MENU
X

5 ft Horizontal Laminar Flow Cabinet

Reference Price:US$from $1000.00

Short Description:

A 5 ft Horizontal Laminar Flow Cabinet is a specialized laboratory workstation designed to create a sterile environment by directing HEPA-filtered air horizontally across the work surface.

  • Air Flow: Horizontal flow
  • Available sizes: 5 ft
  • size: 1500×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: ULPA Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

5 ft Horizontal Laminar Flow Cabinet

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

5 ft Horizontal Laminar Flow Cabinet

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 5 ft Horizontal Laminar Flow Cabinet is a specialized laboratory workstation designed to create a sterile environment by directing HEPA-filtered air horizontally across the work surface. Measuring 5 feet in width, it is ideal for protecting sensitive samples and processes from contamination in various applications such as microbiology, pharmaceuticals, and electronics assembly. This cabinet ensures a clean, particle-free workspace, enhancing safety and reliability in laboratory operations.Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. How to perform a visual inspection of a Horizontal Laminar Flow Cabinet?

To perform a visual inspection of a Horizontal Laminar Flow Cabinet, start by ensuring the cabinet is turned off and unplugged. Examine the exterior for any physical damage, such as dents or scratches. Open the front shield and inspect the interior surfaces for cleanliness and integrity. Check the condition of the pre-filters and HEPA filters for signs of wear or contamination. Ensure that all control switches, lights, and gauges are functioning properly.


2. How to set up a Horizontal Laminar Flow Cabinet in a laboratory?

Setting up a Horizontal Laminar Flow Cabinet involves selecting a suitable location with minimal air disturbance and ensuring a stable, level surface. Unpack the cabinet carefully, following the manufacturer's instructions. Place it in the designated area, connect it to a power source, and verify that the airflow direction is correct. Calibrate the airflow using the built-in controls and ensure all safety features are operational.


3. What materials are used in the construction of laminar flow cabinets?

Laminar flow cabinets are typically constructed using the following materials:

  • Stainless steel for the work surface and exterior panels.

  • Glass or acrylic for the front shield.

  • HEPA filters for air filtration.

Aluminum frames and supports for structural integrity.


4. What are the main applications of a Horizontal Laminar Flow Cabinet?

Horizontal Laminar Flow Cabinets are used primarily in laboratories for applications that require a sterile environment. These include cell culture, microbiological work, pharmaceutical preparations, and any procedures involving non-pathogenic materials. They provide a controlled, contaminant-free workspace by filtering incoming air through HEPA filters and maintaining a consistent laminar airflow across the work surface.


5. What is the noise level of a typical Horizontal Laminar Flow Cabinet?

The noise level of a typical Horizontal Laminar Flow Cabinet is generally between 50 to 65 decibels, which is comparable to a normal conversation. This noise level can vary based on the model and the fan speed settings.


6. How often should HEPA filters be replaced in a laminar flow cabinet?

HEPA filters in a laminar flow cabinet should be replaced every 1 to 3 years, depending on usage and environmental conditions. Regular monitoring and efficiency tests can help determine the optimal replacement schedule.


7. What is the difference between horizontal and vertical laminar flow cabinets?

Horizontal Laminar Flow Cabinets direct air horizontally from the back of the cabinet towards the user, providing a sterile airflow across the work surface. Vertical Laminar Flow Cabinets direct air vertically from the top of the cabinet downwards, protecting both the work surface and the user. The choice between the two depends on the specific application and workspace requirements.


8. How to replace the filters in a Horizontal Laminar Flow Cabinet?

To replace the filters in a Horizontal Laminar Flow Cabinet, first, turn off the unit and unplug it. Remove the front shield or access panel to expose the filters. Carefully remove the pre-filters and HEPA filters, avoiding any contact with the filtered surfaces. Install the new filters in the same orientation, ensuring a proper seal. Reassemble the cabinet and perform a test run to verify the airflow and filtration efficiency.


9. What are the benefits of using a Horizontal Laminar Flow Cabinet?

Using a Horizontal Laminar Flow Cabinet provides several benefits:

  • Ensures a contaminant-free work environment.

  • Protects samples and processes from airborne particulates.

Enhances precision and reliability in sensitive applications. These benefits make it an essential tool in various scientific and industrial fields.


10. How does a Horizontal Laminar Flow Cabinet work?

A Horizontal Laminar Flow Cabinet works by drawing air through a pre-filter and passing it through a HEPA filter. The filtered air is then directed horizontally over the work surface, creating a sterile environment. This laminar airflow prevents contamination by sweeping away particulates and maintaining a consistent, unidirectional flow across the workspace.


11. What are the regulatory standards for Horizontal Laminar Flow Cabinets?

Regulatory standards for Horizontal Laminar Flow Cabinets include ISO 14644 for cleanroom environments, NSF/ANSI 49 for biosafety cabinetry, and various local or industry-specific guidelines. These standards ensure that the cabinets provide adequate contamination control and safety for laboratory personnel.


12. How do I maintain and clean a Horizontal Laminar Flow Cabinet?

Maintaining and cleaning a Horizontal Laminar Flow Cabinet involves regular cleaning of the work surface with appropriate disinfectants, checking and replacing filters as needed, and ensuring that fans and blowers are functioning correctly. Periodic professional servicing and certification are also recommended to maintain optimal performance.


13. How to optimize the performance of a Horizontal Laminar Flow Cabinet?

To optimize the performance of a Horizontal Laminar Flow Cabinet:

  • Regularly clean and disinfect the interior surfaces.

  • Replace filters according to the manufacturer's schedule.

  • Avoid cluttering the work surface to maintain proper airflow.

  • Perform routine maintenance checks on all components.


14. How do I test and validate the performance of my laminar flow cabinet?

Testing and validating the performance of a laminar flow cabinet involves conducting airflow velocity tests, HEPA filter integrity tests, and particle counting. These tests ensure that the cabinet meets the required standards and provides a contaminant-free environment. Regular validation should be performed by certified professionals.


15. How much does a Horizontal Laminar Flow Cabinet cost?

The cost of a Horizontal Laminar Flow Cabinet varies based on size, features, and manufacturer. Prices typically range from $2,000 to $10,000. It's important to consider the specific needs and compliance requirements when choosing a cabinet.


16. What are the benefits of a dual-filter system in a Horizontal Laminar Flow Cabinet?

A dual-filter system in a Horizontal Laminar Flow Cabinet offers enhanced protection by using both a pre-filter and a HEPA filter. The pre-filter captures larger particles, extending the life of the HEPA filter. This setup improves overall filtration efficiency and ensures a longer operational lifespan for the cabinet.

Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.