1` FYCLS negative pressure raw material sampling room-PLC control, touch screen, polymer equalization membrane

Reference Price:US$

Min. Order:

Short Description:

Neg Furls Negative Pressure Weighing Chamber is an advanced localized purification equipment widely used in the fields of pharmaceuticals, microbiological research and scientific experiments.

  • Worktop Material:
  • sizes:
  • widths:
  • depths:
  • Front window opening height:
  • Power Adaptation:
  • noise:
  • lights:
  • exhaust volume:
  • surface air velocity:
  • production state:
  • customs code:
  • Product Certification:
  • Applicable area:

Cleanroom

1` FYCLS negative pressure raw material sampling room-PLC control, touch screen, polymer equalization membrane

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

1` FYCLS negative pressure raw material sampling room-PLC control, touch screen, polymer equalization membrane

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Detail

Neg Furls Negative Pressure Weighing Chamber is an advanced localized purification equipment widely used in the fields of pharmaceuticals, microbiological research and scientific experiments. The unique vertical unidirectional airflow design ensures a high degree of cleanliness in the working area and prevents cross contamination. With a highly efficient dust removal system and easy operation, the Neg Furls Negative Pressure Weighing Chamber provides a reliable solution for handling dust particles in a variety of industries, ensuring safe and efficient experimental processes. With a deeper understanding of its working principle, users can fully utilize its important role in all kinds of experiments.


Negative Pressure Weighing Chamber SpecificationsKLDC-FYCLS 1200
KLDC-FYCLS 1300KLDC-FYCLS 1400
KLDC-FYCLS 1500KLDC-FYCLS 1600KLDC-FYCLS 2700
Overall Dimension(mm)1200X1200x25001300X1300X25001500x1300X25002000x1300Xx25002000X1500X25002000x1800X2500
Size of working area (mm)1100X700X20001200x800X20001400X700X20001900x800X20001900X1000X20001900X1300X2000
Rated air volume (m°/h)1300~15001600~18002000~22002500~27003400-36004500~4900
Wind speed (m/s)0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%
cleanliness levelA级A级A级A级A级A级
Noise (dB)727272727272
Illumination (Lux)>300>300>300>300>300>300
control method

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Power (KW)0.750.751.51.52.22.2


Note: Negative pressure weighing room can be made according to customer requirements for non-standard products. 

Specification

Neg Furls Negative Pressure Weighing Chambers provide total safety and an efficient operating experience in laboratory and industrial environments due to their superior design and advanced technology.

  • Unique Air Duct Design

The Neg Furls Negative Pressure Weighing Chamber utilizes a unique air duct design that reduces noise during operation and provides a quieter working environment. This design also optimizes air flow and ensures stable airflow inside the unit.

  • Equalized flow design for safety

The unique equalized flow design in the main working area allows for effective control of dust and reagent spillage and uplift when weighing and dispensing in the equipment. This not only prevents dust and reagents from being inhaled by the human body and reduces health risks, but also avoids cross contamination of dust and reagents and protects the outside environment and the safety of the people inside. The weighing operation area is protected by a Class 100 vertical layer IS06 (NF, EN, IS0014644-1), ensuring a highly clean operating environment.

  • Highly efficient filtration and precise control

The negative pressure weighing chamber consists of a variety of high-efficiency components, including the chassis, air supply high-efficiency filters, exhaust high-efficiency filters, variable air volume fan set, PLC control system and sensing system. The chassis is made of brushed fingerprint-free stainless steel SUS304 with one-piece bending process, which is beautiful, clean and easy to clean, and greatly facilitates daily maintenance.

  • Advanced control system

The combination of PLC control system and sensing system enables the unit to monitor and adjust the internal environment in real time, ensuring the accuracy and safety of operation. Variable air volume fan units automatically adjust the air volume according to the demand, further improving the energy efficiency and stability of the equipment.

The Neg Furls Negative Pressure Weighing Chamber provides a safe, efficient and quiet operating environment through its unique design and efficient features, making it ideal for dust and reagent handling in laboratory and industrial environments.


Neg Furls Negative Pressure Weighing Chamber ensures an efficient and safe weighing environment with its superior materials and advanced design.

  • Frequency control: The negative pressure weighing chamber adopts common control system with optional LCD display and operation interface, providing real-time wind speed display and setting alarm function to ensure the accuracy and safety of operation.

  • Cabinet: The negative pressure weighing chamber's cabinet is made of SUS304 stainless steel, which is carefully crafted through bending, welding and assembling process, with high flatness, easy to clean and maintain. The design of the electrical cabinet is flexible, and users can choose built-in or external installation according to their needs, which further enhances the operation convenience and safety.

  • Polymer Even Flow Membrane: The air outlet surface is made of polymer even flow membrane, which can control the evenness of wind speed between 5% and 10%, greatly improving the evenness of air outlet. This design not only effectively improves the air circulation effect, but also significantly improves the operation efficiency of the whole system.

With its high quality materials and innovative design, the Neg Furls Negative Pressure Weighing Chamber provides users with an efficient and safe operating environment, making it an ideal choice for laboratories and industry.

负压称量室配置图


Principle

Neg Furls Negative Pressure Weighing Chambers provide total safety and an efficient operating experience in laboratory and industrial environments due to their superior design and advanced technology.

Unique Air Duct Design

The Neg Furls Negative Pressure Weighing Chamber utilizes a unique air duct design that reduces noise during operation and provides a quieter working environment. This design also optimizes air flow and ensures stable airflow inside the unit.

Equalized flow design for safety

The unique equalized flow design in the main working area allows for effective control of dust and reagent spillage and uplift when weighing and dispensing in the equipment. This not only prevents dust and reagents from being inhaled by the human body and reduces health risks, but also avoids cross contamination of dust and reagents and protects the outside environment and the safety of the people inside. The weighing operation area is protected by a Class 100 vertical layer IS06 (NF, EN, IS0014644-1), ensuring a highly clean operating environment.

Highly efficient filtration and precise control

The negative pressure weighing chamber consists of a variety of high-efficiency components, including the chassis, air supply high-efficiency filters, exhaust high-efficiency filters, variable air volume fan set, PLC control system and sensing system. The chassis is made of brushed fingerprint-free stainless steel SUS304 with one-piece bending process, which is beautiful, clean and easy to clean, and greatly facilitates daily maintenance.

Advanced control system

The combination of PLC control system and sensing system enables the unit to monitor and adjust the internal environment in real time, ensuring the accuracy and safety of operation. Variable air volume fan units automatically adjust the air volume according to the demand, further improving the energy efficiency and stability of the equipment.

The Neg Furls Negative Pressure Weighing Chamber provides a safe, efficient and quiet operating environment through its unique design and efficient features, making it ideal for dust and reagent handling in laboratory and industrial environments.

负压称量室原理图


Accessories

Options. 



1


Wind Speed Sensor 

风速传感器


2


Differential Pressure Sensor 

压差传感器


3


converter

微信截图_20240626191907.jpg


4


touchscreens

触摸屏


5


PLC control

PLC控制系统


6


 Polymer homogeneous membrane

 高分子均流膜



Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.