MENU
X

75mm Thickness MGO Cleanroom Panel,Steelplate:0.326mm

Reference Price:US$from $20/㎡

Min. Order:100 square meter

Short Description:

The 75mm thickness MGO cleanroom panel is designed for high-performance applications in controlled environments. Constructed from magnesium oxide (MGO), t

  • width: 1200mm
  • Thicknesses: 75mm
  • Density: 80kg/m
  • Lenth: Customizable

Cleanroom

75mm Thickness MGO Cleanroom Panel,Steelplate:0.326mm

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

75mm Thickness MGO Cleanroom Panel,Steelplate:0.326mm

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Detail

The 75mm thickness MGO cleanroom panel is designed for high-performance applications in controlled environments. Constructed from magnesium oxide (MGO), these panels offer excellent moisture resistance, fire resistance, and durability, making them ideal for cleanrooms in industries such as pharmaceuticals, biotechnology, and electronics. Their thickness provides enhanced insulation and structural integrity, ensuring a stable environment while facilitating easy cleaning and maintenance.

Their thick design enhances insulation properties, contributing to energy efficiency while maintaining stringent cleanliness standards.

cleanroom MGO panel Product Poster.jpg

Advantage

  • Fire protection: 60 minutesHighDensity,

  • High Temperature ResistanceStrong Bearing capacit



Parameter

Product nameCleanroom MGO  Panel
Thicknessupper layer0.4mm-0.8mm
core material50mm-150mm
bottom layer0.4mm-0.8mm
Effective Widthstandard950mm, 1150mm
othercan be customized
Lengthcan be customized,less than 12m
Density24kg/㎡
ColorRal Standard
Temp tolerance1500℃
Hydrophobic rate≥97.5%
Fire resistance levelA (>70 minutes)
Surface profileflat,corrugated,big rib, small wave
Compression bearing22Mpa(GB/T7019-1997)
The shrinking rate when heated1.0%(GA160-1997)
The rate of deformation when pick up the moisture0.26%(GA160-1997)
Product nameCleanroom MGO  Panel
Thicknessupper layer0.4mm-0.8mm
core material50mm-150mm
bottom layer0.4mm-0.8mm
Effective Widthstandard950mm, 1150mm
othercan be customized
Lengthcan be customized,less than 12m
Density24kg/㎡
ColorRal Standard
Temp tolerance1500℃
Hydrophobic rate≥97.5%
Fire resistance levelA (>70 minutes)
Surface profileflat,corrugated,big rib, small wave
Compression bearing22Mpa(GB/T7019-1997)
The shrinking rate when heated1.0%(GA160-1997)
The rate of deformation when pick up the moisture0.26%(GA160-1997)

Features

  • Sound insulation ≥44db(GBJ121-88)

  • Superior heat insulation performance, waterproof and moisture-proof

  • Beautiful appearance.

  • High density, anti-bending, can be sawed, nailed and glued.

  • Environmentally friendly

  • Anti-freezing, anti-cracking.

  • Weatherproof

  • Light weight, very easy to insulate and disassemble

  • Safe, 100% free of asbestos, formaldehyde and benzene

  • Lifespan >20 years

Applications

  • Indoor and outdoor boards for purifying factory building, combined house and indoor partition with high level requirement in fire

  • proofing and thermal insulation. E.g.Interior decoration of civil buildings

  • for medicine, electronics, biology research, foodstuff, beverage etc.

FAQ

1. Can MGO panels be used in high-humidity environments?

Yes, MGO panels are suitable for high-humidity environments due to their moisture-resistant properties. They do not absorb water, which prevents mold growth and structural degradation. This makes them an excellent choice for applications like laboratories and pharmaceutical manufacturing where humidity control is critical.


2. What are the safety standards for cleanroom wall panels?

Cleanroom wall panels must comply with several safety standards to ensure they provide a safe environment. Key standards include:

  • ASTM E84 for flame spread and smoke development

  • ISO 14644 for cleanroom classification

  • NFPA guidelines for fire safety

These standards help in ensuring that the panels do not release harmful particles or gases into the cleanroom environment.


3. How do you design a cleanroom with MGO panels?

Designing a cleanroom with MGO panels involves several key considerations. First, determine the cleanliness class required based on the specific application and industry standards. Next, plan the layout to include necessary features such as airlocks, gowning areas, and utility access. Selecting the right size and thickness of MGO panels is crucial for insulation and structural stability.

Additionally, ensure proper sealing at joints and seams to maintain air pressure differentials and prevent contamination. Finally, integrate HVAC systems that work efficiently with the MGO panels to maintain temperature and humidity control.


4. Can MGO panels be used in food processing facilities?

MGO panels are indeed suitable for food processing facilities, as they are non-toxic, easy to clean, and resistant to moisture. Their durability and resistance to mold growth make them an ideal choice for maintaining hygiene standards in food production environments.


