal performance of a medical clean bench, regularly check and replace HEPA filters, clean the work surface frequently, and conduct routine airflow tests. Proper training for users on correct operation and maintenance procedures is also essential.


9. How to train staff to use a medical clean bench?

Training staff to use a medical clean bench involves providing comprehensive instruction on its operation, maintenance, and safety protocols. Hands-on demonstrations and regular refresher courses can help ensure that staff are proficient and confident in using the equipment correctly.


10. What are the power requirements for a vertical laminar flow cabinet?

The power requirements for a vertical laminar flow cabinet typically range between 110-240 volts, depending on the model and manufacturer. It's essential to ensure that the power supply is stable and meets the specifications provided by the manufacturer to avoid any electrical issues.


11. What is the importance of laminar flow in a clean bench?

Laminar flow in a clean bench is crucial as it ensures a consistent, unidirectional airflow that prevents cross-contamination and maintains a sterile environment. This controlled airflow is essential for protecting sensitive samples and ensuring the validity of experimental results.


12. How to properly clean a medical clean bench?

Properly cleaning a medical clean bench involves using disinfectants to wipe down all surfaces, including the work area, walls, and any equipment inside the bench. Regular cleaning, along with periodic deep cleaning, helps maintain sterility and prevent contamination.


13. How to test the effectiveness of a vertical laminar flow cabinet?

To test the effectiveness of a vertical laminar flow cabinet, perform a particle count test using a particle counter. This test measures the number of particles in the air before and after filtration, ensuring the cabinet meets cleanliness standards.


14. What are the guidelines for using a medical clean bench?

Guidelines for using a medical clean bench include ensuring proper airflow, regularly replacing filters, and maintaining cleanliness. Users should also follow specific protocols for handling materials and avoid introducing contaminants into the workspace.


15. How to conduct a visual inspection of a medical clean bench?

Conducting a visual inspection of a medical clean bench involves checking for any visible damage, ensuring the filters are intact and clean, and verifying that all components are functioning correctly. Regular inspections help identify potential issues early and maintain performance.


16. How to ensure consistent airflow in a vertical laminar flow cabinet?

To ensure consistent airflow in a vertical laminar flow cabinet, regularly clean and replace filters, perform routine maintenance checks, and ensure the fan and motor are functioning properly. Monitoring airflow patterns can also help detect and address any disruptions.


17. What are the common issues with medical clean benches?

Common issues with medical clean benches include inconsistent airflow, clogged filters, and excessive noise levels. Regular maintenance, including cleaning and replacing filters, is essential to address these issues and ensure optimal performance.


18. What are the ergonomic considerations for using a medical clean bench?

Ergonomic considerations for using a medical clean bench include adjustable seating, proper height of the work surface, and adequate lighting. These factors help reduce strain and improve comfort for users, enhancing productivity and reducing the risk of injury.


19. How to improve air quality in a vertical laminar flow cabinet?

Improving air quality in a vertical laminar flow cabinet involves regularly replacing HEPA filters, ensuring proper airflow, and conducting routine maintenance. Keeping the workspace clean and free from contaminants is also crucial for maintaining high air quality.


20. What accessories are available for medical clean benches?

Accessories available for medical clean benches include UV sterilization lights, ergonomic seating, adjustable shelving, and additional filtration units. These accessories enhance functionality, comfort, and the overall efficiency of the workspace.


21. What is the warranty period for a vertical laminar flow cabinet?

The warranty period for a vertical laminar flow cabinet typically ranges from one to five years, depending on the manufacturer and model. It's important to review the warranty terms and conditions to understand what is covered and any maintenance requirements.


22. How to measure airflow in a vertical laminar flow cabinet?

To measure airflow in a vertical laminar flow cabinet, use an anemometer to check the velocity of the air at various points within the cabinet. Consistent airflow readings ensure the cabinet is operating correctly and maintaining the required sterile environment.


23. How to troubleshoot a medical clean bench?

Troubleshooting a medical clean bench involves checking for common issues such as inconsistent airflow, clogged filters, and electrical problems. Refer to the manufacturer's manual for specific troubleshooting steps and, if necessary, consult with a professional technician.


24. Can a vertical laminar flow cabinet be used for vaccine production?

Yes, a vertical laminar flow cabinet can be used for vaccine production. It provides a sterile environment essential for handling and preparing vaccines, ensuring that the product remains uncontaminated throughout the production process.

Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.