MENU
X

7 ft Medical Clean bench-Single side, Vertical Flow

Reference Price:US$From $1200

Short Description:

A 7 ft Medical Clean Bench offers an expansive, sterile workspace ideal for extensive laboratory procedures. It utilizes advanced HEPA filtration to ensure a consistent laminar airflow, maintaining a contamination-free environment across a larger surface area.

  • Air Flow: Vertical flow
  • Available sizes: 7 ft
  • size: 2100×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: Hepa Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

7 ft Medical Clean bench-Single side, Vertical Flow

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

7 ft Medical Clean bench-Single side, Vertical Flow

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 7 ft Medical Clean Bench offers an expansive, sterile workspace ideal for extensive laboratory procedures. It utilizes advanced HEPA filtration to ensure a consistent laminar airflow, maintaining a contamination-free environment across a larger surface area. This bench is designed for high-performance contamination control, accommodating a wide range of medical and research applications with its ample workspace and robust design..Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. Can a vertical laminar flow cabinet be used for cell culture?

Yes, a vertical laminar flow cabinet can be used for cell culture. It provides a sterile environment by directing filtered air downward, which helps to prevent contamination, ensuring the integrity of cell cultures.


2. What are the common issues with medical clean benches?

Common issues with medical clean benches include inconsistent airflow due to clogged filters, excessive noise levels, and difficulties in maintaining sterility. Regular maintenance and cleaning are essential to address these issues and ensure optimal performance.


3. How to reduce energy consumption in a vertical laminar flow cabinet?

To reduce energy consumption in a vertical laminar flow cabinet, use energy-efficient components, ensure regular maintenance to keep filters clean, and turn off the cabinet when not in use. Implementing these measures can significantly lower energy usage.


4. What are the best brands for medical clean benches?

Some of the best brands for medical clean benches include Thermo Fisher Scientific, Labconco, and Esco. These brands are renowned for their reliable performance, robust construction, and advanced filtration systems.


5. How to perform a risk assessment for using a medical clean bench?

Performing a risk assessment for using a medical clean bench involves identifying potential hazards, evaluating the risks associated with those hazards, and implementing control measures. Regularly updating the risk assessment ensures ongoing safety and compliance.


6. What are the key features to look for in a vertical laminar flow cabinet?

Key features to look for in a vertical laminar flow cabinet include high-efficiency HEPA or ULPA filters, adjustable airflow settings, ergonomic design, and low noise levels. These features contribute to maintaining a sterile environment and user comfort.


7. What are the environmental impacts of using a medical clean bench?

The environmental impacts of using a medical clean bench primarily involve energy consumption and the disposal of used filters. Opting for energy-efficient models and following proper disposal protocols for filters can help mitigate these impacts.


8. What are the different models of vertical laminar flow cabinets available?

Different models of vertical laminar flow cabinets include bench-top models, stand-alone models, and customizable models with various sizes and features. Each model is designed to cater to specific laboratory requirements and space constraints.


9. How to test the effectiveness of a vertical laminar flow cabinet?

To test the effectiveness of a vertical laminar flow cabinet, conduct a particle count test using a particle counter. This test measures the number of particles in the air before and after filtration, ensuring the cabinet meets cleanliness standards.


10. How much does a vertical laminar flow cabinet cost?

The cost of a vertical laminar flow cabinet typically ranges from $2,000 to $10,000, depending on the size, features, and brand. Higher-end models with advanced features are usually more expensive.


11. How to select the right vertical laminar flow cabinet for your lab?

When selecting a vertical laminar flow cabinet for your lab, consider factors such as the size of the workspace, the type of filtration required, the noise level, and your budget. It's essential to choose a model that meets your specific needs and complies with industry standards.


12. How to improve lighting in a medical clean bench?

To improve lighting in a medical clean bench, install energy-efficient LED lights that provide bright, even illumination. Ensure the lighting is positioned to minimize shadows and reflections, enhancing visibility and reducing eye strain.


13. How to replace the pre-filter in a vertical laminar flow cabinet?

To replace the pre-filter in a vertical laminar flow cabinet, first, turn off the cabinet and unplug it. Then, locate the pre-filter compartment, remove the old filter, and insert a new one. Ensure the filter is properly seated and secure before restarting the cabinet.


14. What accessories are available for medical clean benches?

Accessories available for medical clean benches include:

  • UV sterilization lights.

  • Ergonomic seating.

Adjustable shelving. These accessories enhance the functionality and comfort of the workspace.


15. What training is required for using a medical clean bench?

Training for using a medical clean bench should cover proper operation, maintenance procedures, and safety protocols. Users should be familiar with how to handle and dispose of contaminants and how to troubleshoot common issues.


16. Can a vertical laminar flow cabinet be used in a medical lab?

Yes, a vertical laminar flow cabinet can be used in a medical lab. It provides a sterile environment that is essential for various medical procedures, including cell culture, preparation of sterile solutions, and handling of sensitive materials.


17. What are the benefits of using a vertical laminar flow cabinet in a lab?

The benefits of using a vertical laminar flow cabinet in a lab include maintaining a sterile environment, reducing the risk of contamination, and protecting both the samples and the operator. These cabinets are essential for ensuring the integrity of sensitive experiments and procedures.

Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.