MENU
X

GDC™ Auto Sensor Air Shower - 1200(W)x2000(D)x2200(H)

Reference Price:US$2300.00-3800.00

Short Description:

GDC™ automatic assembly line goods shower room: also known as air shower room, it is personnel or goods into the clean area by the fan through the air shower nozzles sprayed through the high efficiency filtration of clean air blowing off the surface of the person or object adsorption of dust is a very strong generality of the local purification equipment.

  • External dimension: 1200*2000*2200
  • inner dimension: 800*900*1960
  • material: 201 stainless steel
  • Number of applicants: 3-4
  • thicknesses: 1.2mm
  • Number of fans: 2 sets*0.55Kw/set
  • Number of nozzles: 12
  • door closer: “Dorma“
  • electronic lock: “Luxgen” electric locks
  • weights: 350kg
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Product Certification: ASHRAE 110 ASTM E84 CAN/CSA C22.2 CE NFPA 45
  • customs code: 43534654

Select your requirements for air shower materials

  • Quantity:

Choose your Plate Thickness Requirements

  • Quantity:

Select your local supply voltage

  • Quantity:

Summary

Air Shower

GDC™ Auto Sensor Air Shower - 1200(W)x2000(D)x2200(H)

Choose your upgrade options

Air Shower Detail

The Auto Sensor Air Shower is a high-efficiency cleanroom equipment designed to remove particulate matter and contaminants from personnel and materials before they enter clean environments. Equipped with advanced sensor technology, the Auto Sensor Air Shower automatically detects the presence of personnel or objects, initiating and ceasing the air shower process to ensure efficient and energy-saving operation.

Deiiang air shower playbill.jpg

Features

  • Automatic Sensing: Infrared/ultrasonic sensors for automatic operation

  • High-Efficiency Filtration: HEPA/ULPA filters capture 99.97%+ particles ≥ 0.3 microns

  • Programmable Control: Touchscreen/PLC for setting parameters

  • Omnidirectional Nozzles: Multi-angle, high-velocity air jets

  • Emergency Stop: Immediate cessation for safety

  • Stainless Steel: Durable, corrosion-resistant construction

  • Interlocking Doors: Prevents cross-contamination

  • Low-Noise Design: Quiet operation for user comfort

Industry Applications

  • Electronics Manufacturing: Semiconductor and microelectronics

  • Pharmaceuticals: Drug manufacturing and packaging

  • Food Processing: High hygiene standards in production

  • Biotechnology: Labs and production facilities

  • Aerospace: Manufacturing and assembly

  • Automotive: Painting and assembly processes

Stainless steel air shower room10.jpg

Stainless steel air shower room6.jpg

Stainless steel air shower room9.jpg


Air shower room details2.jpg

Air shower room details1.jpg

Air Shower Parameter

Indicator Model 1`Purifier STD 2`Purifier STD 3`Purifier STD 4`Purifier STD 5`Purifier STD
Material Selection


1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel

SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot)

Number of applicants

1 person

2 persons (affordable)

3.4 persons (2 persons standard)

3.4 persons (3 persons standard) 6.8 persons (4 persons standard)
Number of nozzles 12 (bilateral) 18 (bilateral) 24 (bilateral) 36 (bilateral) 48 (bilateral)
Air velocity 24-30m/s 24-30m/s 24-30m/s 24-30m/s 24-30m/s
Electronic lock brand "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks
Efficient size 600x600x120mm 820x600x120mm

600x600x120mm

600x600x120mm

600x600x120mm
Overall Dimension 1400W*1000D*2100H 1400W*1500D*2100H 1400W*2000D*2100H 1400W*3000D*2100H 1400W*4000D*2100H
Internal dimensions 800w*900D*1960H 800w*1400D*1960H 800w*1900D*1960H 800w*2900D*1960H 800w*3900D*1960H
power supply

380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground).

The air shower room can be customized with 220V and 110V power supply according to customers' requirements.)

