7 ft Medical Clean bench-Single side, Vertical Flow
Reference Price:US$From $1200




Cleanroom
7 ft Medical Clean bench-Single side, Vertical Flow
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
7 ft Medical Clean bench-Single side, Vertical Flow
Validation
Installation & Validation
Find Similar Products
-
7 ft Medical Clean bench-Single side, Ve
US$
Min. Order:1 Set -
6 ft Medical Clean bench
US$
Min. Order:1 Set -
5 ft Medical Clean bench- Vertical Flow
US$
Min. Order:1 Set -
4 ft Medical Clean bench-Single side
US$
Min. Order:1 Set -
3 ft Medical Clean bench-Single side, Ve
US$
Min. Order:1 Set -
8 ft Medical Clean bench-Vertical Flow
US$
Min. Order:1 Set
Product Briefing
A 7 ft Medical Clean Bench offers an expansive, sterile workspace ideal for extensive laboratory procedures. It utilizes advanced HEPA filtration to ensure a consistent laminar airflow, maintaining a contamination-free environment across a larger surface area. This bench is designed for high-performance contamination control, accommodating a wide range of medical and research applications with its ample workspace and robust design..Here’s a detailed overview of its features, functions, and benefits:
Applications
Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.
Pharmaceuticals: Used in the preparation and compounding of sterile medications.
Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.
Research: Provides a clean environment for various scientific experiments and procedures.
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Features
High-Quality Construction
| |
Quiet Operation
| |
ULPA Filter
| |
Energy-efficient
| |
GDC™ Antimicrobial Powder Coating
|
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
Stainless Steel Orifice Tabletop
ULPA Ultra GX Filter
UV Germicidal Lamps
De-static equipment
Support Stand with Caster Wheels
FAQ
1. Can a vertical laminar flow cabinet be used for cell culture?
Yes, a vertical laminar flow cabinet can be used for cell culture. It provides a sterile environment by directing filtered air downward, which helps to prevent contamination, ensuring the integrity of cell cultures.
2. What are the common issues with medical clean benches?
Common issues with medical clean benches include inconsistent airflow due to clogged filters, excessive noise levels, and difficulties in maintaining sterility. Regular maintenance and cleaning are essential to address these issues and ensure optimal performance.
3. How to reduce energy consumption in a vertical laminar flow cabinet?
To reduce energy consumption in a vertical laminar flow cabinet, use energy-efficient components, ensure regular maintenance to keep filters clean, and turn off the cabinet when not in use. Implementing these measures can significantly lower energy usage.
4. What are the best brands for medical clean benches?
Some of the best brands for medical clean benches include Thermo Fisher Scientific, Labconco, and Esco. These brands are renowned for their reliable performance, robust construction, and advanced filtration systems.
5. How to perform a risk assessment for using a medical clean bench?
Performing a risk assessment for using a medical clean bench involves identifying potential hazards, evaluating the risks associated with those hazards, and implementing control measures. Regularly updating the risk assessment ensures ongoing safety and compliance.
6. What are the key features to look for in a vertical laminar flow cabinet?
Key features to look for in a vertical laminar flow cabinet include high-efficiency HEPA or ULPA filters, adjustable airflow settings, ergonomic design, and low noise levels. These features contribute to maintaining a sterile environment and user comfort.
7. What are the environmental impacts of using a medical clean bench?
The environmental impacts of using a medical clean bench primarily involve energy consumption and the disposal of used filters. Opting for energy-efficient models and following proper disposal protocols for filters can help mitigate these impacts.
8. What are the different models of vertical laminar flow cabinets available?
Different models of vertical laminar flow cabinets include bench-top models, stand-alone models, and customizable models with various sizes and features. Each model is designed to cater to specific laboratory requirements and space constraints.
9. How to test the effectiveness of a vertical laminar flow cabinet?
To test the effectiveness of a vertical laminar flow cabinet, conduct a particle count test using a particle counter. This test measures the number of particles in the air before and after filtration, ensuring the cabinet meets cleanliness standards.
10. How much does a vertical laminar flow cabinet cost?
The cost of a vertical laminar flow cabinet typically ranges from $2,000 to $10,000, depending on the size, features, and brand. Higher-end models with advanced features are usually more expensive.
11. How to select the right vertical laminar flow cabinet for your lab?
When selecting a vertical laminar flow cabinet for your lab, consider factors such as the size of the workspace, the type of filtration required, the noise level, and your budget. It's essential to choose a model that meets your specific needs and complies with industry standards.
12. How to improve lighting in a medical clean bench?
To improve lighting in a medical clean bench, install energy-efficient LED lights that provide bright, even illumination. Ensure the lighting is positioned to minimize shadows and reflections, enhancing visibility and reducing eye strain.
13. How to replace the pre-filter in a vertical laminar flow cabinet?
To replace the pre-filter in a vertical laminar flow cabinet, first, turn off the cabinet and unplug it. Then, locate the pre-filter compartment, remove the old filter, and insert a new one. Ensure the filter is properly seated and secure before restarting the cabinet.
14. What accessories are available for medical clean benches?
Accessories available for medical clean benches include:
UV sterilization lights.
Ergonomic seating.
Adjustable shelving. These accessories enhance the functionality and comfort of the workspace.
15. What training is required for using a medical clean bench?
Training for using a medical clean bench should cover proper operation, maintenance procedures, and safety protocols. Users should be familiar with how to handle and dispose of contaminants and how to troubleshoot common issues.
16. Can a vertical laminar flow cabinet be used in a medical lab?
Yes, a vertical laminar flow cabinet can be used in a medical lab. It provides a sterile environment that is essential for various medical procedures, including cell culture, preparation of sterile solutions, and handling of sensitive materials.
17. What are the benefits of using a vertical laminar flow cabinet in a lab?
The benefits of using a vertical laminar flow cabinet in a lab include maintaining a sterile environment, reducing the risk of contamination, and protecting both the samples and the operator. These cabinets are essential for ensuring the integrity of sensitive experiments and procedures.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set