1` FYCLS chemical raw material weighing room-PLC control, touch screen, polymer equalization membrane
Reference Price:US$
Min. Order:Cleanroom
1` FYCLS chemical raw material weighing room-PLC control, touch screen, polymer equalization membrane
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
1` FYCLS chemical raw material weighing room-PLC control, touch screen, polymer equalization membrane
Validation
Installation & Validation
Find Similar Products
-
3` FYCLS chemical raw material weighing
US$
Min. Order: -
4` FYCLS chemical raw material weighing
US$
Min. Order: -
5` FYCLS chemical raw material weighing
US$
Min. Order: -
6` FYCLS chemical raw material weighing
US$
Min. Order: -
1` FYCLS chemical raw material weighing
US$
Min. Order: -
2` FYCLS chemical raw material weighing
US$
Min. Order:
Detail
Neg Furls Negative Pressure Weighing Chamber is a special equipment designed for accurate weighing of powdery and granular materials in the laboratory. It extracts air from the weighing area through negative pressure to form a low-pressure environment, which effectively prevents the intrusion of dust, moisture and other impurities from the outside and ensures the accuracy and safety of weighing. This equipment is widely used in chemical, pharmaceutical, food, agriculture and other fields, especially in line with the production requirements of GMP (Good Manufacturing Practice) in pharmaceutical factories.
Negative Pressure Weighing Chamber Specifications | KLDC-FYCLS 1200 | KLDC-FYCLS 1300 | KLDC-FYCLS 1400 | KLDC-FYCLS 1500 | KLDC-FYCLS 1600 | KLDC-FYCLS 2700 |
---|---|---|---|---|---|---|
Overall Dimension(mm) | 1200X1200x2500 | 1300X1300X2500 | 1500x1300X2500 | 2000x1300Xx2500 | 2000X1500X2500 | 2000x1800X2500 |
Size of working area (mm) | 1100X700X2000 | 1200x800X2000 | 1400X700X2000 | 1900x800X2000 | 1900X1000X2000 | 1900X1300X2000 |
Rated air volume (m°/h) | 1300~1500 | 1600~1800 | 2000~2200 | 2500~2700 | 3400-3600 | 4500~4900 |
Wind speed (m/s) | 0.45+20% | 0.45+20% | 0.45+20% | 0.45+20% | 0.45+20% | 0.45+20% |
cleanliness level | A级 | A级 | A级 | A级 | A级 | A级 |
Noise (dB) | 72 | 72 | 72 | 72 | 72 | 72 |
Illumination (Lux) | >300 | >300 | >300 | >300 | >300 | >300 |
control method | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control |
Power (KW) | 0.75 | 0.75 | 1.5 | 1.5 | 2.2 | 2.2 |
Note: Negative pressure weighing room can be made according to customer requirements for non-standard products.
Specification
Neg Furls Negative Pressure Weighing Chamber Product Features in Detail
Working area design
Material and structure: the working area is made of stainless steel 304, thickness is 1.2mm, the surface is processed by oil drawing short wire, the internal arc angle connection, no dead angle, not only ensure the sealing of the working area, but also enhance the overall neatness and aesthetics.
Wind speed control
Manual frequency conversion system: Through the manual frequency conversion system, it can ensure that the wind speed in the main working area is always in the state of uniform operation, adapting to different weighing needs and ensuring the accuracy and stability of weighing.
Filter differential pressure display
Real-time monitoring: Equipped with a filter differential pressure display device, it can monitor the effective running condition of each filter in real time, which is convenient for timely detection and replacement of filters that are about to fail, ensuring the continuous and efficient operation of the equipment.
Air duct design
Unique design: The unique air duct design effectively controls the working noise of the whole machine, provides a quiet weighing environment, and also reduces energy consumption, realizing the double optimization of environmental protection and practicality.
The Neg Furls Negative Pressure Weighing Chamber meets the stringent requirements of laboratories for high-precision weighing with its outstanding design and performance, not only guaranteeing a clean weighing environment, but also providing a convenient operating experience and efficient maintenance management, making it an indispensable and ideal choice for laboratories.
Material Selection:
Neg Furls negative pressure weighing chambers are usually made of materials that meet national standards to ensure good corrosion, wear and high temperature resistance. Common materials are 304 or 316 stainless steel to suit different usage scenarios. In the absence of special requirements, the choice of material can be made according to the project budget, but it is recommended to choose a better quality material to facilitate long-term maintenance and use.
Structural design:
The design of Neg Furls negative pressure weighing chambers focuses on structural rationality and durability. Its structure usually includes the working area, return air box, fan box, air outlet box and external box and other parts. The wall panels of the working area are made of stainless steel, and the internal rounded corners are connected without dead corners to ensure the sealing and neatness of the working area. The equipment adopts modular design, easy to assemble and disassemble on site, and has optional configurations such as PVC strip curtain on the front side.
Filtration system:
The Neg Furls Negative Pressure Weighing Chamber is equipped with a highly efficient filtration system consisting of primary, intermediate, and high efficiency filters, as well as a homogenizing membrane. These filters effectively capture airborne particles to ensure clean air that meets GMP and other standards. Information such as differential pressure, air velocity and temperature and humidity of the filters can be monitored in real time through the control system to ensure the normal operation of the equipment.
Control System:
The control system of Neg Furls Negative Pressure Weighing Room adopts advanced PLC control and touch screen operation, which can realize the functions of starting and stopping the fan and adjusting the wind speed. The system is also equipped with wind speed sensors, differential pressure sensors, etc. to monitor and adjust the status of the equipment in real time to ensure the stability of the weighing environment.
Principle
The core working principle of the Neg Furls Negative Pressure Weighing Chamber is its unique vertical unidirectional airflow design. This design allows part of the clean air to circulate within the working area, while the remainder is exhausted into the surrounding area, creating a negative pressure within the working area and effectively preventing the spread of contaminants and cross contamination. Specifically, the air is first pre-filtered through a primary filter to remove larger dust particles, then filtered through an intermediate filter for secondary filtration, and finally, under the pressure of a centrifugal fan, it passes through a high-efficiency filter to meet the cleanliness requirements and ensure the purity of the air.
Accessories
Options.
1 | Wind Speed Sensor | ![]() |
2 | Differential Pressure Sensor | |
3 | converter | |
4 | touchscreens | |
5 | PLC control | ![]() |
6 | Polymer homogeneous membrane |
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order: -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order: -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order: -
Clean bench
US$600-2000 USD/Unit
Min. Order: -
Air Filter
US$3-50 USD/Unit
Min. Order: -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order: -
Pass Box
US$200-500 USD/Unit
Min. Order: -
FFU
US$135-350 USD/Unit
Min. Order: -
Fume Hood
US$700-1500 USD/Unit
Min. Order: -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order: -
Clean room floor
US$5-20 USD/Sq.
Min. Order: -
Clean room ceiling
US$
Min. Order: