MENU
X

6` FYCLS Negative Pressure Weighing Hood-Wind Speed Sensor, Wind Pressure Sensor, Inverter

Reference Price:US$

Min. Order:

Short Description:

Negative pressure weighing chambers are commonly used in laboratories for the precise weighing of powdered, granular and flocculent articles.

  • Worktop Material:
  • sizes:
  • widths:
  • depths:
  • Front window opening height:
  • Power Adaptation:
  • noise:
  • lights:
  • exhaust volume:
  • surface air velocity:
  • production state:
  • customs code:
  • Product Certification:
  • Applicable area:

Cleanroom

6` FYCLS Negative Pressure Weighing Hood-Wind Speed Sensor, Wind Pressure Sensor, Inverter

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

6` FYCLS Negative Pressure Weighing Hood-Wind Speed Sensor, Wind Pressure Sensor, Inverter

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Detail

Negative pressure weighing chambers are commonly used in laboratories for the precise weighing of powdered, granular and flocculent articles. They work on the principle of negative pressure technology, whereby air is extracted from the hood or chamber to create a low-pressure environment for accurate weighing of items.



Negative Pressure Weighing Chamber SpecificationsKLDC-FYCLS 1200
KLDC-FYCLS 1300KLDC-FYCLS 1400
KLDC-FYCLS 1500KLDC-FYCLS 1600KLDC-FYCLS 2700
Overall Dimension(mm)1200X1200x25001300X1300X25001500x1300X25002000x1300Xx25002000X1500X25002000x1800X2500
Size of working area (mm)1100X700X20001200x800X20001400X700X20001900x800X20001900X1000X20001900X1300X2000
Rated air volume (m°/h)1300~15001600~18002000~22002500~27003400-36004500~4900
Wind speed (m/s)0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%
cleanliness levelA级A级A级A级A级A级
Noise (dB)727272727272
Illumination (Lux)>300>300>300>300>300>300
control method

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Power (KW)0.750.751.51.52.22.2


Note: Negative pressure weighing room can be made according to customer requirements for non-standard products. 

Specification

Neg Furls Negative Pressure Weighing Chambers are dedicated to providing the user with the best possible weighing environment with their superior design and high quality materials. The following are its main product features:

  • High efficiency fan system:

The fan adopts advanced technology with the advantages of long life, low noise, maintenance-free and low vibration, which ensures the stability and reliability of the equipment during operation and reduces the maintenance cost.

  • Double-layer negative pressure structure:

The equipment adopts a unique double-layer negative pressure structure design, which effectively prevents any risk of leakage and ensures the safety and reliability of the working environment.

  • Excellent Air Uniform Distribution:

The negative pressure weighing chamber has excellent air distribution performance, ensuring uniform air flow in the chamber and avoiding any dead space, thus improving the precision and consistency of weighing.

  • Adaptable to a variety of use environments:

The equipment is suitable for use in environments where the temperature ranges from 5℃ to 40℃, the relative humidity does not exceed 85% (no condensation), and it works normally under atmospheric pressure of 86KPa-106KPa. The power supply requirement is AC380V, three-phase, 50Hz, fully adapted to the needs of various industrial environments.

  • High-quality box structure:

The box body is made of SUS304# sanded stainless steel, with a thickness of 1.0MM (other thicknesses are optional), with exquisite welding technology, all angles are fully welded without dead ends, and the surface treatment is free of welding traces, which ensures that the overall structure is firm and durable, and the appearance is beautiful.

With its excellent design and high quality materials, the Neg Furls Negative Pressure Weighing Chamber provides users with a safe, accurate and efficient weighing environment, making it an ideal choice for laboratory and industrial applications.


Neg Furls negative pressure weighing chambers are always designed and manufactured with the customer's needs in mind, constantly optimizing and upgrading the performance of our products to provide users with a safe, reliable and efficient working environment. We are committed to bringing every user a superior experience through high quality materials and advanced technology.

  • Variable frequency control:

Neg Furls negative pressure weighing chambers come standard with a common control system, with an optional LCD display and operator interface available upon request. This optional system not only provides a real-time wind speed display, but also includes a programmable alarm function to ensure that abnormal conditions can be detected and dealt with in a timely manner under any circumstances, thus ensuring the safety and stability of the operating environment.

  • Lighting / Sterilization:

In order to ensure that the working environment in the weighing chamber is well lit, the Neg Furls negative pressure weighing chamber has an illumination level of more than 300 Lux at one meter from the floor, which provides a good visual environment for the operator and reduces operating errors caused by insufficient light. In addition, customers can choose to equip with germicidal lamps or ozone generators to effectively kill bacteria in the air and on surfaces to maintain a clean operating environment.

  • Sockets:

The Neg Furls negative pressure weighing chamber is equipped with waterproof and dustproof industrial sockets, the number of which can be customized according to the customer's specific needs. This high level of protection not only prevents the intrusion of water and dust, but also meets the power needs of various equipment, ensuring the stability and safety of equipment operation.

负压称量室配置图


Principle

In your capacity as the maker of the Negative Pressure Weighing Chamber, help me recreate an article about “Neg Furls Negative Pressure Weighing Chamber Product Working Principles Explained” based on the article below. And keep the word count to 400

The equipment uses a vertical unidirectional flow airflow form, the return air is first pre-filtered through a primary filter to dispose of the large dust particles in the airflow. After pretreatment, the air is then passed through the intermediate effect filter for secondary filtration, in order to play the role of fully protecting the high efficiency filter. Under the pressure provided by the centrifugal fan, it passes through the high-efficiency filter to meet the clean requirements. The operation area and the external environment form a relative negative pressure, so as to ensure that the dust in this area will not spread to the outdoors, and play a role in protecting the external environment.

This model weighing room adopts the structure of bag-in-bag-out replacement of G4 primary effect and F8 plate type intermediate effect, with the return air in the front of the operation area, and the front elevation of the personnel standing area as the mounting surface of the human-machine interface or buttons. This equipment is assembled by the work area, return air box, fan box, air box and the outer box of several large parts. The control panel is located in the front of the working area inside the equipment, and the control panel adopts light-touch LED control panel, which can control the starting and stopping of the fan, regulate the fan working condition, and adjust the wind speed needed in the working area (when the equipment is installed and used, it is necessary to regulate the working condition by the specialized personnel). There is a differential pressure meter next to it to test the resistance of the filter in the interior of the air supply box body and the exhaust air adjustment board, you can adjust the exhaust air volume of the equipment in a reasonable range (after the installation of the equipment in place, set up by professionals to test, please do not adjust without authorization)

In short, the working principle of both negative pressure weighing hood and negative pressure weighing chamber is based on negative pressure technology, by extracting the air inside the hood or the chamber to form a low-pressure environment, so as to realize the accurate weighing of goods. This type of weighing prevents items from evaporating, drifting or absorbing moisture and ensures the accuracy of the weighing results.

负压称量室原理图


Accessories

Options. 



1


Wind Speed Sensor 

风速传感器


2


Differential Pressure Sensor 

压差传感器


3


converter

微信截图_20240626191907.jpg


4


touchscreens

触摸屏


5


PLC control

PLC控制系统


6


 Polymer homogeneous membrane

 高分子均流膜



Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.