11.3''11.3'x11.5' W-bank Combined medium filter,F6
Reference Price:US$from $10
Min. Order:1 unitCleanroom
11.3''11.3'x11.5' W-bank Combined medium filter,F6
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
11.3''11.3'x11.5' W-bank Combined medium filter,F6
Validation
Installation & Validation
Find Similar Products
-
23'x23'x11.5' W-bank combined medium-ef
US$From $60
Min. Order:1 unit -
23'x23'x11.5' W-bank Combined medium fi
US$From $60
Min. Order:1 unit -
2850m³/h W-bank Combined medium filter,F
US$From $60
Min. Order:1 unit -
2850m³/h W-bank Combined medium filter,F
US$From $60
Min. Order:1 unit -
11.3''11.3'x11.5' W-bank Combined mediu
US$From $60
Min. Order:1 unit -
11.3''11.3'x11.5' W-bank Combined mediu
US$From $60
Min. Order:1 unit
Product Description
The 11.3''x11.3''x11.5' W-bank combined medium filter (F6) offers efficient filtration for HVAC systems, capturing medium-sized particles like dust and allergens. Its W-shaped multi-pocket design maximizes surface area for enhanced performance, ensuring cleaner air in commercial and industrial environments. Deiiang™ provides a durable solution for maintaining optimal air quality.
Design Features

01High Filtration Efficiency
High Filtration Efficiency
Captures fine dust and particulates, improving air quality.

02Enhanced Airflow Capacity
Enhanced Airflow Capacity
Designed to handle high airflow rates without compromising performance.

03Durable Construction
Durable Construction
Built for long-lasting use in demanding environments.

