DC FFU,Fan Filter Unit,22.6' x 46.3',Air volume:1000m³/h

Reference Price:US$from $75

Short Description:

The DC Fan Filter Unit (FFU) is a high-efficiency air filtration solution designed for cleanroom applications and controlled environments. Measuring 22.6" x 46.3", this unit delivers an impressive air volume of 1000 m³/h,

  • Style: DC Fan FFU
  • Dimension: 575x1175x220
  • Filter Dimension: 570x1170x69
  • Air Volume: 1000m³/h
  • Noise: 52~62dB(A)
  • Air Pressure: 200PA
  • Power: 200W
  • Weight: 35Kg
  • Material: Galvanized
  • Supply Power: AC 1N 110,220V/50,60Hz

Cleanroom

DC FFU,Fan Filter Unit,22.6' x 46.3',Air volume:1000m³/h

Choose your installation & validation options below

  • Quantity:

Choose your Cleanroom frame structure material

  • Quantity:

Choose your Cleanroom Wall enclosure materials

  • Quantity:

Choose your Temperature requirements

  • Quantity:

Choose your humidity requirements

  • Quantity:

Choose your Explosion-proof requirements

  • Quantity:

Summary

Cleanroom

DC FFU,Fan Filter Unit,22.6' x 46.3',Air volume:1000m³/h

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Features

The DC Fan Filter Unit (FFU) is a high-efficiency air filtration solution designed for cleanroom applications and controlled environments. Measuring 22.6" x 46.3", this unit delivers an impressive air volume of 1000 m³/h, effectively eliminating airborne contaminants and maintaining superior air quality. Featuring a DC motor, it operates quietly while consuming less energy compared to traditional AC systems. Its compact design facilitates easy installation, making it ideal for laboratories, hospitals, and other critical settings where clean air is essential.

ffu product poster.jpg

Cleanroom FFU Product Details:

ffu fan.jpg

01
Explosion-proof design

Prevents ignition of flammable gases or dusts

500airvolume-ffu5.jpg

02
Air filter

High efficiency HEPA/ULPA filter

Stable airflow distribution

DC fan FFU.jpg

03
Installation and Maintenance

Easy to install and maintain

Compact design for flexible integration

FFU.jpg

04
Compliance with international standards

Compliant with ISO cleanroom standards

Advanced fan technology for improved air circulation

Work Principle

  • Structural components: fan, filter, housing

  • Air flow: The fan draws in ambient air, which passes through the filter.

  • Filtration process: the filter removes particles (e.g. dust, microorganisms) from the air.

  • Clean air release: Filtered clean air is released from the top or bottom.

Work Principle

Models

Product NameDC FFU
Product ModelDC-FFU-A01DC-FFU-A02DC-FFU-A03DC-FFU-A04
Dimension(mm)575x575x220575x1175x220875x1175x2751175x1175x295
Filter Dimension(mm)570x570x69570x1170x69870x1170x691170x1170x69
Air Volume500m³/h1000m³/h1500m³/h2000m³/h
Noise52~55dB(A)52~55dB(A)52~55dB(A)52~55dB(A)
Air Pressure200PA200PA260PA290PA
Power170W170W200W240W
Weight28Kg35Kg47Kg55Kg
MaterialGalvanized/powder coated/SUS 304 plate
Supply PowerAC 1N 110, 220V/50,60Hz
Control System3 stage regulation, group reguation
Filter Efficiency99.95%MPPS above H13-U16@EN1822
Pre FilterG3/G4 Filter, nylon filter
Work Statuspower Indicator, work indicator, Error indicator
Connection Type3 Pin Aviation Male Female socket, terminat blocks
Overload ProtectionOverload protect of motor and controller
Monitor Contact Communication Methodport of reserve and Erro
Product NameDC FFU
Product ModelDC-FFU-A01DC-FFU-A02DC-FFU-A03DC-FFU-A04
Dimension(mm)575x575x220575x1175x220875x1175x2751175x1175x295
Filter Dimension(mm)570x570x69570x1170x69870x1170x691170x1170x69
Air Volume500m³/h1000m³/h1500m³/h2000m³/h
Noise52~55dB(A)52~55dB(A)52~55dB(A)52~55dB(A)
Air Pressure200PA200PA260PA290PA
Power170W170W200W240W
Weight28Kg35Kg47Kg55Kg
MaterialGalvanized/powder coated/SUS 304 plate
Supply PowerAC 1N 110, 220V/50,60Hz
Control System3 stage regulation, group reguation
Filter Efficiency99.95%MPPS above H13-U16@EN1822
Pre FilterG3/G4 Filter, nylon filter
Work Statuspower Indicator, work indicator, Error indicator
Connection Type3 Pin Aviation Male Female socket, terminat blocks
Overload ProtectionOverload protect of motor and controller
Monitor Contact Communication Methodport of reserve and Erro

Accessories

  • HEPA Filter

  • ULPA Filter

  • Adjustable speed fan

  • Fixed speed fan

  • Manual control panel

  • Digital remote control system

  • Monitoring sensors (pressure)

FAQ

1. Can DC FFUs be connected to a building management system?

Yes, DC Fan Filter Units (FFUs) can be connected to a building management system (BMS). This integration allows for real-time monitoring, control, and optimization of air quality within the facility. By connecting the FFUs to a BMS, facility managers can enhance energy efficiency and ensure compliance with cleanliness standards.


