DC FFU,Fan Filter Unit,22.6' x 46.3',Air volume:1000m³/h
Reference Price:US$from $75






Cleanroom
DC FFU,Fan Filter Unit,22.6' x 46.3',Air volume:1000m³/h
Choose your installation & validation options below
Quantity:
Choose your Cleanroom frame structure material
Quantity:
Choose your Cleanroom Wall enclosure materials
Quantity:
Choose your Temperature requirements
Quantity:
Choose your humidity requirements
Quantity:
Choose your Explosion-proof requirements
Quantity:
Summary
DC FFU,Fan Filter Unit,22.6' x 46.3',Air volume:1000m³/h
Validation
Installation & Validation
Features
The DC Fan Filter Unit (FFU) is a high-efficiency air filtration solution designed for cleanroom applications and controlled environments. Measuring 22.6" x 46.3", this unit delivers an impressive air volume of 1000 m³/h, effectively eliminating airborne contaminants and maintaining superior air quality. Featuring a DC motor, it operates quietly while consuming less energy compared to traditional AC systems. Its compact design facilitates easy installation, making it ideal for laboratories, hospitals, and other critical settings where clean air is essential.
Cleanroom FFU Product Details:

01Explosion-proof design
Prevents ignition of flammable gases or dusts

02Air filter
High efficiency HEPA/ULPA filter
Stable airflow distribution

03Installation and Maintenance
Easy to install and maintain
Compact design for flexible integration

04Compliance with international standards
Compliant with ISO cleanroom standards
Advanced fan technology for improved air circulation
Work Principle
Structural components: fan, filter, housing
Air flow: The fan draws in ambient air, which passes through the filter.
Filtration process: the filter removes particles (e.g. dust, microorganisms) from the air.
Clean air release: Filtered clean air is released from the top or bottom.
Models
Product Name | DC FFU | |||
Product Model | DC-FFU-A01 | DC-FFU-A02 | DC-FFU-A03 | DC-FFU-A04 |
Dimension(mm) | 575x575x220 | 575x1175x220 | 875x1175x275 | 1175x1175x295 |
Filter Dimension(mm) | 570x570x69 | 570x1170x69 | 870x1170x69 | 1170x1170x69 |
Air Volume | 500m³/h | 1000m³/h | 1500m³/h | 2000m³/h |
Noise | 52~55dB(A) | 52~55dB(A) | 52~55dB(A) | 52~55dB(A) |
Air Pressure | 200PA | 200PA | 260PA | 290PA |
Power | 170W | 170W | 200W | 240W |
Weight | 28Kg | 35Kg | 47Kg | 55Kg |
Material | Galvanized/powder coated/SUS 304 plate | |||
Supply Power | AC 1N 110, 220V/50,60Hz | |||
Control System | 3 stage regulation, group reguation | |||
Filter Efficiency | 99.95%MPPS above H13-U16@EN1822 | |||
Pre Filter | G3/G4 Filter, nylon filter | |||
Work Status | power Indicator, work indicator, Error indicator | |||
Connection Type | 3 Pin Aviation Male Female socket, terminat blocks | |||
Overload Protection | Overload protect of motor and controller | |||
Monitor Contact Communication Method | port of reserve and Erro |
Product Name | DC FFU | |||
Product Model | DC-FFU-A01 | DC-FFU-A02 | DC-FFU-A03 | DC-FFU-A04 |
Dimension(mm) | 575x575x220 | 575x1175x220 | 875x1175x275 | 1175x1175x295 |
Filter Dimension(mm) | 570x570x69 | 570x1170x69 | 870x1170x69 | 1170x1170x69 |
Air Volume | 500m³/h | 1000m³/h | 1500m³/h | 2000m³/h |
Noise | 52~55dB(A) | 52~55dB(A) | 52~55dB(A) | 52~55dB(A) |
Air Pressure | 200PA | 200PA | 260PA | 290PA |
Power | 170W | 170W | 200W | 240W |
Weight | 28Kg | 35Kg | 47Kg | 55Kg |
Material | Galvanized/powder coated/SUS 304 plate | |||
Supply Power | AC 1N 110, 220V/50,60Hz | |||
Control System | 3 stage regulation, group reguation | |||
Filter Efficiency | 99.95%MPPS above H13-U16@EN1822 | |||
Pre Filter | G3/G4 Filter, nylon filter | |||
Work Status | power Indicator, work indicator, Error indicator | |||
Connection Type | 3 Pin Aviation Male Female socket, terminat blocks | |||
Overload Protection | Overload protect of motor and controller | |||
Monitor Contact Communication Method | port of reserve and Erro |
Accessories
HEPA Filter
ULPA Filter
Adjustable speed fan
Fixed speed fan
Manual control panel
Digital remote control system
Monitoring sensors (pressure)
FAQ
1. Can DC FFUs be connected to a building management system?
Yes, DC Fan Filter Units (FFUs) can be connected to a building management system (BMS). This integration allows for real-time monitoring, control, and optimization of air quality within the facility. By connecting the FFUs to a BMS, facility managers can enhance energy efficiency and ensure compliance with cleanliness standards.
2. How to ensure proper alignment during DC FFU installation?
To ensure proper alignment during the installation of a DC FFU, follow these steps:
Check the mounting surface for levelness.
Use a laser level or measuring tape for precise alignment.
Secure the unit firmly to avoid any vibrations.
Careful attention to detail during installation will help maintain optimal performance and prevent operational issues.
3. What is the impact of humidity on DC FFUs?
Humidity can significantly impact the performance of DC Fan Filter Units. High humidity levels may lead to condensation, which can affect the efficiency of the filters and potentially damage the unit. On the other hand, extremely low humidity can cause static electricity buildup, negatively impacting filtration effectiveness. Therefore, maintaining appropriate humidity levels is crucial for optimal FFU operation.
4. Can DC FFUs be used in laboratories?
Yes, DC FFUs are widely used in laboratories. Their ability to provide a controlled airflow and maintain cleanroom standards makes them ideal for sensitive environments such as research labs, pharmaceutical manufacturing, and medical facilities. The low energy consumption and quiet operation further enhance their suitability for laboratory settings.
5. How to calculate the total static pressure for a DC Fan Filter Unit?
To calculate the total static pressure for a DC FFU, you need to consider the following factors:
Airflow rate (in m³/h)
Filter type and resistance (measured in Pa)
Ductwork design and length
The total static pressure can be calculated by summing the filter resistance and the duct losses, allowing for proper system design and efficiency.
6. How to test the airflow of a DC FFU?
Testing the airflow of a DC Fan Filter Unit can be accomplished using an anemometer. Place the anemometer at the FFU's air outlet and measure the velocity. Multiply the velocity by the cross-sectional area of the outlet to determine the airflow in cubic meters per hour (m³/h). Regular testing ensures that the unit is functioning within its specified parameters.
7. How do DC FFUs compare to traditional air purifiers?
DC FFUs are generally more efficient than traditional air purifiers. They are designed for high air exchange rates and are often used in professional settings such as cleanrooms and laboratories. In contrast, traditional air purifiers are typically intended for residential use and may not provide the same level of filtration or airflow. Additionally, DC FFUs offer lower energy consumption and quieter operation.
8. How to connect a DC FFU to a backup power source?
To connect a DC FFU to a backup power source, ensure that the unit's specifications match the backup system's output. Use appropriate wiring and connectors to link the FFU to the backup power supply, ensuring that the installation complies with local electrical codes. Testing the setup before a power outage is recommended to verify proper operation.
9. How to determine the size of a DC FFU for my space?
To determine the appropriate size of a DC FFU for your space, consider the following factors:
Room size and volume
Desired air change rate
Filter efficiency and type
Calculating the required airflow based on these factors will help you select the right FFU to maintain cleanliness standards in your environment.
10. What are the common applications for DC FFUs?
DC FFUs are commonly used in various applications, including:
Cleanrooms for pharmaceuticals
Biotechnology labs
Medical facilities and hospitals
Their ability to provide controlled air quality makes them suitable for any environment that requires stringent cleanliness standards.
11. What factors influence the performance of a DC Fan Filter Unit?
The performance of a DC Fan Filter Unit is influenced by several factors, including filter design, airflow rate, humidity levels, and the cleanliness of the environment. Regular maintenance and timely filter replacement are also crucial for maintaining optimal performance and ensuring thatthe unit operates effectively over time.
12. What are the environmental ratings for DC Fan Filter Units?
DC Fan Filter Units typically come with various environmental ratings that indicate their efficiency and suitability for different applications. Common ratings include:
HEPA (High-Efficiency Particulate Air) filters for particulate matter removal
Energy efficiency ratings (such as ENERGY STAR)
Operating temperature and humidity ranges
These ratings help users select the right FFU for their specific environmental needs and compliance requirements.
13. What power supply is needed for a DC Fan Filter Unit?
A DC Fan Filter Unit typically requires a low-voltage DC power supply, often ranging from 24V to 48V, depending on the model. It is important to ensure that the power supply matches the specifications of the FFU to ensure optimal performance and safety. Consulting the manufacturer's guidelines will provide the necessary information for selecting the correct power supply.
14. Can a DC FFU be converted to AC?
Generally, a DC Fan Filter Unit cannot be directly converted to AC due to differences in motor design and power requirements. However, it may be possible to use a DC to AC inverter to operate the unit on an AC power supply, though this approach is not typically recommended. It is advisable to consult with the manufacturer or a qualified technician for proper guidance if conversion is desired.
15. What is the role of the pre-filter in a DC Fan Filter Unit?
The pre-filter in a DC Fan Filter Unit serves a crucial role in extending the life of the primary HEPA or ULPA filter by capturing larger particles and debris. This initial filtration step helps maintain airflow efficiency and reduces the load on the main filter, ultimately enhancing the overall performance and longevity of the FFU. Regular maintenance of the pre-filter is essential to ensure optimal functioning of the unit.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set