3 ft Medical Clean bench-Single side, Vertical Flow

Reference Price:US$From $500

Short Description:

A 3 ft Medical Clean Bench is a compact, sterile workstation designed for laboratory applications requiring a contamination-free environment.

  • Air Flow: Vertical flow
  • Available sizes: 3 ft
  • size: 1000×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: ULPA Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

3 ft Medical Clean bench-Single side, Vertical Flow

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

3 ft Medical Clean bench-Single side, Vertical Flow

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 3 ft Medical Clean Bench is a compact, sterile workstation designed for laboratory applications requiring a contamination-free environment. It features a HEPA filter that provides laminar airflow, ensuring a clean workspace for sensitive tasks. Ideal for small laboratories, this bench offers reliable performance in a space-efficient design..Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. What is a medical clean bench?

A medical clean bench is a workstation designed to provide a sterile environment for various laboratory tasks. It utilizes HEPA-filtered air to create a contamination-free workspace, ensuring that sensitive procedures are performed in a clean environment.


2. How does a vertical laminar flow cabinet work?

A vertical laminar flow cabinet works by drawing air through a HEPA filter and then pushing it downwards in a vertical direction over the work surface. This creates a continuous flow of clean air, which helps to protect the work area from contaminants.


3. What are the benefits of a vertical laminar flow cabinet?

Vertical laminar flow cabinets offer several benefits:

  • Enhanced protection from contaminants

  • Suitable for a wide range of applications

  • Ergonomic design

These cabinets provide a clean airflow pattern that reduces the risk of cross-contamination, making them ideal for sensitive laboratory tasks.


4. How to maintain a medical clean bench?

Maintaining a medical clean bench involves several key steps:

  • Regularly clean the surfaces with appropriate disinfectants.

  • Replace HEPA filters as per the manufacturer's guidelines.

  • Perform routine airflow checks to ensure optimal performance.

Proper maintenance ensures the clean bench continues to provide a sterile environment for laboratory work.


5. What is the difference between a clean bench and a biosafety cabinet?

The primary difference between a clean bench and a biosafety cabinet lies in their function and airflow patterns. A clean bench provides a sterile work environment by directing HEPA-filtered air over the workspace. In contrast, a biosafety cabinet protects both the user and the environment from hazardous materials by containing and filtering contaminated air.


6. How often should HEPA filters be replaced in a vertical laminar flow cabinet?

HEPA filters in a vertical laminar flow cabinet should generally be replaced every 1-3 years, depending on the frequency of use and the level of contaminants in the work environment. Regular inspections and performance tests can help determine the appropriate replacement schedule.


7. Can a vertical laminar flow cabinet be used for tissue culture?

Yes, a vertical laminar flow cabinet can be used for tissue culture. The sterile environment provided by the HEPA-filtered airflow is ideal for preventing contamination during tissue culture procedures.


8. What is the airflow pattern in a vertical laminar flow cabinet?

In a vertical laminar flow cabinet, the airflow pattern is directed vertically from the top of the cabinet downwards over the work surface. This vertical flow helps to push contaminants away from the work area and towards the exhaust filters, maintaining a clean environment.


9. How to properly clean a medical clean bench?

To properly clean a medical clean bench:

  • Turn off the airflow and unplug the unit.

  • Use a lint-free cloth and a suitable disinfectant to wipe down all surfaces.

  • Pay special attention to corners and hard-to-reach areas.

Allow the surfaces to dry completely before turning the unit back on to ensure a sterile environment.


10. What are the best brands for medical clean benches?

The best brands for medical clean benches include:

  • Deiiang

  • Esco

  • Labconco

These brands are known for their high-quality construction, reliable performance, and adherence to industry standards.


11. How to install a vertical laminar flow cabinet?

Installing a vertical laminar flow cabinet involves several steps:

  • Choose a suitable location with adequate space and proper ventilation.

  • Assemble the cabinet according to the manufacturer’s instructions.

  • Connect the unit to a power source and ensure it is level.

Perform initial performance tests to confirm proper airflow and filter integrity before use.


12. What is the purpose of a medical clean bench?

The purpose of a medical clean bench is to provide a sterile environment for various laboratory procedures. It helps to protect sensitive samples and processes from contamination by using HEPA-filtered air to maintain a clean workspace.


13. How to measure airflow in a vertical laminar flow cabinet?

Airflow in a vertical laminar flow cabinet can be measured using an anemometer. Place the anemometer at various points on the work surface to ensure consistent airflow. The readings should match the manufacturer’s specifications for optimal performance.


14. What is the difference between horizontal and vertical laminar flow cabinets?

The main difference between horizontal and vertical laminar flow cabinets is the direction of airflow. Horizontal laminar flow cabinets direct air horizontally across the work surface, while vertical laminar flow cabinets direct air downwards from above. Vertical cabinets are often preferred for tasks requiring sterility, as they reduce the risk of cross-contamination.


15. How much does a vertical laminar flow cabinet cost?

The cost of a vertical laminar flow cabinet can vary widely based on size, features, and brand. Generally, prices range from $2,000 to $10,000. High-end models with additional features may cost even more.


16. How to troubleshoot a medical clean bench?

To troubleshoot a medical clean bench, follow these steps:

  • Check the power supply and ensure the unit is plugged in.

  • Inspect the HEPA filters for clogs or damage.

  • Verify the airflow with an anemometer.

If issues persist, consult the manufacturer’s manual or contact technical support for further assistance.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.