A Desktop Clean Bench is a compact, portable workstation designed to create a localized, contamination-free environment for various sensitive laboratory tasks. It uses efficient filtration and laminar airflow to ensure a sterile workspace.
Type: Horizontal or Vertical Laminar Flow
Filter: HEPA (99.99% efficiency at 0.3 microns) or ULPA (99.999% efficiency at 0.12 microns)
Airflow Velocity: 0.45 m/s (90 fpm)
Dimensions: Typically 24" x 18" x 24" (W x D x H)
Material: Stainless steel or powder-coated steel
Lighting: Integrated LED
Noise Level: < 60 dB
Power Supply: 110-240V AC, 50/60 Hz
Weight: Approximately 30 kg (66 lbs)
Min. Order:1 Set
Catalog:Desktop Vertical Flow Clean Workbench
Min. Order:1 Set
Catalog:Desktop Vertical Flow Clean Workbench
Min. Order:1 Set
Catalog:Desktop Horizontal Flow Clean Workbench
Min. Order:1 Set
Catalog:Desktop Horizontal Flow Clean Workbench
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unitAir Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unitDownflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unitClean bench
US$600-2000 USD/Unit
Min. Order:1 unitAir Filter
US$3-50 USD/Unit
Min. Order:1 unitCleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:100 squareDeiiang is a trusted manufacturer specializing in high-quality Desktop Clean Benches, designed to provide a contamination-free environment for sensitive laboratory and industrial applications. Our products feature advanced HEPA or ULPA filtration systems, ensuring optimal air purity and protection for your critical processes.
With a commitment to innovation and excellence, Deiiang offers durable, user-friendly clean benches tailored to meet the stringent demands of various industries, including pharmaceuticals, biotechnology, electronics, and research laboratories. Trust Deiiang for reliable performance and superior quality in maintaining your sterile workspace.
A desktop clean bench is a compact workstation designed to provide a localized, contamination-free environment for sensitive laboratory processes. It utilizes laminar airflow and high-efficiency particulate air (HEPA) filters to ensure a sterile workspace.
A desktop laminar flow hood works by drawing air through a HEPA filter, which removes contaminants. The filtered air is then directed in a horizontal or vertical laminar flow across the work surface, creating a sterile environment.
Desktop clean benches are widely used in various industries, including pharmaceuticals, biotechnology, electronics, and research laboratories. They are essential for any application requiring a contamination-free environment.
Pharmaceuticals
Biotechnology
Electronics
Research Laboratories
The main difference between a vertical and horizontal laminar flow hood is the direction of the airflow. In a vertical laminar flow hood, air flows downward from the top, while in a horizontal laminar flow hood, air flows horizontally from the back towards the front.
HEPA filters in a desktop clean bench should generally be replaced every 12 to 18 months, depending on the usage and environment. Regular monitoring of filter performance can help determine the optimal replacement schedule.
Yes, a desktop clean bench can be used for microbiology applications. It provides a sterile environment to prevent contamination of microbial cultures and sensitive biological samples.
Prevents contamination
Suitable for microbial cultures
Ensures sample integrity
Using a desktop laminar flow hood offers several benefits, including a contamination-free work environment, protection of sensitive samples, and improved experimental accuracy. It also enhances safety by containing potentially hazardous substances.
Maintaining a desktop clean bench involves regularly cleaning the work surface with appropriate disinfectants, replacing HEPA filters as needed, and ensuring the airflow system is functioning correctly. Routine checks and maintenance protocols help sustain optimal performance.
Standard dimensions of a desktop clean bench typically include a width of 24 inches, a depth of 18 inches, and a height of 24 inches. These compact dimensions make it suitable for placement on most laboratory desks and workbenches.
The cost of a desktop laminar flow hood can vary widely depending on the brand, features, and specifications. Generally, prices range from $1,000 to $5,000.
The airflow velocity in a desktop clean bench is typically around 0.45 meters per second (90 feet per minute). This consistent airflow ensures the removal of airborne contaminants from the work area.
A desktop clean bench can provide protection against viruses to some extent by maintaining a sterile environment through HEPA filtration. However, it is not designed to fully contain viral pathogens as a biosafety cabinet would.
Provides sterile environment
Utilizes HEPA filtration
Not a substitute for biosafety cabinets
Desktop clean benches are commonly constructed from stainless steel or powder-coated steel. These materials are chosen for their durability, ease of cleaning, and resistance to corrosion.
Installing a desktop laminar flow hood involves placing it on a stable, level surface, ensuring proper electrical connections, and verifying that the airflow system is functioning correctly. Follow the manufacturer's installation instructions for optimal setup.
The power requirement for a desktop clean bench typically ranges from 110 to 240 volts AC, 50/60 Hz. This allows for compatibility with standard electrical outlets in most laboratories.
Cleaning a desktop laminar flow hood involves wiping down the work surface and interior with a suitable disinfectant. Regular cleaning should be done to prevent contamination and maintain a sterile environment.
The noise level of a desktop clean bench is typically less than 60 decibels. This low noise operation ensures a comfortable working environment without significant auditory distraction.
HEPA filters in a desktop laminar flow hood are highly effective, providing 99.99% efficiency at capturing particles as small as 0.3 microns. This ensures a sterile workspace by removing airborne contaminants.
Yes, a desktop clean bench is suitable for electronics assembly. It provides a clean environment free of dust and particles that could damage sensitive electronic components.
The lifespan of a desktop clean bench can vary based on usage and maintenance. Generally, with proper care, a desktop clean bench can last for several years, often ranging from 5 to 10 years.
Lifespan: 5 to 10 years
Depends on usage and maintenance
Proper care extends longevity