Lighting LED recessed light 1pc LED recessed light 2pc LED recessed light 2pc LED recessed light 3pc LED recessed light 4pc
Number of fans

2 sets "0.55Kw/set

2 sets~0.75KW/set

4 units "0.55Kw/unit

6 sets "0.55KW/set

8 units*0.55Kw/unit
Power of the whole machine

1.1Kw

1.5Kw

2.2Kw

3.3Kw 4.4Kw
Stall capacity (kg) 350kg

500kg

650kg

950kg 1250kg
Indicator Model 1`Purifier STD 2`Purifier STD 3`Purifier STD
Material Selection


1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel

SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot)

Number of applicants

1 person

2 persons (affordable)

3.4 persons (2 persons standard)

Number of nozzles 12 (bilateral) 18 (bilateral) 24 (bilateral)
Air velocity 24-30m/s 24-30m/s 24-30m/s
Electronic lock brand "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks
Efficient size 600x600x120mm 820x600x120mm

600x600x120mm

Overall Dimension 1400W*1000D*2100H 1400W*1500D*2100H 1400W*2000D*2100H
Internal dimensions 800w*900D*1960H 800w*1400D*1960H 800w*1900D*1960H
power supply

380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground).

The air shower room can be customized with 220V and 110V power supply according to customers' requirements.)

Lighting LED recessed light 1pc LED recessed light 2pc LED recessed light 2pc
Number of fans

2 sets "0.55Kw/set

2 sets~0.75KW/set

4 units "0.55Kw/unit

Power of the whole machine

1.1Kw

1.5Kw

2.2Kw

Stall capacity (kg) 350kg

500kg

650kg

Indicator Model 3`Purifier STD 4`Purifier STD 5`Purifier STD
Material Selection

1.2mm high quality cold rolled disease plate baking paint, outside steel plate baking paint inside stainless steel

SUS304 stainless steel inside and outside (double doors and floor are SUS304 stainless steel pot)

Number of applicants

3.4 persons (2 persons standard)

3.4 persons (3 persons standard) 6.8 persons (4 persons standard)
Number of nozzles 24 (bilateral) 36 (bilateral) 48 (bilateral)
Air velocity 24-30m/s 24-30m/s 24-30m/s
Electronic lock brand "Luxgen" electric locks "Luxgen" electric locks "Luxgen" electric locks
Efficient size

600x600x120mm

600x600x120mm

600x600x120mm
Overall Dimension 1400W*2000D*2100H 1400W*3000D*2100H 1400W*4000D*2100H
Internal dimensions 800w*1900D*1960H 800w*2900D*1960H 800w*3900D*1960H
power supply

380V, 50Hz (three-phase five-wire power supply, three fires, one connection and one ground).

The air shower room can be customized with 220V and 110V power supply according to customers' requirements.)

Lighting LED recessed light 2pc LED recessed light 3pc LED recessed light 4pc
Number of fans

4 units "0.55Kw/unit

6 sets "0.55KW/set

8 units*0.55Kw/unit
Power of the whole machine

2.2Kw

3.3Kw 4.4Kw
Stall capacity (kg)

650kg

950kg 1250kg

Air Shower Structure

Stainless steel air shower room configuration structure

Air shower room structure diagram.jpg

  • Top cover

  • Door closer

  • Suction cup lock

  • Lighting

  • Control panel

  • Emergency switch

  • Stainless steel door

  • Stainless steel nozzle

  • High efficiency filter

  • Box

  • Primary filter

  • Specialized fan

  • Stainless steel chassis

Air Shower Usage

Air Shower Room Operation Steps

How to use the air shower

Prepare:

  • Ensure you are properly attired in cleanroom garments.

  • Verify that the air shower is operational.

Enter:

  • Step into the air shower room and close the door behind you.

  • Stand in the designated area and remain still.

Activate:

  • Wait for the air shower cycle to start automatically.

  • The air jets will begin, removing contaminants.

Exit:

  • After the cycle completes, open the exit door.