2. How to ensure proper alignment during DC FFU installation?

To ensure proper alignment during the installation of a DC FFU, follow these steps:

  • Check the mounting surface for levelness.

  • Use a laser level or measuring tape for precise alignment.

  • Secure the unit firmly to avoid any vibrations.

Careful attention to detail during installation will help maintain optimal performance and prevent operational issues.


3. What is the impact of humidity on DC FFUs?

Humidity can significantly impact the performance of DC Fan Filter Units. High humidity levels may lead to condensation, which can affect the efficiency of the filters and potentially damage the unit. On the other hand, extremely low humidity can cause static electricity buildup, negatively impacting filtration effectiveness. Therefore, maintaining appropriate humidity levels is crucial for optimal FFU operation.


4. Can DC FFUs be used in laboratories?

Yes, DC FFUs are widely used in laboratories. Their ability to provide a controlled airflow and maintain cleanroom standards makes them ideal for sensitive environments such as research labs, pharmaceutical manufacturing, and medical facilities. The low energy consumption and quiet operation further enhance their suitability for laboratory settings.


5. How to calculate the total static pressure for a DC Fan Filter Unit?

To calculate the total static pressure for a DC FFU, you need to consider the following factors:

  • Airflow rate (in m³/h)

  • Filter type and resistance (measured in Pa)

  • Ductwork design and length

The total static pressure can be calculated by summing the filter resistance and the duct losses, allowing for proper system design and efficiency.


6. How to test the airflow of a DC FFU?

Testing the airflow of a DC Fan Filter Unit can be accomplished using an anemometer. Place the anemometer at the FFU's air outlet and measure the velocity. Multiply the velocity by the cross-sectional area of the outlet to determine the airflow in cubic meters per hour (m³/h). Regular testing ensures that the unit is functioning within its specified parameters.


7. How do DC FFUs compare to traditional air purifiers?

DC FFUs are generally more efficient than traditional air purifiers. They are designed for high air exchange rates and are often used in professional settings such as cleanrooms and laboratories. In contrast, traditional air purifiers are typically intended for residential use and may not provide the same level of filtration or airflow. Additionally, DC FFUs offer lower energy consumption and quieter operation.


8. How to connect a DC FFU to a backup power source?

To connect a DC FFU to a backup power source, ensure that the unit's specifications match the backup system's output. Use appropriate wiring and connectors to link the FFU to the backup power supply, ensuring that the installation complies with local electrical codes. Testing the setup before a power outage is recommended to verify proper operation.


9. How to determine the size of a DC FFU for my space?

To determine the appropriate size of a DC FFU for your space, consider the following factors:

  • Room size and volume

  • Desired air change rate

  • Filter efficiency and type

Calculating the required airflow based on these factors will help you select the right FFU to maintain cleanliness standards in your environment.


10. What are the common applications for DC FFUs?

DC FFUs are commonly used in various applications, including:

  • Cleanrooms for pharmaceuticals

  • Biotechnology labs

  • Medical facilities and hospitals

Their ability to provide controlled air quality makes them suitable for any environment that requires stringent cleanliness standards.


11. What factors influence the performance of a DC Fan Filter Unit?

The performance of a DC Fan Filter Unit is influenced by several factors, including filter design, airflow rate, humidity levels, and the cleanliness of the environment. Regular maintenance and timely filter replacement are also crucial for maintaining optimal performance and ensuring thatthe unit operates effectively over time.


12. What are the environmental ratings for DC Fan Filter Units?

DC Fan Filter Units typically come with various environmental ratings that indicate their efficiency and suitability for different applications. Common ratings include:

  • HEPA (High-Efficiency Particulate Air) filters for particulate matter removal

  • Energy efficiency ratings (such as ENERGY STAR)

  • Operating temperature and humidity ranges

These ratings help users select the right FFU for their specific environmental needs and compliance requirements.


13. What power supply is needed for a DC Fan Filter Unit?

A DC Fan Filter Unit typically requires a low-voltage DC power supply, often ranging from 24V to 48V, depending on the model. It is important to ensure that the power supply matches the specifications of the FFU to ensure optimal performance and safety. Consulting the manufacturer's guidelines will provide the necessary information for selecting the correct power supply.


14. Can a DC FFU be converted to AC?

Generally, a DC Fan Filter Unit cannot be directly converted to AC due to differences in motor design and power requirements. However, it may be possible to use a DC to AC inverter to operate the unit on an AC power supply, though this approach is not typically recommended. It is advisable to consult with the manufacturer or a qualified technician for proper guidance if conversion is desired.


15. What is the role of the pre-filter in a DC Fan Filter Unit?

The pre-filter in a DC Fan Filter Unit serves a crucial role in extending the life of the primary HEPA or ULPA filter by capturing larger particles and debris. This initial filtration step helps maintain airflow efficiency and reduces the load on the main filter, ultimately enhancing the overall performance and longevity of the FFU. Regular maintenance of the pre-filter is essential to ensure optimal functioning of the unit.

Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.