GDC™ Auto Sensor Air Shower - 1400(W)x1000(D)x2200(H)

Reference Price:US$1200.00-1800.00

Short Description:

GDC™ automatic assembly line goods shower room (goods shower room or air shower channel) air shower room is a kind of local purification equipment with strong versatility, installed in the clean room and non-clean room between.

  • External dimension: 1400*1000*2200
  • inner dimension: 800*900*1960
  • material: 304 stainless steel
  • Number of applicants: 1
  • thicknesses: 1.0mm
  • Number of fans: 2 sets*0.55Kw/set
  • Number of nozzles: 12
  • door closer: “Dorma“
  • electronic lock: “Luxgen” electric locks
  • weights: 350kg
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Product Certification: ASHRAE 110 ASTM E84 CAN/CSA C22.2 CE NFPA 45
  • customs code: 43534654

Select your requirements for air shower materials

  • Quantity:

Choose your Plate Thickness Requirements

  • Quantity:

Select your local supply voltage

  • Quantity:

Summary

Air Shower

GDC™ Auto Sensor Air Shower - 1400(W)x1000(D)x2200(H)

Choose your upgrade options

Air Shower Detail

The Auto Sensor Air Shower is a high-efficiency cleanroom equipment designed to remove particulate matter and contaminants from personnel and materials before they enter clean environments. Equipped with advanced sensor technology, the Auto Sensor Air Shower automatically detects the presence of personnel or objects, initiating and ceasing the air shower process to ensure efficient and energy-saving operation.

Deiiang air shower playbill.jpg

Features

  • Automatic Sensing: Infrared/ultrasonic sensors for automatic operation

  • High-Efficiency Filtration: HEPA/ULPA filters capture 99.97%+ particles ≥ 0.3 microns

  • Programmable Control: Touchscreen/PLC for setting parameters

  • Omnidirectional Nozzles: Multi-angle, high-velocity air jets

  • Emergency Stop: Immediate cessation for safety

  • Stainless Steel: Durable, corrosion-resistant construction

  • Interlocking Doors: Prevents cross-contamination

  • Low-Noise Design: Quiet operation for user comfort

Industry Applications

  • Electronics Manufacturing: Semiconductor and microelectronics

  • Pharmaceuticals: Drug manufacturing and packaging

  • Food Processing: High hygiene standards in production

  • Biotechnology: Labs and production facilities

  • Aerospace: Manufacturing and assembly

  • Automotive: Painting and assembly processes

Stainless steel air shower room10.jpg

Stainless steel air shower room6.jpg

Stainless steel air shower room9.jpg


Air shower room details2.jpg

Air shower room details1.jpg

Air Shower Parameter

Indicator Model 1`Purifier STD 2`Purifier STD 3`Purifier STD 4`Purifier STD 5`Purifier STD
Material Selection


1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel

SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot)

Number of applicants

1 person

2 persons (affordable)

3.4 persons (2 persons standard)

3.4 persons (3 persons standard) 6.8 persons (4 persons standard)
Number of nozzles 12 (bilateral) 18 (bilateral) 24 (bilateral) 36 (bilateral) 48 (bilateral)
Air velocity 24-30m/s 24-30m/s 24-30m/s 24-30m/s 24-30m/s
Electronic lock brand "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks
Efficient size 600x600x120mm 820x600x120mm

600x600x120mm

600x600x120mm

600x600x120mm
Overall Dimension 1400W*1000D*2100H 1400W*1500D*2100H 1400W*2000D*2100H 1400W*3000D*2100H 1400W*4000D*2100H
Internal dimensions 800w*900D*1960H 800w*1400D*1960H 800w*1900D*1960H 800w*2900D*1960H 800w*3900D*1960H
power supply

380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground).

The air shower room can be customized with 220V and 110V power supply according to customers' requirements.)

Lighting LED recessed light 1pc LED recessed light 2pc LED recessed light 2pc LED recessed light 3pc LED recessed light 4pc
Number of fans

2 sets "0.55Kw/set

2 sets~0.75KW/set

4 units "0.55Kw/unit

6 sets "0.55KW/set

8 units*0.55Kw/unit
Power of the whole machine

1.1Kw

1.5Kw

2.2Kw

3.3Kw 4.4Kw
Stall capacity (kg) 350kg

500kg

650kg

950kg 1250kg
Indicator Model 1`Purifier STD 2`Purifier STD 3`Purifier STD
Material Selection


1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel

SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot)

Number of applicants

1 person

2 persons (affordable)

3.4 persons (2 persons standard)

Number of nozzles 12 (bilateral) 18 (bilateral) 24 (bilateral)
Air velocity 24-30m/s 24-30m/s 24-30m/s
Electronic lock brand "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks
Efficient size 600x600x120mm 820x600x120mm

600x600x120mm

Overall Dimension 1400W*1000D*2100H 1400W*1500D*2100H 1400W*2000D*2100H
Internal dimensions 800w*900D*1960H 800w*1400D*1960H 800w*1900D*1960H
power supply

380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground).

The air shower room can be customized with 220V and 110V power supply according to customers' requirements.)

Lighting LED recessed light 1pc LED recessed light 2pc LED recessed light 2pc
Number of fans

2 sets "0.55Kw/set

2 sets~0.75KW/set

4 units "0.55Kw/unit

Power of the whole machine

1.1Kw

1.5Kw

2.2Kw

Stall capacity (kg) 350kg

500kg

650kg

Indicator Model 3`Purifier STD 4`Purifier STD 5`Purifier STD
Material Selection

1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel

SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot)

Number of applicants

3.4 persons (2 persons standard)

3.4 persons (3 persons standard) 6.8 persons (4 persons standard)
Number of nozzles 24 (bilateral) 36 (bilateral) 48 (bilateral)
Air velocity 24-30m/s 24-30m/s 24-30m/s
Electronic lock brand "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks
Efficient size

600x600x120mm

600x600x120mm

600x600x120mm
Overall Dimension 1400W*2000D*2100H 1400W*3000D*2100H 1400W*4000D*2100H
Internal dimensions 800w*1900D*1960H 800w*2900D*1960H 800w*3900D*1960H
power supply

380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground).

The air shower room can be customized with 220V and 110V power supply according to customers' requirements.)

Lighting LED recessed light 2pc LED recessed light 3pc LED recessed light 4pc
Number of fans

4 units "0.55Kw/unit

6 sets "0.55KW/set

8 units*0.55Kw/unit
Power of the whole machine

2.2Kw

3.3Kw 4.4Kw
Stall capacity (kg)

650kg

950kg 1250kg

Air Shower Structure

Stainless steel air shower room configuration structure

Air shower room structure diagram.jpg

  • Top cover

  • Door closer

  • Suction cup lock

  • Lighting

  • Control panel

  • Emergency switch

  • Stainless steel door

  • Stainless steel nozzle

  • High efficiency filter

  • Box

  • Primary filter

  • Specialized fan

  • Stainless steel chassis

Air Shower Usage

Air Shower Room Operation Steps

How to use the air shower

Prepare:

  • Ensure you are properly attired in cleanroom garments.

  • Verify that the air shower is operational.

Enter:

  • Step into the air shower room and close the door behind you.

  • Stand in the designated area and remain still.

Activate:

  • Wait for the air shower cycle to start automatically.

  • The air jets will begin, removing contaminants.

Exit:

  • After the cycle completes, open the exit door.


FAQ

1. How to measure air shower performance?

To measure air shower performance, you should monitor key metrics such as airflow velocity, particle removal efficiency, and cycle time. Regular testing and calibration using particle counters and anemometers ensure the system operates within optimal parameters.


2. How to troubleshoot air shower blower issues?

To troubleshoot air shower blower issues, start by checking the power supply and electrical connections. Inspect the blower motor for any signs of wear or damage. If the blower is still not functioning correctly, it may require professional servicing.


3. How to address air shower malfunctions?

Addressing air shower malfunctions involves identifying the issue through thorough inspection, repairing or replacing faulty components, and retesting the system to ensure it functions correctly. Regular maintenance can help prevent future malfunctions.


4. What training is required for air shower operation?

Training for air shower operation includes familiarizing personnel with the system’s controls, proper entry and exit procedures, and routine maintenance checks. Staff should also be trained on emergency protocols in case of system failure.


5. How to integrate air showers into a production line?

Integrating air showers into a production line requires strategic placement to minimize workflow disruption, ensuring sufficient space for installation, and coordinating with production schedules. Consulting with experts can facilitate a smooth integration process.


6. What are the guidelines for air shower use in research facilities?

Guidelines for air shower use in research facilities include:

  • Regularly cleaning and maintaining the unit

  • Ensuring proper usage by trained personnel

  • Conducting routine performance tests

These practices help maintain a contamination-free environment for sensitive research activities.


7. How to ensure air shower compliance with health regulations?

Ensuring air shower compliance with health regulations involves adhering to industry standards, conducting regular inspections, and maintaining detailed records of maintenance and performance tests. Consulting with regulatory experts can help navigate specific requirements.


8. How to ensure consistent performance of air showers?

To ensure consistent performance of air showers, conduct regular maintenance, including cleaning and replacing filters, calibrating airflow settings, and inspecting mechanical components. Staff training on proper usage also plays a crucial role.


9. What are the latest advancements in air shower technology?

Recent advancements in air shower technology include improved HEPA filter efficiency, automated control systems for better monitoring and maintenance, and energy-efficient blowers. These innovations enhance performance and reduce operational costs.


10. How to handle air shower emergency situations?

Handling air shower emergency situations involves:

  • Training staff on emergency protocols

  • Providing clear instructions for manual override

  • Regularly testing emergency systems

These measures ensure quick and effective responses to any issues.


11. What are the installation requirements for air showers?

Installation requirements for air showers include adequate space for the unit, proper electrical connections, and ensuring that the location supports the weight and structural dimensions of the air shower. Consulting with installation experts ensures compliance with these requirements.


12. What are the safety features of an automatic assembly line air shower?

Safety features of an automatic assembly line air shower include interlocking doors to prevent contamination, emergency stop buttons, and automated cycle controls to ensure consistent decontamination processes. These features enhance operational safety and efficiency.


13. How to maintain the blower in an air shower?

Maintaining the blower in an air shower involves regular inspection for wear and tear, cleaning or replacing filters, and ensuring proper lubrication of moving parts. Scheduled maintenance checks can prevent blower failures and extend its lifespan.


14. How to integrate air showers into a warehouse setting?

Integrating air showers into a warehouse setting involves assessing the flow of goods and personnel, ensuring sufficient space for installation, and coordinating with warehouse operations to minimize disruption. Custom solutions may be required for optimal integration.


15. How to ensure air shower system compatibility?

Ensuring air shower system compatibility involves:

  • Assessing existing infrastructure

  • Consulting with manufacturers for customized solutions

  • Verifying electrical and spatial requirements

These steps ensure the new system integrates seamlessly with current operations.


16. How to manage air shower noise levels?

Managing air shower noise levels can be achieved by using sound-dampening materials, regular maintenance of blower units, and ensuring proper installation to minimize vibration. Noise reduction measures enhance the working environment for personnel.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.