11.3''11.3'x11.5' W-bank Combined medium filter,F8
Reference Price:US$from $10
Min. Order:1 unitCleanroom
11.3''11.3'x11.5' W-bank Combined medium filter,F8
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
11.3''11.3'x11.5' W-bank Combined medium filter,F8
Validation
Installation & Validation
Find Similar Products
-
23'x23'x11.5' W-bank combined medium-ef
US$From $60
Min. Order:1 unit -
23'x23'x11.5' W-bank Combined medium fi
US$From $60
Min. Order:1 unit -
2850m³/h W-bank Combined medium filter,F
US$From $60
Min. Order:1 unit -
2850m³/h W-bank Combined medium filter,F
US$From $60
Min. Order:1 unit -
11.3''11.3'x11.5' W-bank Combined mediu
US$From $60
Min. Order:1 unit -
11.3''11.3'x11.5' W-bank Combined mediu
US$From $60
Min. Order:1 unit
Product Description
The 11.3''x11.3''x11.5' W-bank combined medium filter is engineered for efficient air filtration in various systems. Its W-shaped multi-pocket design maximizes surface area, allowing for better capture of medium-sized particulates and pollutants. This filter is ideal for commercial and industrial applications, providing reliable performance and enhanced air quality. Deiiang™ ensures that this filter meets rigorous standards for both efficiency and durability.
Design Features

01High Filtration Efficiency
High Filtration Efficiency
Captures fine dust and particulates, improving air quality.

02Enhanced Airflow Capacity
Enhanced Airflow Capacity
Designed to handle high airflow rates without compromising performance.

03Durable Construction
Durable Construction
Built for long-lasting use in demanding environments.

