What is the filter coverage of ISO 5?

  • Author:Jason Peng

  • Cleanroom Engineering Technology Manager of Deiiang Company.

    Product R&D Manager of GDC Inc. Cleanroom Equipment Manufacturing Company.

    Executive Director of Guangdong Cleanroom Industry Association of China.

    Engaged in R&D of related products for 15 years, with rich relevant technical experience

  • 2024-12-05  |  Visits:


What is the Filter Coverage of ISO 5?

ISO 5 Cleanrooms are critical environments defined by stringent cleanliness standards. According to the ISO 14644-1 classification system, ISO 5 Cleanrooms must maintain a maximum allowable particle count of 3,520 particles per cubic meter for particles ≥0.5 microns. Achieving this level of cleanliness requires effective air filtration systems, specifically HEPA (High-Efficiency Particulate Air) filters or ULPA (Ultra-Low Penetration Air) filters. 

ISO 5 Cleanroom Standards for 14644-1 Certification (FS209E Class 100)

Importance of Filter Coverage:

Filter coverage refers to the arrangement and efficiency of Air Filters within A CleanRoom. In ISO 5 environments, proper filter coverage is vital to minimize contamination. Typically, a cleanroom's air supply system will utilize a combination of HEPA or ULPA filters mounted in ceiling grids or integrated into air handling units. The filters must cover the entire airflow area to ensure that all the air entering the cleanroom is adequately filtered. 

HEPA and ULPA Filters:

HEPA filters are designed to capture at least 99.97% of particles that are 0.3 microns in size, while ULPA filters can capture up to 99.999% of 0.1-micron particles. The choice between HEPA and ULPA filters often depends on the specific application within the cleanroom. For ISO 5 cleanrooms, HEPA filters are commonly used due to their effectiveness and cost efficiency. 

ULPA vs. HEPA Filters | Air Filter Selection Guide | Air Innovations

Airflow Patterns:

The layout and airflow patterns in an ISO 5 cleanroom are designed to optimize filter coverage. Typically, unidirectional airflow is employed, where air flows in a single direction, creating a laminar flow that effectively sweeps away particles and contaminants. This design ensures that air passes through the filters before it reaches the working area. 

In conclusion, filter coverage in ISO 5 cleanrooms is a critical factor in maintaining air quality and cleanliness. Effective use of HEPA and ULPA filters, combined with careful design of airflow patterns, ensures that contaminants are minimized, thereby upholding the integrity of sensitive processes.


ISO5 Overview

Cleanroom - What is a Cleanroom - Skov Industri

ISO5 cleanrooms, defined by iso 14644-1, allow a maximum of 3,520 particles per cubic meter for particles ≥0.5 microns. This cleanliness level is critical for industries like pharmaceuticals and Semiconductors. Stringent controls on airflow, temperature, humidity, and personnel gowning, along with effective HEPA or ULPA filters, are essential.




ISO 5 Cleanroom Air Changes

What are ISO 5 Cleanrooms? A Beginner's Guide

In an ISO 5 cleanroom, maintaining the required level of cleanliness involves ensuring adequate air changes per hour (ACH). The recommended ACH for ISO 5 cleanrooms ranges from 240 to 600 air changes per hour, depending on the specific application and design of the facility. This high rate of air exchange helps to dilute and remove airborne contaminants, maintaining the stringent cleanliness standards required for critical processes.


ISO 5 Cleanroom Gowning Requirements

What are the Requirements for an ISO 4 Cleanroom?

1. Clean room design Calculation

Designing A Clean Room, particularly one that meets ISO 5 standards, involves several critical calculations to ensure compliance with cleanliness requirements. These calculations typically revolve around airflow, filter coverage, and room dimensions. Below are key considerations in clean room design.

2. Airflow Requirements

The airflow velocity is essential for maintaining the required cleanliness levels. For ISO 5 cleanrooms, the airflow should typically be around 0.45 meters per second (90 feet per minute) in the work area. This velocity helps achieve proper air exchange and promote laminar flow, which is crucial for minimizing contamination. The total airflow required can be calculated using the formula:

微信截图_20241205162028.png

Where CFM is cubic feet per minute and ACH is air changes per hour. For example, if a cleanroom has a volume of 1,000 cubic feet and requires 300 ACH, the required airflow would be:

微信截图_20241205162037.png

3. Filter Coverage

Filter coverage is another crucial aspect of clean room design. In an ISO 5 cleanroom, HEPA or ULPA filters must cover the entire ceiling area, ensuring that all air entering the room is effectively filtered. The number of filters needed can be determined by calculating the total ceiling area and the coverage area of each filter. Typically, a cleanroom will have a grid layout of filters that ensures uniform airflow across the space.

4. Room Dimensions

The dimensions of the cleanroom must also be considered. Ideally, cleanrooms should have a height of at least 10 to 12 feet to accommodate the air handling units and allow adequate air circulation. The design should facilitate unidirectional airflow, meaning the layout should prevent air from short-circuiting and ensure that all air passes through the HEPA or ULPA filters before reaching the work area.

Behaviour rules in a cleanroom


Clean Room HVAC Design Calculations

1. Cooling Load Calculation: The cooling load must be calculated to ensure that the cleanroom maintains a stable temperature. The formula is:

微信截图_20241205162316.png

Where total heat gain includes factors such as lighting, equipment, and personnel.

2. Dehumidification Requirements: Cleanrooms must maintain specific humidity levels, typically around 30-60% relative humidity for ISO 5. The dehumidification load can be calculated using psychrometric charts or specific formulas that account for the air entering the cleanroom.

3. Filter Selection: The HVAC system should use HEPA or ULPA filters to remove airborne particles. The selection of filters should consider the airflow rate and pressure drop across the filters to ensure energy efficiency and effective filtration.


What are the Guidelines for ISO 5?

ISO 5 Cleanrooms – ISO 5 Cleanroom Requirements - Pristine Clean Bags®

Particle Count Monitoring

One of the primary guidelines for maintaining ISO 5 cleanliness is the continuous monitoring of airborne particles. Facilities must employ real-time particle counters to ensure that the particle count does not exceed the established limits. Regular audits and validations should be conducted to confirm compliance with ISO 14644-1 standards.

Airflow Management

Proper airflow management is critical in an ISO 5 cleanroom. The design should support unidirectional airflow to minimize turbulence and particle accumulation. Airflow patterns should be tested and validated regularly to ensure that the cleanroom maintains its integrity during operation.

Mastering Cleanroom Contamination Control: Strategies for Ensuring Personnel  Cleanliness in Clean Rooms - Cleanroom Suit | Cleanroom clothing |Cleanroom  coverall

Personnel Training and Gowning Procedures

Personnel must be adequately trained in cleanroom protocols, including proper gowning procedures. Training sessions should cover the importance of minimizing contamination and the correct methods for entering and exiting the cleanroom. Regular refresher courses should be conducted to ensure that all personnel adhere to the guidelines.

Maintenance and Cleaning Protocols

Regular maintenance of the cleanroom facilities and equipment is essential for compliance. Cleaning protocols should be established, including the use of appropriate cleaning agents that do not leave residues. Surfaces should be cleaned and disinfected regularly, and the HVAC systems should be maintained to ensure optimal performance.