MENU
X

1` FYCLS chemical raw material weighing room-PLC control, touch screen, polymer equalization membrane

Reference Price:US$

Min. Order:

Short Description:

  • Worktop Material:
  • sizes:
  • widths:
  • depths:
  • Front window opening height:
  • Power Adaptation:
  • noise:
  • lights:
  • exhaust volume:
  • surface air velocity:
  • production state:
  • customs code:
  • Product Certification:
  • Applicable area:

Cleanroom

1` FYCLS chemical raw material weighing room-PLC control, touch screen, polymer equalization membrane

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

1` FYCLS chemical raw material weighing room-PLC control, touch screen, polymer equalization membrane

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Detail

Neg Furls Negative Pressure Weighing Chamber is a special equipment designed for accurate weighing of powdery and granular materials in the laboratory. It extracts air from the weighing area through negative pressure to form a low-pressure environment, which effectively prevents the intrusion of dust, moisture and other impurities from the outside and ensures the accuracy and safety of weighing. This equipment is widely used in chemical, pharmaceutical, food, agriculture and other fields, especially in line with the production requirements of GMP (Good Manufacturing Practice) in pharmaceutical factories.

Negative Pressure Weighing Chamber SpecificationsKLDC-FYCLS 1200
KLDC-FYCLS 1300KLDC-FYCLS 1400
KLDC-FYCLS 1500KLDC-FYCLS 1600KLDC-FYCLS 2700
Overall Dimension(mm)1200X1200x25001300X1300X25001500x1300X25002000x1300Xx25002000X1500X25002000x1800X2500
Size of working area (mm)1100X700X20001200x800X20001400X700X20001900x800X20001900X1000X20001900X1300X2000
Rated air volume (m°/h)1300~15001600~18002000~22002500~27003400-36004500~4900
Wind speed (m/s)0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%
cleanliness levelA级A级A级A级A级A级
Noise (dB)727272727272
Illumination (Lux)>300>300>300>300>300>300
control method

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Power (KW)0.750.751.51.52.22.2


Note: Negative pressure weighing room can be made according to customer requirements for non-standard products. 

Specification

Neg Furls Negative Pressure Weighing Chamber Product Features in Detail

  • Working area design

Material and structure: the working area is made of stainless steel 304, thickness is 1.2mm, the surface is processed by oil drawing short wire, the internal arc angle connection, no dead angle, not only ensure the sealing of the working area, but also enhance the overall neatness and aesthetics.

  • Wind speed control

Manual frequency conversion system: Through the manual frequency conversion system, it can ensure that the wind speed in the main working area is always in the state of uniform operation, adapting to different weighing needs and ensuring the accuracy and stability of weighing.

  • Filter differential pressure display

 Real-time monitoring: Equipped with a filter differential pressure display device, it can monitor the effective running condition of each filter in real time, which is convenient for timely detection and replacement of filters that are about to fail, ensuring the continuous and efficient operation of the equipment.

  • Air duct design

Unique design: The unique air duct design effectively controls the working noise of the whole machine, provides a quiet weighing environment, and also reduces energy consumption, realizing the double optimization of environmental protection and practicality.

The Neg Furls Negative Pressure Weighing Chamber meets the stringent requirements of laboratories for high-precision weighing with its outstanding design and performance, not only guaranteeing a clean weighing environment, but also providing a convenient operating experience and efficient maintenance management, making it an indispensable and ideal choice for laboratories.


  • Material Selection:

Neg Furls negative pressure weighing chambers are usually made of materials that meet national standards to ensure good corrosion, wear and high temperature resistance. Common materials are 304 or 316 stainless steel to suit different usage scenarios. In the absence of special requirements, the choice of material can be made according to the project budget, but it is recommended to choose a better quality material to facilitate long-term maintenance and use.

  • Structural design:

The design of Neg Furls negative pressure weighing chambers focuses on structural rationality and durability. Its structure usually includes the working area, return air box, fan box, air outlet box and external box and other parts. The wall panels of the working area are made of stainless steel, and the internal rounded corners are connected without dead corners to ensure the sealing and neatness of the working area. The equipment adopts modular design, easy to assemble and disassemble on site, and has optional configurations such as PVC strip curtain on the front side.

  • Filtration system:

The Neg Furls Negative Pressure Weighing Chamber is equipped with a highly efficient filtration system consisting of primary, intermediate, and high efficiency filters, as well as a homogenizing membrane. These filters effectively capture airborne particles to ensure clean air that meets GMP and other standards. Information such as differential pressure, air velocity and temperature and humidity of the filters can be monitored in real time through the control system to ensure the normal operation of the equipment.

  • Control System:

The control system of Neg Furls Negative Pressure Weighing Room adopts advanced PLC control and touch screen operation, which can realize the functions of starting and stopping the fan and adjusting the wind speed. The system is also equipped with wind speed sensors, differential pressure sensors, etc. to monitor and adjust the status of the equipment in real time to ensure the stability of the weighing environment.

负压称量室配置图


Principle

The core working principle of the Neg Furls Negative Pressure Weighing Chamber is its unique vertical unidirectional airflow design. This design allows part of the clean air to circulate within the working area, while the remainder is exhausted into the surrounding area, creating a negative pressure within the working area and effectively preventing the spread of contaminants and cross contamination. Specifically, the air is first pre-filtered through a primary filter to remove larger dust particles, then filtered through an intermediate filter for secondary filtration, and finally, under the pressure of a centrifugal fan, it passes through a high-efficiency filter to meet the cleanliness requirements and ensure the purity of the air.

负压称量室原理图


Accessories

Options. 



1


Wind Speed Sensor 

风速传感器


2


Differential Pressure Sensor 

压差传感器


3


converter

微信截图_20240626191907.jpg


4


touchscreens

触摸屏


5


PLC control

PLC控制系统


6


 Polymer homogeneous membrane

 高分子均流膜



Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.