MENU
X

Do medical devices require cleanroom manufacturing

  • Author:Jason Peng

  • Cleanroom Engineering Technology Manager of Deiiang Company.

    Product R&D Manager of GDC Inc. Cleanroom Equipment Manufacturing Company.

    Executive Director of Guangdong Cleanroom Industry Association of China.

    Engaged in R&D of related products for 15 years, with rich relevant technical experience

  • 2024-10-08  |  Visits:

The use of cleanrooms is an important technical decision in the development and production of medical devices. The classification of medical devices, production environment requirements, workshop layout and reasonable configuration of laboratory environment directly affect the safety and effectiveness of products. In this paper, we will discuss in detail whether medical devices need to be manufactured in A Clean Room from four aspects: classification of medical devices, environmental requirements of production workshops, workshop layout and laboratory environmental requirements.


I. Classification of medical devices

Medical equipment clean room2.jpg

Medical devices are divided into three categories according to their risk level. 1:

1.Class I medical devices: these devices are low risk, relatively loose regulation, usually do not need strict environmental control. 2. Class II medical devices: low risk, relatively loose regulation, usually do not need strict environmental control.

2. Class II medical devices: medium risk, need to meet certain production standards, environmental requirements have increased. 3.

3. Class III medical devices: these devices are high risk, directly related to patient safety, and need to be produced in a highly clean environment to ensure their safety and effectiveness.


II, the environmental requirements of medical device production workshop

Medical equipment clean room3.jpg

Different levels of medical devices on the production of different environmental requirements, which directly determines whether the need for clean room.

1. Class I medical device environmental requirements: Although the risk of such devices is low, but still need to control the temperature and humidity to avoid affecting product quality. The cleanliness requirements are not high, so they can be produced in a conventional industrial environment. 2.

2. Class II medical device environmental requirements: the production of such devices need to maintain the temperature at 18-26 ℃, humidity is 45-65%, cleanliness needs to reach iso 8. Although a clean room is not necessarily required, there should be obvious environmental monitoring measures to reduce the risk of microbial contamination. 3.

3. Class III medical device environmental requirements: the production of such devices must be carried out in a clean room, requiring a temperature of 22 ± 1 ℃, humidity of 45-65%, cleanliness needs to reach ISO 8. The high efficiency filtration and air circulation system of the clean room is the key to ensure product quality.


III, the layout of medical equipment production workshop requirements

Medical equipment clean room5.jpg

The layout of the production workshop directly affects the production efficiency and product safety:

1. Pedestrian flow: The pedestrian flow line in the workshop needs to be reasonably planned to avoid cross contamination. Especially in the production of high-risk Class III medical devices, special channels and areas need to be designed to ensure that the flow of personnel does not affect the clean area.

2. Logistics: The flow of raw materials and packaging materials also needs to be strictly controlled. It should be ensured that the materials are not contaminated in the process of feeding, storing, producing and discharging, especially in the clean room, the materials in and out need to be strictly sterilized and treated.

3. Process flow: the design of process flow should follow the principle of “from clean to polluted” to ensure that the cleanliness of each link in the production process is not destroyed, especially in the production of Class III medical devices, there should be a clear process specification.


IV.Laboratory environment requirements

In the stage of medical device research and development, the requirements of laboratory environment are equally important:

cleanroom_injection_molding_manufacturing.jpg

1. Aseptic room: aseptic room is the key area for sterile product testing, need to maintain the temperature at 18-26 ℃, humidity of 45-65%, cleanliness to iso 7 level, to ensure the accuracy of the test results.

2. microbiology room: used for microbial research and control of the laboratory, need to control the temperature at 18-26 ℃, humidity for 45-65%, cleanliness is also ISO 7, in order to avoid microbial impact on the results of the experiments.

3. Negative and positive control room: the environment used for control experiments needs to be well-designed to ensure the consistency and reproducibility of the experimental conditions.


To summarize, whether or not a cleanroom is required for the production of medical devices depends on their classification and risk level. Class I medical devices can be manufactured in a conventional environment, Class II medical devices need to be manufactured in a relatively clean environment, and Class III medical devices must be manufactured in a clean room to ensure product safety and effectiveness. Reasonable manufacturing environment and laboratory layout are essential to improve the quality of medical devices. Therefore, the application of clean room is an important aspect that cannot be ignored in the manufacturing process of medical devices.

Latest Hot Articles