4 ft Horizontal Laminar Flow Cabinet

Reference Price:US$from $600

Short Description:

A 4 ft Horizontal Laminar Flow Cabinet is a laboratory workstation designed to provide a clean and particle-free environment by directing HEPA-filtered air horizontally across the work surface.

  • Air Flow: Horizontal flow
  • Available sizes: 4 ft
  • size: 1200×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: ULPA Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

4 ft Horizontal Laminar Flow Cabinet

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

4 ft Horizontal Laminar Flow Cabinet

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 4 ft Horizontal Laminar Flow Cabinet is a laboratory workstation designed to provide a clean and particle-free environment by directing HEPA-filtered air horizontally across the work surface. This model, typically measuring 4 feet in width, is ideal for protecting sensitive samples and processes from contamination in various applications, including microbiology, pharmaceuticals, and electronics assembly.Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. What certifications are required for Horizontal Laminar Flow Cabinets?

Horizontal Laminar Flow Cabinets typically require certifications such as ISO 14644-1 for cleanroom standards and ISO 9001 for quality management systems. Additionally, cabinets might need UL or CE certification depending on the region of use.


2. How to ensure ergonomic use of a Horizontal Laminar Flow Cabinet?

Ensuring ergonomic use of a Horizontal Laminar Flow Cabinet involves adjusting the height of the work surface, providing adequate lighting, and ensuring that tools and materials are within easy reach. It's crucial to maintain a comfortable working posture to prevent strain.


3. Can a Horizontal Laminar Flow Cabinet be used in a hospital setting?

Yes, a Horizontal Laminar Flow Cabinet can be used in a hospital setting, particularly in laboratories and pharmacies where sterile conditions are required to handle sensitive medications and samples. It helps prevent contamination and ensures a clean working environment.


4. How to measure the airflow velocity in a Horizontal Laminar Flow Cabinet?

Airflow velocity in a Horizontal Laminar Flow Cabinet can be measured using an anemometer. Place the anemometer at various points across the work surface to ensure consistent airflow. Regular monitoring helps maintain optimal performance.


5. What are the common contaminants in a Horizontal Laminar Flow Cabinet?

Common contaminants in a Horizontal Laminar Flow Cabinet include dust particles, microbes, and chemical vapors. To minimize these contaminants:

  • Regularly clean the work surface.

  • Use proper storage for materials.

  • Replace filters as recommended.


6. How to upgrade an existing Horizontal Laminar Flow Cabinet?

Upgrading an existing Horizontal Laminar Flow Cabinet can involve installing new HEPA filters, adding UV sterilization lights, or integrating advanced monitoring systems. Consult the manufacturer for compatible upgrades that meet your specific needs.


7. How does a Horizontal Laminar Flow Cabinet work?

A Horizontal Laminar Flow Cabinet works by drawing ambient air through a HEPA filter, which removes particulates and contaminants. The filtered air is then directed horizontally across the work surface, creating a sterile environment that protects samples and processes from airborne contamination.


8. What are the common accessories for a Horizontal Laminar Flow Cabinet?

Common accessories for a Horizontal Laminar Flow Cabinet include:

  • UV sterilization lights

  • Adjustable work surfaces

Magnifying lamps These accessories enhance functionality and user comfort.


9. How do I choose the right laminar flow cabinet for my needs?

Choosing the right laminar flow cabinet involves considering factors such as the type of work being conducted, the size and layout of the workspace, and the level of contamination control required. Consulting with manufacturers and reviewing technical specifications can also help in making an informed decision.


10. Are there portable Horizontal Laminar Flow Cabinets?

Yes, there are portable Horizontal Laminar Flow Cabinets available. These models are designed for easy mobility and can be used in various locations within a facility, providing flexible sterile environments where needed.


11. How to prevent cross-contamination in a Horizontal Laminar Flow Cabinet?

Preventing cross-contamination in a Horizontal Laminar Flow Cabinet involves regular cleaning of the work surface, using proper aseptic techniques, and segregating different types of samples. Additionally, replace filters as recommended and avoid overcrowding the workspace.


12. What are the operational guidelines for a Horizontal Laminar Flow Cabinet?

Operational guidelines for a Horizontal Laminar Flow Cabinet include:

  • Regularly inspecting and replacing filters.

  • Avoiding sudden movements that disturb airflow.

Ensuring all materials are clean before placing them inside. These practices help maintain a sterile environment.


13. How to replace the filters in a Horizontal Laminar Flow Cabinet?

To replace the filters in a Horizontal Laminar Flow Cabinet, first, turn off the cabinet and disconnect it from the power source. Remove the old filters according to the manufacturer's instructions and install new HEPA filters. Ensure they are properly seated and secure.


14. What are the benefits of a dual-filter system in a Horizontal Laminar Flow Cabinet?

A dual-filter system in a Horizontal Laminar Flow Cabinet offers enhanced contamination control by using a pre-filter to capture larger particles and a HEPA filter for finer particulates. This system extends the life of the HEPA filter and improves overall air quality.


15. What is the lifespan of a Horizontal Laminar Flow Cabinet?

The lifespan of a Horizontal Laminar Flow Cabinet depends on usage and maintenance but generally ranges from 10 to 15 years. Regular cleaning, timely filter replacements, and adherence to operational guidelines can help extend its functional life.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.