6 ft Horizontal Laminar Flow Cabinet
Reference Price:US$from $800





Cleanroom
6 ft Horizontal Laminar Flow Cabinet
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
6 ft Horizontal Laminar Flow Cabinet
Validation
Installation & Validation
Find Similar Products
-
12 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
9 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
8 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
7 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
6 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set -
5 ft Horizontal Laminar Flow Cabinet
US$from $550
Min. Order:1 Set
Product Briefing
A 6 ft Horizontal Laminar Flow Cabinet provides a sterile, particle-free work environment by directing HEPA-filtered air horizontally across the work surface. It is ideal for applications requiring a clean workspace, such as microbiology, cell culture, and pharmaceutical preparations. The spacious 6-foot-wide cabinet allows for ample workspace, accommodating various laboratory equipment and procedures while maintaining contamination control.Here’s a detailed overview of its features, functions, and benefits:
Applications
Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.
Pharmaceuticals: Used in the preparation and compounding of sterile medications.
Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.
Research: Provides a clean environment for various scientific experiments and procedures.
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Features
High-Quality Construction
| |
Quiet Operation
| |
ULPA Filter
| |
Energy-efficient
| |
GDC™ Antimicrobial Powder Coating
|
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
-
Stainless Steel Orifice Tabletop
-
ULPA Ultra GX Filter
-
UV Germicidal Lamps
-
De-static equipment
-
Support Stand with Caster Wheels
FAQ
1. What are the advantages of using a Horizontal Laminar Flow Cabinet in research?
A Horizontal Laminar Flow Cabinet provides a sterile environment by directing HEPA-filtered air horizontally across the work surface, preventing contamination. This is crucial in research applications involving sensitive materials, ensuring accuracy and reliability in experimental results.
2. What are the benefits of using a Horizontal Laminar Flow Cabinet?
Using a Horizontal Laminar Flow Cabinet ensures a contaminant-free work area, protecting samples and processes from airborne particulates. It enhances precision and reliability in various laboratory applications, making it an essential tool for maintaining high standards of cleanliness.
3. What is the warranty period for a Horizontal Laminar Flow Cabinet?
The warranty period for a Horizontal Laminar Flow Cabinet typically ranges from one to three years, depending on the manufacturer and model. It's important to check the specific warranty terms provided by the manufacturer.
4. How to ensure ergonomic use of a Horizontal Laminar Flow Cabinet?
To ensure ergonomic use of a Horizontal Laminar Flow Cabinet, adjust the height of the chair and work surface to maintain a comfortable posture. Use an adjustable chair with proper back support and ensure that frequently used tools are within easy reach to minimize strain.
5. Are there size options available for Horizontal Laminar Flow Cabinets?
Yes, Horizontal Laminar Flow Cabinets come in various sizes to accommodate different laboratory needs. Common sizes range from 2 feet to 6 feet in width, providing flexibility in workspace design and ensuring that the cabinet fits the specific requirements of the laboratory.
6. How to perform a visual inspection of a Horizontal Laminar Flow Cabinet?
To perform a visual inspection of a Horizontal Laminar Flow Cabinet, start by ensuring the cabinet is turned off and unplugged. Examine the exterior for any physical damage, such as dents or scratches. Open the front shield and inspect the interior surfaces for cleanliness and integrity. Check the condition of the pre-filters and HEPA filters for signs of wear or contamination. Ensure that all control switches, lights, and gauges are functioning properly.
7. What is the difference between a clean bench and a biosafety cabinet?
A clean bench provides a sterile environment by directing HEPA-filtered air over the work surface but does not protect the user from biohazards. In contrast, a biosafety cabinet offers both product and user protection by containing biohazardous materials and preventing their escape into the laboratory environment.
8. How to safely dispose of filters from a Horizontal Laminar Flow Cabinet?
To safely dispose of filters from a Horizontal Laminar Flow Cabinet, first, ensure the cabinet is turned off and unplugged. Carefully remove the filters, avoiding direct contact with the filtered surfaces. Place the filters in sealed, labeled biohazard bags and follow your institution's guidelines for hazardous waste disposal.
9. Can a Horizontal Laminar Flow Cabinet be used for cell culture?
Yes, a Horizontal Laminar Flow Cabinet can be used for cell culture. It provides a sterile, particle-free environment that is essential for maintaining the integrity of cell cultures and preventing contamination during experimental procedures.
10. How do I troubleshoot airflow issues in a Horizontal Laminar Flow Cabinet?
To troubleshoot airflow issues in a Horizontal Laminar Flow Cabinet, first check the pre-filters and HEPA filters for blockage or contamination. Ensure that the blower motor is functioning correctly and that there are no obstructions in the airflow path. If problems persist, contact a professional technician for further diagnosis.
11. What are the noise reduction features in a Horizontal Laminar Flow Cabinet?
Noise reduction features in a Horizontal Laminar Flow Cabinet include sound-dampening materials in the construction, low-noise fans, and vibration-absorbing mounts. These features help maintain a quiet working environment, enhancing user comfort and concentration.
12. How to test the HEPA filter integrity in a Horizontal Laminar Flow Cabinet?
To test the HEPA filter integrity in a Horizontal Laminar Flow Cabinet, perform a DOP (Dispersed Oil Particulate) test or a similar aerosol-based test. Introduce a challenge aerosol upstream of the filter and measure the downstream concentration to ensure the filter is effectively capturing particles.
13. What is the lifespan of a Horizontal Laminar Flow Cabinet?
The lifespan of a Horizontal Laminar Flow Cabinet typically ranges from 10 to 15 years, depending on usage, maintenance, and environmental conditions. Regular servicing and proper care can help extend the operational life of the cabinet.
14. What is the airflow pattern in a Horizontal Laminar Flow Cabinet?
In a Horizontal Laminar Flow Cabinet, air is drawn through a HEPA filter at the back of the cabinet and flows horizontally across the work surface towards the front. This laminar airflow ensures a consistent, sterile environment by sweeping away contaminants and preventing particle accumulation.
15. What are the key features to look for in a Horizontal Laminar Flow Cabinet?
Key features to look for in a Horizontal Laminar Flow Cabinet include HEPA filtration, a durable and easy-to-clean work surface, adjustable airflow controls, low noise levels, and ergonomic design. Additional features like UV sterilization and built-in electrical outlets can enhance functionality.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set