04F9 Classification
F9 Classification
Meets high-efficiency standards, ensuring effective filtration for various applications.
photo
Material composition
Product dimensions parameters
Material Parameters
Frame Material | Aluminum profile/aluminum folded frame/galvanized frame/stainless steel frame |
Filter Media Material | Polypropylene pp meltblown fiber or microfiberglass filter paper |
Frame Sealant | PU two-component polyurethane AB adhesive |
Filter Bag Type | Ultrasonic bag/self-sewn bag |
Protective Mesh | Sprayed diamond mesh |
Separator | EVA hot melt adhesive |
Sealant Strip | EVA Neoprene |
Filtration efficiency | F6:65%@0.5 m, F7:85%@0. 5m F8:90%@0.5 um, F9:95%@0.5um |
Maximum temperature | 70°C |
Maximum humidity | 80% |
Frame Material | Aluminum profile/aluminum folded frame/galvanized frame/stainless steel frame |
Filter Media Material | Polypropylene pp meltblown fiber or microfiberglass filter paper |
Frame Sealant | PU two-component polyurethane AB adhesive |
Filter Bag Type | Ultrasonic bag/self-sewn bag |
Protective Mesh | Sprayed diamond mesh |
Separator | EVA hot melt adhesive |
Sealant Strip | EVA Neoprene |
Filtration efficiency | F6:65%@0.5 m, F7:85%@0. 5m F8:90%@0.5 um, F9:95%@0.5um |
Maximum temperature | 70°C |
Maximum humidity | 80% |
Technical Parameters
SIZE(WXHXD)(mm) | Number of spacers | Rated airflow(m3/h) | Filter area(m²) | Dust capacity(g) | Initial resistance(Pa) | Ultimate resistance(Pa) | Filter efficiency |
287*287*292 | 2 | 900 | 4.63 | ≈280 | ≤60 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400-450 | F9 | |||||
592*592*292 | 3 | 2850 | 15.03 | ≈900 | ≤560 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400 -450 | F9 |
SIZE(WXHXD)(mm) | Number of spacers | Rated airflow(m3/h) | Filter area(m²) | Dust capacity(g) | Initial resistance(Pa) | Ultimate resistance(Pa) | Filter efficiency |
287*287*292 | 2 | 900 | 4.63 | ≈280 | ≤60 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400-450 | F9 | |||||
592*592*292 | 3 | 2850 | 15.03 | ≈900 | ≤560 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400 -450 | F9 |
FAQ
1. What are the maintenance requirements for W-bank filters?
W-bank filters require periodic inspection and maintenance to ensure optimal performance. Regular checks for visible damage, clogging, or excessive pressure drop are essential. The filter media should be replaced once it is saturated or when airflow resistance becomes too high. Deiiang™ recommends following the manufacturer's guidelines for cleaning and replacing W-bank filters to maintain efficiency and prolong their lifespan.
2. What is the most effective filtration media in a W-bank filter?
The most effective filtration media in a W-bank filter is a combination of synthetic fibers and activated carbon. Synthetic fibers efficiently capture particulate matter, while activated carbon adsorbs gases and odors. This combination ensures that W-bank filters provide both high particulate filtration and air purification, making them suitable for a variety of environments. Deiiang™ designs W-bank filters with premium materials to enhance filtration performance.
3. What are the benefits of using a V-bank filter?
The benefits of using a V-bank filter include: - High filtration efficiency with a large surface area. - Improved dust-holding capacity for longer-lasting performance. - Reduced airflow resistance compared to flat-panel filters. These features make V-bank filters ideal for environments where air quality and high airflow are critical. Deiiang™ V-bank filters are designed to meet these needs while ensuring reliable and efficient filtration.
4. What is the lifespan of a V-bank combined medium filter?
The lifespan of a V-bank combined medium filter varies depending on factors such as air quality, filter usage, and maintenance. Typically, a well-maintained V-bank filter can last between 6 to 12 months. However, the filter may need to be replaced earlier in environments with higher levels of contaminants. Deiiang™ recommends regular monitoring and replacement based on pressure drop readings and visual inspection.
5. What is the filtration capacity of a V-bank activated carbon filter?
A V-bank activated carbon filter is capable of capturing both particulates and gaseous contaminants such as volatile organic compounds (VOCs), odors, and chemical fumes. The filtration capacity depends on the filter's size and the concentration of pollutants in the air. Deiiang™ V-bank filters with activated carbon are highly effective in environments with chemical emissions or strong odors, ensuring cleaner and healthier air.
6. Can V-bank filters effectively remove diesel fumes?
Yes, V-bank filters with activated carbon are effective at removing diesel fumes. The activated carbon adsorbs the harmful gases and chemicals found in diesel exhaust, improving air quality in environments exposed to diesel emissions. Deiiang™ V-bank filters offer high filtration efficiency for industrial, commercial, and residential settings, ensuring cleaner air in spaces where diesel fumes are prevalent.
7. What is the difference between W-bank and V-bank filters?
The primary difference between W-bank and V-bank filters lies in their design and filtration efficiency. W-bank filters feature a multi-pocket, W-shaped design that maximizes surface area for capturing medium-sized particulates, making them ideal for environments with consistent airflow needs. V-bank filters, on the other hand, use a V-shaped pleated design that enhances dust removal capacity and is suited for high-flow applications. Deiiang™ offers both filter types for diverse filtration requirements.
8. Are there any specific installation guidelines for V-bank filters?
Yes, proper installation of V-bank filters is essential for optimal performance. The filters should be installed in the correct airflow direction and sealed properly to prevent air bypass. It's important to check that the filter fits securely in its housing and that there are no gaps around the edges. Deiiang™ provides detailed installation instructions for V-bank filters to ensure they are installed correctly for maximum efficiency.
9. What is the expected performance of a W-bank combined medium filter?
The expected performance of a W-bank combined medium filter is high filtration efficiency with minimal airflow resistance. It effectively captures medium-sized particulates, such as dust, pollen, and smoke, while maintaining a low pressure drop. Deiiang™ W-bank filters are designed to provide long-lasting performance, ensuring clean air in commercial, industrial, and residential applications.
10. Are W-bank filters suitable for clean rooms?
Yes, W-bank filters are suitable for clean rooms, particularly those with moderate filtration requirements. These filters can capture airborne contaminants such as dust, bacteria, and allergens, helping to maintain a sterile environment. Deiiang™ W-bank filters are designed to meet the strict air quality standards required in clean rooms, providing reliable and efficient filtration.
11. How effective is the F9 rating for a V-bank filter?
The F9 rating for a V-bank filter indicates a high level of filtration efficiency, capable of capturing up to 90% of airborne particles in the 1-3 micron range. This makes the F9-rated V-bank filter suitable for environments requiring superior air quality, such as commercial and industrial HVAC systems. Deiiang™ V-bank filters with an F9 rating provide excellent performance in removing fine particulates.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unit -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unit -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unit -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 unit -
Air Filter
US$3-50 USD/Unit
Min. Order:1 unit -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 unit -
Pass Box
US$200-500 USD/Unit
Min. Order:1 unit -
FFU
US$135-350 USD/Unit
Min. Order:1 unit -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 unit -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 unit -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 unit -
Clean room ceiling
US$
Min. Order:1 unit