04F9 Classification
F9 Classification
Meets high-efficiency standards, ensuring effective filtration for various applications.
photo
Material composition
Product dimensions parameters
Material Parameters
Frame Material | Aluminum profile/aluminum folded frame/galvanized frame/stainless steel frame |
Filter Media Material | Polypropylene pp meltblown fiber or microfiberglass filter paper |
Frame Sealant | PU two-component polyurethane AB adhesive |
Filter Bag Type | Ultrasonic bag/self-sewn bag |
Protective Mesh | Sprayed diamond mesh |
Separator | EVA hot melt adhesive |
Sealant Strip | EVA Neoprene |
Filtration efficiency |
F6:65%@0.5 m, F7:85%@0. 5m F8:90%@0.5 um, F9:95%@0.5um |
Maximum temperature | 70°C |
Maximum humidity | 80% |
Frame Material | Aluminum profile/aluminum folded frame/galvanized frame/stainless steel frame |
Filter Media Material | Polypropylene pp meltblown fiber or microfiberglass filter paper |
Frame Sealant | PU two-component polyurethane AB adhesive |
Filter Bag Type | Ultrasonic bag/self-sewn bag |
Protective Mesh | Sprayed diamond mesh |
Separator | EVA hot melt adhesive |
Sealant Strip | EVA Neoprene |
Filtration efficiency |
F6:65%@0.5 m, F7:85%@0. 5m F8:90%@0.5 um, F9:95%@0.5um |
Maximum temperature | 70°C |
Maximum humidity | 80% |
Technical Parameters
SIZE(WXHXD)(mm) | Number of spacers | Rated airflow(m3/h) | Filter area(m²) | Dust capacity(g) | Initial resistance(Pa) | Ultimate resistance(Pa) | Filter efficiency |
287*287*292 | 2 | 900 | 4.63 | ≈280 | ≤60 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400-450 | F9 | |||||
592*592*292 | 3 | 2850 | 15.03 | ≈900 | ≤560 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400 -450 | F9 |
SIZE(WXHXD)(mm) | Number of spacers | Rated airflow(m3/h) | Filter area(m²) | Dust capacity(g) | Initial resistance(Pa) | Ultimate resistance(Pa) | Filter efficiency |
287*287*292 | 2 | 900 | 4.63 | ≈280 | ≤60 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400-450 | F9 | |||||
592*592*292 | 3 | 2850 | 15.03 | ≈900 | ≤560 | 250-300 | F6 |
≤80 | 300-400 | F7 | |||||
≤100 | 300-400 | F8 | |||||
≤120 | 400 -450 | F9 |
FAQ
1. How does the pleat design of a W-bank filter improve performance?
The pleat design of a W-bank filter improves performance by increasing the surface area available for filtration. This design allows the filter to capture a higher volume of airborne particles while maintaining efficient airflow. The pleated structure reduces pressure drop, ensuring that the filter can operate effectively in systems with varying airflow demands. Deiiang™’s W-bank filters are engineered to maximize filtration efficiency without compromising system performance.
2. What types of air systems use V-bank filters?
V-bank filters are commonly used in a wide range of air systems, including HVAC systems, cleanrooms, industrial ventilation systems, and air handling units. Their multi-pocket design is ideal for environments that require high-efficiency filtration, such as pharmaceutical labs, data centers, and manufacturing facilities. Deiiang®️’s V-bank filters are tailored for diverse applications where air quality standards must be maintained.
3. How effective is the F9 rating for a V-bank filter?
The F9 rating indicates that a V-bank filter is highly effective in removing medium-sized particulates and airborne contaminants. With an F9 rating, these filters are capable of capturing over 90% of particles in the 1-3 microns range, making them highly efficient for environments where air quality is crucial. Deiiang™ filters with this rating are commonly used in commercial and industrial HVAC systems, ensuring superior filtration and clean air.
4. What are the key features of W-bank combined medium filters?
The key features of W-bank combined medium filters include their unique multi-pocket, W-shaped design that maximizes surface area for efficient filtration. These filters capture a wide range of medium-sized particulates, such as dust, pollen, and smoke, improving indoor air quality. Additionally, W-bank filters are known for their durability and long-lasting performance, offering reliable filtration even in demanding environments.
5. Can V-bank filters help with VOC removal?
Yes, V-bank filters equipped with activated carbon media are effective for removing volatile organic compounds (VOCs) from the air. The activated carbon adsorbs harmful gases and odors, providing cleaner air in environments exposed to chemical pollutants. Deiiang™ offers V-bank filters designed specifically for VOC removal, ensuring both particulate and gaseous contaminants are effectively captured.
6. Are there any specific installation guidelines for V-bank filters?
Yes, V-bank filters should be installed according to the manufacturer's guidelines to ensure optimal performance. It is important to install the filter in the correct direction of airflow and ensure a secure fit to prevent air bypass. Proper sealing around the filter edges is also crucial to maintain system efficiency. Deiiang™ provides detailed installation instructions to ensure V-bank filters are correctly placed in HVAC and other air handling systems.
7. Can V-bank filters remove chemical fumes?
Yes, V-bank filters with activated carbon can effectively remove chemical fumes from the air. The activated carbon in these filters adsorbs gaseous pollutants, providing cleaner and healthier air in environments where chemical fumes are present. Deiiang®️ offers V-bank filters with enhanced capabilities for removing various types of chemical contaminants, ensuring air quality is maintained.
8. What makes W-bank filters different from traditional filters?
W-bank filters are different from traditional filters due to their advanced multi-pocket, W-shaped design. This design increases the surface area available for filtration, allowing the filter to capture more particulates without restricting airflow. In contrast, traditional filters typically use flat media, which can clog more quickly and may not capture as many contaminants. Deiiang™’s W-bank filters provide superior filtration efficiency, especially in demanding environments.
9. Can V-bank filters be used to remove industrial fumes?
Yes, V-bank filters can be used to remove industrial fumes, especially when equipped with specialized media like activated carbon. These filters are designed to capture a wide range of airborne contaminants, including fine particulate matter and gases commonly found in industrial settings. Deiiang™ V-bank filters are highly effective in environments exposed to industrial fumes, offering reliable filtration for improved air quality.
10. Is the V-bank filter effective for dust removal?
Yes, the V-bank filter is highly effective for dust removal due to its large surface area and multi-pocket design. This allows the filter to capture both fine and coarse dust particles, making it ideal for environments with high levels of dust, such as construction sites and manufacturing facilities. Deiiang™ V-bank filters are engineered to provide superior dust removal performance while maintaining efficient airflow.
11. How can I check if my V-bank filter needs replacing?
You can check if your V-bank filter needs replacing by inspecting its pressure drop across the filter. If the pressure drop exceeds the recommended level or if the filter appears visibly clogged with dust or debris, it’s time for a replacement. Additionally, regular monitoring of airflow and air quality can help identify when a filter is no longer performing at its best. Deiiang™ recommends following the manufacturer’s guidelines for replacement intervals to ensure optimal performance.
12. Can V-bank filters effectively remove diesel fumes?
Yes, V-bank filters can effectively remove diesel fumes, particularly when equipped with activated carbon or other media designed to capture gaseous pollutants. These filters are capable of trapping both particulate matter and harmful chemical vapors from diesel exhaust, improving air quality in environments exposed to diesel emissions. Deiiang™ V-bank filters offer enhanced filtration for environments where diesel fumes are a concern.
13. How do W-bank filters compare with HEPA filters?
W-bank filters and HEPA filters differ in their design and filtration efficiency. While HEPA filters are designed to capture very fine particulates with a minimum efficiency of 99.97%, W-bank filters are optimized for medium-sized particulates, offering a balance between high efficiency and lower airflow resistance. Deiiang™ W-bank filters are typically more suitable for environments where large volumes of air need to be filtered with a focus on medium particulates, while HEPA filters are ideal for highly sensitive environments requiring maximum filtration.
14. What is the difference between W-bank and V-bank filters?
The main difference between W-bank and V-bank filters lies in their design and filtration approach. W-bank filters use a W-shaped, multi-pocket design to maximize surface area and are ideal for capturing medium-sized particulates. V-bank filters, on the other hand, utilize a pleated V-shaped design that enhances dust capture efficiency and is particularly effective for high-flow environments. Both filters offer high efficiency but are optimized for different applications. Deiiang™ offers both types to meet specific filtration needs.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unit -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unit -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unit -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 unit -
Air Filter
US$3-50 USD/Unit
Min. Order:1 unit -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 unit -
Pass Box
US$200-500 USD/Unit
Min. Order:1 unit -
FFU
US$135-350 USD/Unit
Min. Order:1 unit -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 unit -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 unit -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 unit -
Clean room ceiling
US$
Min. Order:1 unit