600'280℃High Temperature Separated High Efficiency Filter,H13
Reference Price:US$
Min. Order:Cleanroom
600'280℃High Temperature Separated High Efficiency Filter,H13
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
600'280℃High Temperature Separated High Efficiency Filter,H13
Validation
Installation & Validation
Find Similar Products
-
2000'400℃High Temperature Separated High
US$from $60
Min. Order: -
1500'400℃High Temperature Separated High
US$from $60
Min. Order: -
1000'400℃High Temperature Separated High
US$from $60
Min. Order: -
600'400℃High Temperature Separated High
US$from $60
Min. Order: -
250'400℃High Temperature Separated High
US$from $60
Min. Order: -
500'400℃High Temperature Separated High
US$from $60
Min. Order:
Product Description
High temperature resistant high efficiency filter with partition is a kind of filtration equipment designed for high temperature environment, which can work stably for a long time in the environment of 250-350℃, and is widely used in pharmaceutical factories, food processing, electronic manufacturing, and many other industries that need air purification under high temperature conditions. These filters usually use ultra-fine glass fiber filter paper as the filter material, together with aluminum foil partition and stainless steel or other high-temperature-resistant materials for the outer frame, and use high-temperature-resistant sealant for sealing. The main features of high-temperature-resistant high-efficiency filters are their high filtration performance, low resistance and good adaptability to high-temperature environments.
Design Features
High efficiency filtration
The high-temperature-resistant high-efficiency filter adopts ultra-fine glass fiber filter paper or other high-temperature-resistant filter materials, and with special structural design, it realizes effective filtration of particles with a particle size of 0.3μm and above, with an efficiency of 99.97% or more, which meets the requirements of the efficiency level of H13 and even H14.
Large-capacity dust holding capacity
These filters are usually designed with a large filtration layer and a reasonable pleated structure, which makes them have a large dust holding capacity and can maintain stable filtration performance even under high temperature conditions.
Low resistance
The design of high-temperature-resistant high-efficiency filters takes into account the principle of low resistance. By optimizing the filter material and partition structure, the wind resistance is reduced to ensure smooth air flow, which is crucial for maintaining the normal operation of the system.
High Temperature Resistance
High-temperature resistant compartmentalized HEPA filters can be used for a long period of time in environments ranging from 250°C to 350°C, and some can even reach 280°C, which makes them ideal for air filtration needs in high-temperature environments.
Stable structure
The outer frame of the filter is mostly made of stainless steel or galvanized material, while the inner part is made of high-temperature-resistant materials such as aluminum foil sheets as partitions, which ensures the stability and durability of the structure, and also helps to protect the inner filter material from damage.
框材 | 铝型材框、铝板折框、镀锌框、不锈钢框 |
滤料 | 耐高温超细玻璃纤维滤纸 |
密封胶 | 红色耐高温硅胶 |
防护网 | 无或不锈钢方格网 |
分隔物 | 0 035mm厚铝箔 |
密封胶条 | 6mm厚红色硅胶条 |
过滤效率 | H13:99 97-99 99%@0 3um H14:99.995-99 999%@0.3um |
使用最高温度 | 280℃ |
使用最高湿度 | 80% |
photo
Material composition
Application Fields
High-temperature resistant high efficiency filter with partition is mainly used to filter particulate matter generated in high-temperature environment, such as dust, smoke, etc., to ensure that the air quality meets the high standard requirements. Especially in the ultra-clean oven, high-temperature drying room, UV curing oven, aging box and other equipment air filtration performance.
Preparation before use
Before using the high-temperature resistant partitioned high-efficiency filter, you need to ensure the suitability of the installation environment, including temperature, humidity and other factors. Inspect the filter before installation to make sure there are no damages or defects. Also, make sure that there are no obstacles around the filter that could interfere with the passage of airflow.
Installation and Maintenance
The correct installation method is the key to guaranteeing the performance of the filter. During installation, attention should be paid to sealing to avoid gaps that could lead to air leakage. Regular maintenance is also necessary, including cleaning or replacing the filter media to ensure the continued efficient operation of the filter.
Product dimensions parameters
Design Features
High-temperature high efficiency filter with partition is a kind of filtration equipment designed for high temperature environment, mainly used for filtering air suspended particles above 0.3 micron, widely used in chemical, food, pharmaceutical and other industries for high temperature air purification equipment and systems.
Material composition
The filter media of high-temperature-resistant high efficiency filter with partition is mainly made of high-temperature-resistant ultra-fine glass fiber filter paper, and aluminum foil plate is used as the separator, the outer frame is usually stainless steel or galvanized plate, and it is sealed with special high-temperature-resistant sealant to ensure the sealing and durability of the whole filter.
Technical Parameters
The technical parameters of high-temperature resistant high efficiency filter with partition include but are not limited to the external dimensions, rated air volume, filter area, dust capacity, initial resistance, final resistance and filtration efficiency, etc. Among them, the filtration efficiency usually reaches H13. Among them, the filtration efficiency usually reaches H13 or H14 rating, which means that under certain conditions, the filter can effectively filter out at least 99.97% or more of 0.3 micron particles.
规格尺寸 (WXHXD)(mm) | 额定风量 (m³/h) | 过滤面积 (m²) | 容尘量 (g) | 初阻力 (Pa) | 终阻力 (Pa) | 过滤效率 |
320*320*150 | 250 | 2.59 | ≈160 | ≤200 | 400-600 | H13 |
≤220 | 400-600 | H14 | ||||
484*484*150 | 600 | 6 | ≈360 | ≤200 | 400-600 | H13 |
≤220 | 400-600 | H14 | ||||
610*610*150 | 1000 | 9.59 | ≈580 | ≤200 | 400-600 | H13 |
≤220 | 400-600 | H14 | ||||
915*610*150 | 1500 | 14.38 | ≈860 | ≤200 | 400-600 | H13 |
≤220 | 400-600 | H14 |
FAQ
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order: -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order: -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order: -
Clean bench
US$600-2000 USD/Unit
Min. Order: -
Air Filter
US$3-50 USD/Unit
Min. Order: -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order: -
Pass Box
US$200-500 USD/Unit
Min. Order: -
FFU
US$135-350 USD/Unit
Min. Order: -
Fume Hood
US$700-1500 USD/Unit
Min. Order: -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order: -
Clean room floor
US$5-20 USD/Sq.
Min. Order: -
Clean room ceiling
US$
Min. Order: