9 ft Horizontal Laminar Flow Cabinet
Reference Price:US$From $1200





Cleanroom
9 ft Horizontal Laminar Flow Cabinet
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
9 ft Horizontal Laminar Flow Cabinet
Validation
Installation & Validation
Find Similar Products
-
12 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
9 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
8 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
7 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
6 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
5 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set
Product Briefing
A 9 ft Horizontal Laminar Flow Cabinet provides a clean, particle-free workspace by directing HEPA-filtered air horizontally across its 9-foot-wide surface. Ideal for applications requiring high sterility, this cabinet is commonly used in fields such as microbiology, pharmaceuticals, and electronics.Here’s a detailed overview of its features, functions, and benefits:
Applications
Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.
Pharmaceuticals: Used in the preparation and compounding of sterile medications.
Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.
Research: Provides a clean environment for various scientific experiments and procedures.
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Features
High-Quality Construction
| |
Quiet Operation
| |
ULPA Filter
| |
Energy-efficient
| |
GDC™ Antimicrobial Powder Coating
|
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
-
Stainless Steel Orifice Tabletop
-
ULPA Ultra GX Filter
-
UV Germicidal Lamps
-
De-static equipment
-
Support Stand with Caster Wheels
FAQ
1. What is the role of a pre-filter in a Horizontal Laminar Flow Cabinet?
A pre-filter in a Horizontal Laminar Flow Cabinet serves to remove larger particles from the incoming air before it reaches the HEPA filter. This helps to extend the lifespan of the HEPA filter by preventing it from getting clogged with debris and dust, ensuring consistent airflow and maintaining the cabinet's sterility.
2. How to set up a Horizontal Laminar Flow Cabinet in a laboratory?
To set up a Horizontal Laminar Flow Cabinet in a laboratory, first select a stable and level location away from high-traffic areas and other airflow disruptions. Ensure there is adequate space around the cabinet for maintenance access. Connect the cabinet to an appropriate power source and verify electrical requirements. Finally, perform initial testing to confirm proper function and airflow, and train staff on its use and maintenance.
3. How to prevent static charge buildup in a Horizontal Laminar Flow Cabinet?
To prevent static charge buildup in a Horizontal Laminar Flow Cabinet, use antistatic wipes or mats on the work surface. Ground yourself and any equipment by using grounding straps. Additionally, maintain appropriate humidity levels in the room, as low humidity can increase static electricity.
4. How to handle spills in a Horizontal Laminar Flow Cabinet?
To handle spills in a Horizontal Laminar Flow Cabinet, follow these steps: Immediately contain the spill using absorbent materials. Clean the area with a suitable disinfectant, ensuring all contaminated surfaces are thoroughly cleaned. Dispose of waste materials according to your facility's biohazard protocols, and report the incident if necessary.
5. What are the main applications of a Horizontal Laminar Flow Cabinet?
The main applications of a Horizontal Laminar Flow Cabinet include microbiology, pharmaceutical compounding, electronics assembly, and any other processes that require a sterile and particle-free environment. These cabinets are essential in preventing contamination and ensuring the integrity of sensitive operations.
6. Are there eco-friendly options for Horizontal Laminar Flow Cabinets?
Yes, there are eco-friendly options for Horizontal Laminar Flow Cabinets. These may include energy-efficient models with low energy consumption, cabinets made from sustainable materials, and those with features such as LED lighting and programmable airflow settings to reduce environmental impact.
7. How to reduce vibrations in a Horizontal Laminar Flow Cabinet?
To reduce vibrations in a Horizontal Laminar Flow Cabinet, ensure it is placed on a stable, level surface. Use vibration-dampening pads or mounts if necessary. Regularly inspect and maintain the blower motor to prevent mechanical issues that can cause vibrations.
8. How does a laminar flow cabinet protect against contamination?
A laminar flow cabinet protects against contamination by continuously directing HEPA-filtered air over the work surface. This creates a sterile environment by removing airborne particles and microorganisms, preventing them from settling on the work area and ensuring a contaminant-free workspace.
9. Can a Horizontal Laminar Flow Cabinet be used for cell culture?
Yes, a Horizontal Laminar Flow Cabinet can be used for cell culture. It provides a sterile environment that is crucial for maintaining cell viability and preventing contamination. The horizontal airflow helps protect both the samples and the operator, ensuring reliable and reproducible results.
10. How to assess the condition of a Horizontal Laminar Flow Cabinet?
To assess the condition of a Horizontal Laminar Flow Cabinet, visually inspect the HEPA filter, pre-filters, and work surface for any damage or contamination. Conduct airflow velocity tests and particle count tests to ensure proper function. Regularly check and document the performance and maintenance activities.
11. What accessories are available for Horizontal Laminar Flow Cabinets?
Accessories available for Horizontal Laminar Flow Cabinets include:
UV sterilization lights
Adjustable stands or tables
Ergonomic chairs
Antistatic mats
Additional shelving or storage options
Magnifying lamps
12. What is the warranty period for a Horizontal Laminar Flow Cabinet?
The warranty period for a Horizontal Laminar Flow Cabinet typically ranges from one to three years, depending on the manufacturer and model. It is important to check the specific warranty details provided by the manufacturer to understand what is covered and any conditions that apply.
13. Can a Horizontal Laminar Flow Cabinet be used for handling hazardous materials?
A Horizontal Laminar Flow Cabinet is generally not suitable for handling hazardous materials, as it does not protect the operator from exposure. For handling hazardous materials, a Biological Safety Cabinet (BSC) or other specialized containment equipment is recommended to ensure both product and operator safety.
14. How to prevent cross-contamination in a Horizontal Laminar Flow Cabinet?
To prevent cross-contamination in a Horizontal Laminar Flow Cabinet, regularly clean and disinfect the work surface and interior. Avoid placing non-essential items inside the cabinet. Use proper aseptic techniques and change gloves frequently. Ensure that airflow is not obstructed and operate the cabinet at the recommended airflow settings.
15. Are there size options available for Horizontal Laminar Flow Cabinets?
Yes, Horizontal Laminar Flow Cabinets come in various sizes to suit different laboratory needs. Common sizes range from 3 feet to 9 feet in width, allowing flexibility in selecting the appropriate size based on workspace requirements and the nature of the tasks performed.
16. How much does a Horizontal Laminar Flow Cabinet cost?
The cost of a Horizontal Laminar Flow Cabinet can vary widely depending on size, features, and manufacturer. Basic models may start around $2,000 to $3,000, while larger or more advanced models can cost upwards of $10,000 to $15,000. It is important to consider the specific needs and budget when selecting a cabinet.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set