GDC™ Auto Sensor Air Shower - 1400(W)x1000(D)x2200(H)
Reference Price:US$1200.00-1800.00






Select your requirements for air shower materials
Quantity:
Choose your Plate Thickness Requirements
Quantity:
Select your local supply voltage
Quantity:
Summary
GDC™ Auto Sensor Air Shower - 1400(W)x1000(D)x2200(H)
Find Similar Products
-
GDC™ Auto Sensor Air Shower - 1400(W)x2000(D)x2200(H)
US$1000.00-5000.00
Min. Order:1 unit -
GDC™ Auto Sensor Air Shower - 1400(W)x1500(D)x2200(H)
US$1000.00-5000.00
Min. Order:1 unit -
GDC™ Auto Sensor Air Shower - 1400(W)x1000(D)x2200(H)
US$1000.00-5000.00
Min. Order:1 unit -
GDC™ Auto Sensor Air Shower - 1200(W)x3000(D)x2200(H)
US$1000.00-5000.00
Min. Order:1 unit -
GDC™ Auto Sensor Air Shower - 1200(W)x2000(D)x2200(H)
US$1000.00-5000.00
Min. Order:1 unit -
GDC™ Auto Sensor Air Shower - 1200(W)x1500(D)x2200(H)
US$1000.00-5000.00
Min. Order:1 unit
Air Shower Detail
The Auto Sensor Air Shower is a high-efficiency cleanroom equipment designed to remove particulate matter and contaminants from personnel and materials before they enter clean environments. Equipped with advanced sensor technology, the Auto Sensor Air Shower automatically detects the presence of personnel or objects, initiating and ceasing the air shower process to ensure efficient and energy-saving operation.
Features
Automatic Sensing: Infrared/ultrasonic sensors for automatic operation
High-Efficiency Filtration: HEPA/ULPA filters capture 99.97%+ particles ≥ 0.3 microns
Programmable Control: Touchscreen/PLC for setting parameters
Omnidirectional Nozzles: Multi-angle, high-velocity air jets
Emergency Stop: Immediate cessation for safety
Stainless Steel: Durable, corrosion-resistant construction
Interlocking Doors: Prevents cross-contamination
Low-Noise Design: Quiet operation for user comfort
Industry Applications
Electronics Manufacturing: Semiconductor and microelectronics
Pharmaceuticals: Drug manufacturing and packaging
Food Processing: High hygiene standards in production
Biotechnology: Labs and production facilities
Aerospace: Manufacturing and assembly
Automotive: Painting and assembly processes
Air Shower Parameter
Indicator Model | 1`Purifier STD | 2`Purifier STD | 3`Purifier STD | 4`Purifier STD | 5`Purifier STD |
---|---|---|---|---|---|
Material Selection |
1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot) |
||||
Number of applicants |
1 person |
2 persons (affordable) |
3.4 persons (2 persons standard) |
3.4 persons (3 persons standard) | 6.8 persons (4 persons standard) |
Number of nozzles | 12 (bilateral) | 18 (bilateral) | 24 (bilateral) | 36 (bilateral) | 48 (bilateral) |
Air velocity | 24-30m/s | 24-30m/s | 24-30m/s | 24-30m/s | 24-30m/s |
Electronic lock brand | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks |
Efficient size | 600x600x120mm | 820x600x120mm |
600x600x120mm |
600x600x120mm |
600x600x120mm |
Overall Dimension | 1400W*1000D*2100H | 1400W*1500D*2100H | 1400W*2000D*2100H | 1400W*3000D*2100H | 1400W*4000D*2100H |
Internal dimensions | 800w*900D*1960H | 800w*1400D*1960H | 800w*1900D*1960H | 800w*2900D*1960H | 800w*3900D*1960H |
power supply |
380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground). The air shower room can be customized with 220V and 110V power supply according to customers' requirements.) |
||||
Lighting | LED recessed light 1pc | LED recessed light 2pc | LED recessed light 2pc | LED recessed light 3pc | LED recessed light 4pc |
Number of fans |
2 sets "0.55Kw/set |
2 sets~0.75KW/set |
4 units "0.55Kw/unit |