5. How do you troubleshoot issues with cleanroom panels?

Troubleshooting cleanroom panels involves a systematic approach. Start by inspecting the panels for any visible damage, such as cracks or discoloration. Check for proper sealing at joints and seams to prevent contamination. Additionally, monitor environmental controls to ensure they are functioning correctly.


6. How do cleanroom panels contribute to indoor air quality?

Cleanroom panels significantly enhance indoor air quality by minimizing particles, VOCs, and microbial contamination. Their smooth surfaces facilitate easy cleaning and maintenance, which helps maintain a sterile environment. Moreover, the materials used in MGO panels do not off-gas harmful substances, further improving air quality.


7. Are cleanroom wall panels resistant to chemicals?

Yes, cleanroom wall panels, particularly MGO panels, are resistant to a variety of chemicals, which makes them suitable for use in laboratories and pharmaceutical settings. Their non-porous surface prevents chemical absorption and degradation, ensuring longevity and maintaining cleanliness.


8. Can cleanroom panels be retrofitted?

Cleanroom panels can be retrofitted to accommodate changes in facility layout or to enhance performance. This process typically involves removing existing panels and installing new ones or modifying current ones to improve functionality while adhering to cleanliness standards. Consulting with experts is advisable to ensure compatibility and compliance.


9. Are cleanroom wall panels customizable?

Yes, cleanroom wall panels are highly customizable to meet specific requirements. They can be tailored in terms of size, thickness, color, and surface finish. Customization allows facilities to optimize layout and aesthetics while ensuring compliance with cleanliness and safety standards.


10. How do you clean MGO cleanroom panels?

Cleaning MGO cleanroom panels typically involves using non-abrasive cleaners and a soft cloth or mop. Start by removing loose dust and debris, then apply an appropriate cleaning solution to sanitize the surface. Avoid harsh chemicals that may damage the panel’s integrity.


11. What is the R-value of cleanroom wall panels?

The R-value of cleanroom wall panels varies based on materials and thickness but is essential for thermal insulation. MGO panels generally offer a good R-value, contributing to energy efficiency in climate-controlled environments. Consulting product specifications can provide precise R-values for specific panel types.


12. How do cleanroom panels handle vibration?

Cleanroom panels are engineered to minimize vibration and enhance stability. Their construction allows for dampening of vibrations, which is critical in sensitive environments like laboratories and manufacturing facilities. Proper installation and support structures further enhance their ability to withstand vibrations.


13. What are the fire codes for cleanroom wall panels?

Fire codes for cleanroom wall panels are dictated by local regulations and industry standards### 13. What are the fire codes for cleanroom wall panels?

Fire codes for cleanroom wall panels are dictated by local regulations and industry standards such as the National Fire Protection Association (NFPA) and Underwriters Laboratories (UL). These codes specify requirements for fire resistance, flame spread ratings, and smoke development indexes. Compliance ensures that cleanroom panels can withstand potential fire hazards, protecting both the facility and personnel.


14. How do MGO panels compare to rock wool panels?

MGO panels and rock wool panels serve different purposes and have distinct advantages. MGO panels are known for their moisture resistance and structural durability, while rock wool panels offer excellent sound insulation and fire resistance. Key comparison points include:

  • Moisture Resistance: MGO panels are superior in humid environments.

  • Insulation: Rock wool panels provide better acoustic insulation.

  • Fire Resistance: Both types are fire-resistant, but rock wool has a higher fire rating.

Ultimately, the choice between MGO and rock wool panels depends on the specific needs of the cleanroom application.


15. How often should cleanroom panels be inspected?

Cleanroom panels should be inspected regularly to ensure they maintain their integrity and performance. A recommended schedule is at least once a month, with more frequent inspections during high-traffic periods or when environmental conditions change. Inspections should focus on checking for physical damage, cleanliness, and proper sealing to prevent contamination.


16. What troubleshooting tips exist for cleanroom panels?

When troubleshooting cleanroom panels, consider the following tips:

  • Inspect for visible signs of damage or wear.

  • Check seals and joints for gaps that could allow contamination.

  • Evaluate environmental controls for proper operation.

Document any issues and corrective actions taken to ensure compliance and maintain a clean environment.


17. How do you handle seams in cleanroom wall panels?

Handling seams in cleanroom wall panels is crucial for maintaining cleanliness and integrity. Seams should be sealed with appropriate sealants that are compatible with the panel materials. Regular inspection and maintenance of seams are necessary to prevent dust and contaminants from accumulating. Using specialized seam treatments can also enhance durability and ease of cleaning.


18. What is the difference between modular and traditional cleanroom panels?

The primary difference between modular and traditional cleanroom panels lies in their construction and installation. Modular panels are prefabricated and designed for easy assembly and disassembly, allowing for flexibility in cleanroom design. In contrast, traditional panels are often custom-built on-site and may require more time and resources for installation. Modular systems also allow for easier upgrades and retrofitting, making them a popular choice in dynamic environments.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.