A 6 ft Horizontal Laminar Flow Cabinet provides a sterile, particle-free work environment by directing HEPA-filtered air horizontally across the work surface.

  • Air Flow: Horizontal flow
  • Available sizes: 6 ft
  • size: 1800×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: ULPA Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

6 ft Horizontal Laminar Flow Cabinet

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

6 ft Horizontal Laminar Flow Cabinet

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 6 ft Horizontal Laminar Flow Cabinet provides a sterile, particle-free work environment by directing HEPA-filtered air horizontally across the work surface. It is ideal for applications requiring a clean workspace, such as microbiology, cell culture, and pharmaceutical preparations. The spacious 6-foot-wide cabinet allows for ample workspace, accommodating various laboratory equipment and procedures while maintaining contamination control.Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. What are the advantages of using a Horizontal Laminar Flow Cabinet in research?

A Horizontal Laminar Flow Cabinet provides a sterile environment by directing HEPA-filtered air horizontally across the work surface, preventing contamination. This is crucial in research applications involving sensitive materials, ensuring accuracy and reliability in experimental results.


2. What are the benefits of using a Horizontal Laminar Flow Cabinet?

Using a Horizontal Laminar Flow Cabinet ensures a contaminant-free work area, protecting samples and processes from airborne particulates. It enhances precision and reliability in various laboratory applications, making it an essential tool for maintaining high standards of cleanliness.


3. What is the warranty period for a Horizontal Laminar Flow Cabinet?

The warranty period for a Horizontal Laminar Flow Cabinet typically ranges from one to three years, depending on the manufacturer and model. It's important to check the specific warranty terms provided by the manufacturer.


4. How to ensure ergonomic use of a Horizontal Laminar Flow Cabinet?

To ensure ergonomic use of a Horizontal Laminar Flow Cabinet, adjust the height of the chair and work surface to maintain a comfortable posture. Use an adjustable chair with proper back support and ensure that frequently used tools are within easy reach to minimize strain.


5. Are there size options available for Horizontal Laminar Flow Cabinets?

Yes, Horizontal Laminar Flow Cabinets come in various sizes to accommodate different laboratory needs. Common sizes range from 2 feet to 6 feet in width, providing flexibility in workspace design and ensuring that the cabinet fits the specific requirements of the laboratory.


6. How to perform a visual inspection of a Horizontal Laminar Flow Cabinet?

To perform a visual inspection of a Horizontal Laminar Flow Cabinet, start by ensuring the cabinet is turned off and unplugged. Examine the exterior for any physical damage, such as dents or scratches. Open the front shield and inspect the interior surfaces for cleanliness and integrity. Check the condition of the pre-filters and HEPA filters for signs of wear or contamination. Ensure that all control switches, lights, and gauges are functioning properly.


7. What is the difference between a clean bench and a biosafety cabinet?

A clean bench provides a sterile environment by directing HEPA-filtered air over the work surface but does not protect the user from biohazards. In contrast, a biosafety cabinet offers both product and user protection by containing biohazardous materials and preventing their escape into the laboratory environment.


8. How to safely dispose of filters from a Horizontal Laminar Flow Cabinet?

To safely dispose of filters from a Horizontal Laminar Flow Cabinet, first, ensure the cabinet is turned off and unplugged. Carefully remove the filters, avoiding direct contact with the filtered surfaces. Place the filters in sealed, labeled biohazard bags and follow your institution's guidelines for hazardous waste disposal.


9. Can a Horizontal Laminar Flow Cabinet be used for cell culture?

Yes, a Horizontal Laminar Flow Cabinet can be used for cell culture. It provides a sterile, particle-free environment that is essential for maintaining the integrity of cell cultures and preventing contamination during experimental procedures.


10. How do I troubleshoot airflow issues in a Horizontal Laminar Flow Cabinet?

To troubleshoot airflow issues in a Horizontal Laminar Flow Cabinet, first check the pre-filters and HEPA filters for blockage or contamination. Ensure that the blower motor is functioning correctly and that there are no obstructions in the airflow path. If problems persist, contact a professional technician for further diagnosis.


11. What are the noise reduction features in a Horizontal Laminar Flow Cabinet?

Noise reduction features in a Horizontal Laminar Flow Cabinet include sound-dampening materials in the construction, low-noise fans, and vibration-absorbing mounts. These features help maintain a quiet working environment, enhancing user comfort and concentration.


12. How to test the HEPA filter integrity in a Horizontal Laminar Flow Cabinet?

To test the HEPA filter integrity in a Horizontal Laminar Flow Cabinet, perform a DOP (Dispersed Oil Particulate) test or a similar aerosol-based test. Introduce a challenge aerosol upstream of the filter and measure the downstream concentration to ensure the filter is effectively capturing particles.


13. What is the lifespan of a Horizontal Laminar Flow Cabinet?

The lifespan of a Horizontal Laminar Flow Cabinet typically ranges from 10 to 15 years, depending on usage, maintenance, and environmental conditions. Regular servicing and proper care can help extend the operational life of the cabinet.


14. What is the airflow pattern in a Horizontal Laminar Flow Cabinet?

In a Horizontal Laminar Flow Cabinet, air is drawn through a HEPA filter at the back of the cabinet and flows horizontally across the work surface towards the front. This laminar airflow ensures a consistent, sterile environment by sweeping away contaminants and preventing particle accumulation.


15. What are the key features to look for in a Horizontal Laminar Flow Cabinet?

Key features to look for in a Horizontal Laminar Flow Cabinet include HEPA filtration, a durable and easy-to-clean work surface, adjustable airflow controls, low noise levels, and ergonomic design. Additional features like UV sterilization and built-in electrical outlets can enhance functionality.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.