6 sets "0.55KW/set |
8 units*0.55Kw/unit |
Power of the whole machine |
1.1Kw |
1.5Kw |
2.2Kw |
3.3Kw | 4.4Kw |
Stall capacity (kg) | 350kg |
500kg |
650kg |
950kg | 1250kg |
Indicator Model | 1`Purifier STD | 2`Purifier STD | 3`Purifier STD |
---|---|---|---|
Material Selection |
1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot) |
||
Number of applicants |
1 person |
2 persons (affordable) |
3.4 persons (2 persons standard) |
Number of nozzles | 12 (bilateral) | 18 (bilateral) | 24 (bilateral) |
Air velocity | 24-30m/s | 24-30m/s | 24-30m/s |
Electronic lock brand | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks |
Efficient size | 600x600x120mm | 820x600x120mm |
600x600x120mm |
Overall Dimension | 1400W*1000D*2100H | 1400W*1500D*2100H | 1400W*2000D*2100H |
Internal dimensions | 800w*900D*1960H | 800w*1400D*1960H | 800w*1900D*1960H |
power supply |
380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground). The air shower room can be customized with 220V and 110V power supply according to customers' requirements.) |
||
Lighting | LED recessed light 1pc | LED recessed light 2pc | LED recessed light 2pc |
Number of fans |
2 sets "0.55Kw/set |
2 sets~0.75KW/set |
4 units "0.55Kw/unit |
Power of the whole machine |
1.1Kw |
1.5Kw |
2.2Kw |
Stall capacity (kg) | 350kg |
500kg |
650kg |
Indicator Model | 3`Purifier STD | 4`Purifier STD | 5`Purifier STD |
---|---|---|---|
Material Selection |
1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot) |
||
Number of applicants |
3.4 persons (2 persons standard) |
3.4 persons (3 persons standard) | 6.8 persons (4 persons standard) |
Number of nozzles | 24 (bilateral) | 36 (bilateral) | 48 (bilateral) |
Air velocity | 24-30m/s | 24-30m/s | 24-30m/s |
Electronic lock brand | "Luxgen" electric locks | "Luxgen" electric locks | "Luxgen" electric locks |
Efficient size |
600x600x120mm |
600x600x120mm |
600x600x120mm |
Overall Dimension | 1400W*2000D*2100H | 1400W*3000D*2100H | 1400W*4000D*2100H |
Internal dimensions | 800w*1900D*1960H | 800w*2900D*1960H | 800w*3900D*1960H |
power supply |
380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground). The air shower room can be customized with 220V and 110V power supply according to customers' requirements.) |
||
Lighting | LED recessed light 2pc | LED recessed light 3pc | LED recessed light 4pc |
Number of fans |
4 units "0.55Kw/unit |
6 sets "0.55KW/set |
8 units*0.55Kw/unit |
Power of the whole machine |
2.2Kw |
3.3Kw | 4.4Kw |
Stall capacity (kg) |
650kg |
950kg | 1250kg |
Air Shower Structure
Stainless steel air shower room configuration structure
Top cover
Door closer
Suction cup lock
Lighting
Control panel
Emergency switch
Stainless steel door
Stainless steel nozzle
High efficiency filter
Box
Primary filter
Specialized fan
Stainless steel chassis
Air Shower Usage
Air Shower Room Operation Steps
Prepare:
Ensure you are properly attired in cleanroom garments.
Verify that the air shower is operational.
Enter:
Step into the air shower room and close the door behind you.
Stand in the designated area and remain still.
Activate:
Wait for the air shower cycle to start automatically.
The air jets will begin, removing contaminants.
Exit:
After the cycle completes, open the exit door.
FAQ
1. How to measure air shower performance?
To measure air shower performance, you should monitor key metrics such as airflow velocity, particle removal efficiency, and cycle time. Regular testing and calibration using particle counters and anemometers ensure the system operates within optimal parameters.