FAQ

1. What are the installation steps for air showers?

The installation steps for air showers include selecting an appropriate location, ensuring adequate space for the unit, and connecting to the power supply. Additionally, integrating with existing HVAC systems and performing initial testing is crucial.


2. How to ensure air shower longevity?

Ensuring air shower longevity involves regular maintenance, timely replacement of filters, and periodic inspections of mechanical and electrical components. Proper training for users can also extend the lifespan of the unit.


3. What are the common issues with air shower systems?

Common issues with air shower systems include malfunctioning blowers, clogged filters, and faulty sensors. Regular maintenance and prompt repairs are essential to prevent these problems.


4. How to ensure air shower filter efficiency?

Ensuring air shower filter efficiency requires regular inspection and timely replacement of filters. Monitoring air pressure levels and maintaining a clean environment around the air shower can also help maintain filter performance.


5. What are the safety features of an automatic assembly line air shower?

Safety features of an automatic assembly line air shower include interlocking doors to prevent simultaneous opening, emergency stop buttons, and sensors to detect obstructions. Additionally, alarms and indicators provide real-time status updates.


6. How to integrate air showers into a production line?

Integrating air showers into a production line involves careful planning of the workflow, ensuring alignment with existing processes, and coordinating with other equipment. Consulting with a professional can help optimize the integration.


7. What is an automatic assembly line air shower?

An automatic assembly line air shower is a specialized equipment designed to remove contaminants from personnel and materials automatically as they move through a production line. It uses sensors and automated controls for efficient operation.


8. What are HEPA filters in air showers?

HEPA filters in air showers are high-efficiency particulate air filters that capture 99.97% of particles as small as 0.3 microns. These filters are crucial for maintaining cleanroom standards and preventing contamination.


9. What are the best practices for air shower installation?

Best practices for air shower installation include:

  • Conducting a site assessment

  • Ensuring proper alignment with HVAC systems

  • Providing adequate space for maintenance

Proper planning and adherence to manufacturer guidelines are essential for a successful installation.


10. How to choose between different air shower models?

Choosing between different air shower models involves evaluating factors such as the size of the cleanroom, the number of users, and specific industry requirements. Consulting with manufacturers or experts can help make an informed decision.


11. How to troubleshoot air shower blower issues?

Troubleshooting air shower blower issues involves checking for electrical connections, ensuring there are no blockages in the air ducts, and inspecting the blower motor for wear and tear. Professional service may be required for complex problems.


12. How to select the correct air shower model?

Selecting the correct air shower model depends on the specific needs of the facility, including the volume of traffic, space constraints, and contamination control requirements. Consulting with a supplier can provide tailored solutions.


13. How to troubleshoot common air shower problems?

Troubleshooting common air shower problems includes:

  • Checking the power supply

  • Inspecting filters for clogs

  • Verifying sensor functionality

Regular maintenance and prompt attention to issues can prevent downtime.


14. What are the potential hazards of using air showers?

Potential hazards of using air showers include electrical hazards, mechanical failures, and improper use leading to contamination. Regular maintenance and user training are crucial to mitigate these risks.


15. What are the power requirements for an air shower?

The power requirements for an air shower vary based on its size and features, typically ranging from 220V to 380V. Ensuring an adequate power supply is essential for proper operation.


16. How to manage air shower noise levels?

Managing air shower noise levels can be achieved by using quieter blowers, installing soundproofing materials, and performing regular maintenance to prevent mechanical noise. Proper installation also plays a role in noise reduction.


17. How to handle air shower replacement parts?

Handling air shower replacement parts involves keeping an inventory of critical components, sourcing parts from reliable suppliers, and performing timely replacements to ensure continuous operation.


18. What are the benefits of air showers in cleanroom environments?

Air showers provide numerous benefits in cleanroom environments, including reducing particulate contamination, enhancing product quality, and ensuring compliance with industry standards. They are essential for maintaining stringent cleanliness levels.

Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.