ISO 14644-2:2015(EN)
ISO 14644-2 is part of the ISO 14644 series of standards that provides guidelines for monitoring and maintaining the performance of cleanrooms and controlled environments. This standard specifically addresses the requirements for monitoring cleanroom air cleanliness and environmental conditions to ensure that they meet the classification specified in ISO 14644-1. ISO 14644-2 outlines the procedures for ongoing monitoring of particle concentrations, as well as other environmental parameters like temperature, humidity, and pressure. It also specifies the frequency and methods for testing and inspecting cleanrooms to ensure that they continue to meet their designated cleanliness levels throughout their operational life. The standard emphasizes the importance of regular validation, calibration, and data analysis to detect any deviations from cleanliness standards and to maintain the necessary conditions for critical processes in industries such as pharmaceuticals, biotechnology, and electronics manufacturing.

Your Reliable Manufacturer of ISO 14644-2:2015(EN)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISO's adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 209, Cleanrooms and associated controlled environments.
This second edition cancels and replaces the first edition (ISO 14644-2:2000), which has been technically revised throughout.
ISO 14644 consists of the following parts, under the general title Cleanrooms and associated controlled environments:
Part 1: Classification of air cleanliness by particle concentration
Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration
Part 3: Test methods
Part 4: Design, construction and start-up
Part 5: Operations
Part 7: Separative devices (clean air hoods, gloveboxes, isolators and mini-environments)
Part 8: Classification of air cleanliness by chemical concentration (ACC)
Part 9: Classification of surface cleanliness by particle concentration
Part 10: Classification of surface cleanliness by chemical concentration
Attention is also drawn to ISO 14698, Cleanrooms and associated controlled environments — Bio-contamination control:
Part 1: General principles and methods
Part 2: Evaluation and interpretation of bio-contamination data
Introduction
This revision of ISO 14644-2 emphasizes the need to consider a monitoring strategy in addition to the initial or periodic execution of the classification of a cleanroom or clean zone in accordance with ISO 14644-1:2015, 5.1. The monitoring activity provides a continuing flow of data over time, thereby providing a more detailed view of the performance of the installation.
Potential benefits gained from monitoring are
faster response to adverse events and conditions,
ability to develop trends from data over time,
integration of data from multiple instruments,
enhanced knowledge of installation and process, which allows for more effective risk assessment, and
improved control of operational costs and product losses.
ISO 14644-2 specifies the requirements of a monitoring plan, based on risk assessment of the intended use. The data obtained provide evidence of cleanroom or clean zone performance related to air cleanliness by particle concentration.
In some circumstances, relevant regulatory agencies may impose supplementary policies, requirements or restrictions. In such situations, appropriate adaptations of the monitoring procedures may be required. After a monitoring plan is initially established and implemented, it may be necessary to revise the plan when significant changes are made to the installation or process requirements. It is also prudent to conduct periodic reviews of a monitoring plan based on data obtained and experience in use.
- Video
- Workshop
- Data sheet
- Certificate
Related Products
Help to Find Your Cleanroom Related Products
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unit -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unit -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unit -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 unit -
Air Filter
US$3-50 USD/Unit
Min. Order:1 unit -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:100 square -
Pass Box
US$200-500 USD/Unit
Min. Order:1 unit -
FFU
US$135-350 USD/Unit
Min. Order:1 unit
ISO 14644-2:2015(EN) Video Introduction
FAQ
Q: What is ISO 14644-2 guidelines?
A: ISO 14644-2 provides guidelines for the monitoring and control of cleanrooms and controlled environments. It outlines the requirements for ongoing cleanliness verification, including the frequency and methods for testing airborne particle concentrations, airflow, temperature, and humidity in cleanrooms. The standard ensures that cleanrooms maintain their classification over time, and it provides procedures for sampling, data collection, and interpretation to ensure continued compliance with the cleanliness levels required for specific operations.
Q: What is the current version of ISO 14644?
A: The current version of ISO 14644 is ISO 14644-1:2015 and ISO 14644-2:2015, both of which are the latest revisions of the standard. ISO 14644-1:2015 defines the classification of cleanrooms based on airborne particle concentration, while ISO 14644-2:2015 provides guidelines for cleanroom monitoring and performance verification. Both revisions include updated guidelines and procedures to reflect modern practices in cleanroom design, operation, and maintenance.
Q: Is EN ISO 14644-1?
A: Yes, EN ISO 14644-1 is the European version of ISO 14644-1. The "EN" prefix indicates that it is a European Standard, which harmonizes ISO standards across Europe. EN ISO 14644-1 specifies the classification of cleanrooms based on the concentration of airborne particles, and it is recognized and adopted by member countries of the European Union for cleanroom standards and compliance in regulated industries like pharmaceuticals, electronics, and aerospace.
Q: What is NF EN ISO 14644-1:2015?
A: NF EN ISO 14644-1:2015 is the French version of ISO 14644-1:2015, which is a harmonized international standard for cleanroom classification. "NF" stands for "Norme Française," indicating that this is the French national standard for cleanrooms, and "EN" means it aligns with European standards. The 2015 revision of this standard defines the classification of cleanrooms based on airborne particle count, establishing limits for various particle sizes to ensure air cleanliness and product integrity in controlled environments.
Q: What is ISO 14644-2 guidelines?
A: ISO 14644-2 provides guidelines for the ongoing monitoring and verification of cleanroom performance. This standard focuses on the procedures and requirements for measuring airborne particle levels, airflow, temperature, humidity, and other environmental factors to ensure that cleanrooms maintain the required cleanliness levels over time. It includes recommendations on how often to take measurements and how to interpret the data to maintain compliance with ISO 14644-1 classifications.
Q: What is ISO 14644-1:2015?
A: ISO 14644-1:2015 is the updated version of the standard that defines the classification of cleanrooms based on airborne particulate contamination. It sets out the criteria for classifying cleanrooms from Class 1 (the cleanest) to Class 9 (the least clean), specifying allowable particle concentrations for different particle sizes, such as 0.5 microns, per cubic meter of air. This version of the standard emphasizes modern techniques for particle counting and more detailed sampling procedures to ensure accurate classification.
Q: What is the latest version of ISO 14644?
A: The latest version of ISO 14644 includes ISO 14644-1:2015 and ISO 14644-2:2015. These revisions provide updated criteria for the classification of cleanrooms based on airborne particle concentration (ISO 14644-1) and guidelines for monitoring and maintaining the cleanliness levels of cleanrooms (ISO 14644-2). These versions reflect advancements in cleanroom technology, testing methods, and international best practices, ensuring cleaner, safer environments in industries that require controlled contamination.
Q: What is the ISO standard for cleanroom validation?
A: The ISO standard for cleanroom validation is ISO 14644-2, which provides guidelines for the ongoing monitoring and validation of cleanrooms to ensure they maintain the required levels of cleanliness. Validation involves verifying that cleanroom conditions, such as particle concentrations, airflow, temperature, and humidity, consistently meet the cleanliness class specified in ISO 14644-1. This process includes periodic testing and adjustments to ensure compliance with the appropriate standards and regulations.