2. How to troubleshoot air shower blower issues?
To troubleshoot air shower blower issues, start by checking the power supply and electrical connections. Inspect the blower motor for any signs of wear or damage. If the blower is still not functioning correctly, it may require professional servicing.
3. How to address air shower malfunctions?
Addressing air shower malfunctions involves identifying the issue through thorough inspection, repairing or replacing faulty components, and retesting the system to ensure it functions correctly. Regular maintenance can help prevent future malfunctions.
4. What training is required for air shower operation?
Training for air shower operation includes familiarizing personnel with the system’s controls, proper entry and exit procedures, and routine maintenance checks. Staff should also be trained on emergency protocols in case of system failure.
5. How to integrate air showers into a production line?
Integrating air showers into a production line requires strategic placement to minimize workflow disruption, ensuring sufficient space for installation, and coordinating with production schedules. Consulting with experts can facilitate a smooth integration process.
6. What are the guidelines for air shower use in research facilities?
Guidelines for air shower use in research facilities include:
Regularly cleaning and maintaining the unit
Ensuring proper usage by trained personnel
Conducting routine performance tests
These practices help maintain a contamination-free environment for sensitive research activities.
7. How to ensure air shower compliance with health regulations?
Ensuring air shower compliance with health regulations involves adhering to industry standards, conducting regular inspections, and maintaining detailed records of maintenance and performance tests. Consulting with regulatory experts can help navigate specific requirements.
8. How to ensure consistent performance of air showers?
To ensure consistent performance of air showers, conduct regular maintenance, including cleaning and replacing filters, calibrating airflow settings, and inspecting mechanical components. Staff training on proper usage also plays a crucial role.
9. What are the latest advancements in air shower technology?
Recent advancements in air shower technology include improved HEPA filter efficiency, automated control systems for better monitoring and maintenance, and energy-efficient blowers. These innovations enhance performance and reduce operational costs.
10. How to handle air shower emergency situations?
Handling air shower emergency situations involves:
Training staff on emergency protocols
Providing clear instructions for manual override
Regularly testing emergency systems
These measures ensure quick and effective responses to any issues.
11. What are the installation requirements for air showers?
Installation requirements for air showers include adequate space for the unit, proper electrical connections, and ensuring that the location supports the weight and structural dimensions of the air shower. Consulting with installation experts ensures compliance with these requirements.
12. What are the safety features of an automatic assembly line air shower?
Safety features of an automatic assembly line air shower include interlocking doors to prevent contamination, emergency stop buttons, and automated cycle controls to ensure consistent decontamination processes. These features enhance operational safety and efficiency.
13. How to maintain the blower in an air shower?
Maintaining the blower in an air shower involves regular inspection for wear and tear, cleaning or replacing filters, and ensuring proper lubrication of moving parts. Scheduled maintenance checks can prevent blower failures and extend its lifespan.
14. How to integrate air showers into a warehouse setting?
Integrating air showers into a warehouse setting involves assessing the flow of goods and personnel, ensuring sufficient space for installation, and coordinating with warehouse operations to minimize disruption. Custom solutions may be required for optimal integration.
15. How to ensure air shower system compatibility?
Ensuring air shower system compatibility involves:
Assessing existing infrastructure
Consulting with manufacturers for customized solutions
Verifying electrical and spatial requirements
These steps ensure the new system integrates seamlessly with current operations.
16. How to manage air shower noise levels?
Managing air shower noise levels can be achieved by using sound-dampening materials, regular maintenance of blower units, and ensuring proper installation to minimize vibration. Noise reduction measures enhance the working environment for personnel.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unit -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unit -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unit -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 unit -
Air Filter
US$3-50 USD/Unit
Min. Order:1 unit -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 unit -
Pass Box
US$200-500 USD/Unit
Min. Order:1 unit -
FFU
US$135-350 USD/Unit
Min. Order:1 unit -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 unit -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 unit -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 unit -
Clean room ceiling
US$
Min. Order:1 unit