4` FYCLS Negative Pressure Weighing Hood - PLC control, touch screen, polymer equalization membrane

Reference Price:US$

Min. Order:

Short Description:

The Neg Furls Negative Pressure Weighing Chamber is designed with a vertical unidirectional airflow and a multi-stage filtration system to ensure clean air in the operating area.

  • Worktop Material:
  • sizes:
  • widths:
  • depths:
  • Front window opening height:
  • Power Adaptation:
  • noise:
  • lights:
  • exhaust volume:
  • surface air velocity:
  • production state:
  • customs code:
  • Product Certification:
  • Applicable area:

Cleanroom

4` FYCLS Negative Pressure Weighing Hood - PLC control, touch screen, polymer equalization membrane

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

4` FYCLS Negative Pressure Weighing Hood - PLC control, touch screen, polymer equalization membrane

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Detail

The Neg Furls Negative Pressure Weighing Chamber is designed with a vertical unidirectional airflow and a multi-stage filtration system to ensure clean air in the operating area. The air first passes through a primary filter to remove large particles of dust, then through an intermediate filter for further purification, and finally through a high-efficiency filter under the pressure of a centrifugal fan to achieve the required cleanliness.

The operation area and the external environment form a relative negative pressure, preventing the indoor dust from spreading to the outside and protecting the environment. The equipment is suitable for pharmaceutical, chemical and laboratory applications, providing a reliable clean solution to ensure a safe and efficient working environment.

When you choose a Neg Furls negative pressure weighing chamber, you are choosing safety, cleanliness and efficiency.



Negative Pressure Weighing Chamber SpecificationsKLDC-FYCLS 1200
KLDC-FYCLS 1300KLDC-FYCLS 1400
KLDC-FYCLS 1500KLDC-FYCLS 1600KLDC-FYCLS 2700
Overall Dimension(mm)1200X1200x25001300X1300X25001500x1300X25002000x1300Xx25002000X1500X25002000x1800X2500
Size of working area (mm)1100X700X20001200x800X20001400X700X20001900x800X20001900X1000X20001900X1300X2000
Rated air volume (m°/h)1300~15001600~18002000~22002500~27003400-36004500~4900
Wind speed (m/s)0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%
cleanliness levelA级A级A级A级A级A级
Noise (dB)727272727272
Illumination (Lux)>300>300>300>300>300>300
control method

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Power (KW)0.750.751.51.52.22.2


Note: Negative pressure weighing room can be made according to customer requirements for non-standard products. 

Specification

Neg Furls Negative Pressure Weighing Chambers ensure the best possible working environment and performance for the user with their superior design and advanced technology.

  • The negative pressure weighing chamber utilizes a liquid tank design to ensure a perfect seal. This design not only prevents external contaminants from entering the working area, but also maintains a high degree of cleanliness in the internal environment, ensuring the accuracy and safety of the weighing process.

  • The internal and external structure of the negative pressure weighing chamber is designed to be consistent and neat without dead space. This means that it is easy to clean and maintain, and users can easily clean the equipment thoroughly to avoid any accumulation of residue, thus maintaining long-term efficient operation of the equipment.

  • Our negative pressure weighing chambers are equipped with a manual inverter system that allows the user to adjust the air speed in the main working area as required. This feature ensures that the wind speed in the working area is always uniform and will not affect the weighing results due to uneven wind speed, providing users with a more stable working environment.

  • The filter differential pressure display device can monitor the operation status of each filter in real time. Users can know the working condition of the filter at any time and replace or maintain it in time to ensure that the negative pressure weighing chamber is always in the best operating condition.

  • The negative pressure weighing chamber adopts a unique air duct design, which effectively controls the working noise of the whole machine. Even during long periods of operation, the user can work in a quiet environment, improving overall working comfort.

Neg Furls negative pressure weighing chambers provide an efficient, safe and stable working environment through a series of innovative design and technology applications, making them the ideal choice for accurate weighing operations.


Neg Furls is committed to providing the highest quality negative pressure weighing chamber products. Through rigorous material selection and advanced technology, we ensure that each unit delivers the performance and reliability you need for accurate weighing operations.


  • Differential Pressure Gauge:

Neg Furls negative pressure weighing chambers are equipped with two highly accurate differential pressure gauges. These differential pressure gauges are used to monitor the pressure difference between the chamber and the outside of the chamber in real time, ensuring that a stable negative pressure environment is maintained during any operation. The differential pressure gauges allow the user to identify and adjust any factors that may affect the stability of the negative pressure, thus ensuring safe and accurate weighing operations.

  • Polymer flow-evening membrane:

In order to improve the uniformity of airflow, Neg Furls negative pressure weighing chamber adopts advanced polymer equalization membrane technology. This polymer material not only distributes the air flow evenly, reducing turbulence and dead spots, but is also resistant to corrosion, high temperatures and easy to clean. The application of polymer equalization membrane significantly improves the air circulation efficiency in the weighing room, ensuring a clean and safe operating environment.

  • Variable frequency control:

The air velocity control system in Neg Furls negative pressure weighing chambers utilizes variable frequency control technology. Normally, the system uses the normal control mode, which meets most weighing requirements. For more demanding users, an optional LCD display and operator interface is available. This advanced configuration not only displays wind speed in real time, but also has setup and alarm functions. When the wind speed is out of the set range, the system will automatically sound an alarm, prompting the user to make the necessary adjustments. This intelligent control system greatly enhances the ease of operation and safety of the negative pressure weighing chamber.



负压称量室配置图


Principle

The Neg Furls Negative Pressure Weighing Chamber is designed to provide a high cleanliness working environment to ensure the accuracy and safety of the weighing process. The system maintains negative pressure in the operating area through a series of advanced filtration and air circulation technologies, in compliance with pharmaceutical GMP standards.

The air in the room is initially purified by primary and intermediate filters. After that, the air is pressed by centrifugal fans into a static pressure box, and then passes through a high-efficiency filter for deeper purification. The air treated by the high-efficiency filter will be blown out evenly from the air outlet of the air diffusion air supply unit to form a uniform cross-section air velocity. In this way, clean air flows through the work area, ensuring a high level of cleanliness in the operating area.

To further enhance safety and accuracy, the center weighing hood of the Neg Furls Negative Pressure Weighing Chamber is maintained at negative pressure at all times. This design ensures that no contaminants escape during the weighing process, while exhausting approximately 10% of the recirculated air, increasing the stability and safety of the system.

The air in the center weighing chamber is self-circulating through a three-stage filtration system. This system includes a high-efficiency filter capable of removing 99.99% of particulate matter (≥0.3μm). This efficient dust removal ensures a clean operating environment that meets the strict GMP requirements of pharmaceutical companies.

The Neg Furls Negative Pressure Weighing Chamber provides a highly clean and safe weighing environment through multiple filtration and negative pressure design to meet the high standards required for pharmaceutical manufacturing.

负压称量室原理图


Accessories

Options. 



1


Wind Speed Sensor 

风速传感器


2


Differential Pressure Sensor 

压差传感器


3


converter

微信截图_20240626191907.jpg


4


touchscreens

触摸屏


5


PLC control

PLC控制系统


6


 Polymer homogeneous membrane

 高分子均流膜



Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5