3 ft Medical Clean bench
Reference Price:US$from $1500




Cleanroom
3 ft Medical Clean bench
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
3 ft Medical Clean bench
Validation
Installation & Validation
Find Similar Products
-
3 ft Medical Clean bench
US$
Min. Order:1 Set -
4 ft Medical Clean bench-Horizontal Flow
US$
Min. Order:1 Set -
6 ft Medical Clean bench
US$
Min. Order:1 Set -
7 ft Medical Clean bench-Single side, Ho
US$
Min. Order:1 Set -
8 ft Medical Clean bench- Horizontal Flo
US$
Min. Order:1 Set -
5 ft Medical Clean bench-Single side, Ho
US$
Min. Order:1 Set
Product Briefing
A 3 ft medical clean bench is a compact, laboratory device designed to provide a sterile, particle-free environment for various medical and research tasks. It features a HEPA filter system that directs clean air over the work surface, ensuring contamination-free operations. Ideal for small labs or limited spaces, it supports critical applications requiring high-level cleanliness. Here’s a detailed overview of its features, functions, and benefits:
Applications
Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.
Pharmaceuticals: Used in the preparation and compounding of sterile medications.
Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.
Research: Provides a clean environment for various scientific experiments and procedures.
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Features
High-Quality Construction
| |
Quiet Operation
| |
ULPA Filter
| |
Energy-efficient
| |
GDC™ Antimicrobial Powder Coating
|
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
Stainless Steel Orifice Tabletop
ULPA Ultra GX Filter
UV Germicidal Lamps
De-static equipment
Support Stand with Caster Wheels
FAQ
1. How to handle spills in a clean bench?
To handle spills in a clean bench, first, stop all work and immediately notify personnel in the area. Use absorbent materials to contain the spill and clean the surface with an appropriate disinfectant. Dispose of contaminated materials in biohazard bags and ensure the bench is decontaminated before resuming work.
2. How to perform routine inspections on a clean bench?
Performing routine inspections on a clean bench involves checking the HEPA filter for integrity, ensuring consistent airflow, and verifying that all controls and indicators are functioning correctly. Document any findings and address issues promptly to maintain optimal performance and safety.
3. How to monitor the performance of a clean bench?
Monitoring the performance of a clean bench includes regular airflow testing, checking HEPA filter efficiency, and ensuring proper operation of all controls. Use particle counters to measure air quality and document results to track performance over time. Regular calibration of monitoring equipment is also essential.
4. What is the cost of a medical clean bench?
The cost of a medical clean bench varies depending on size, features, and brand. Typically, prices range from $3,000 to $10,000. Additional costs may include installation, maintenance, and filter replacements.
5. What is the energy consumption of a medical clean bench?
The energy consumption of a medical clean bench generally ranges from 100 to 400 watts. The exact consumption depends on the model and any additional features such as lighting and ventilation systems.
6. What are common contaminants in a clean bench?
Common contaminants in a clean bench include dust particles, microorganisms, and chemical residues. These can originate from the environment, materials, or personnel working within the bench.
7. How to prevent cross-contamination in a clean bench?
To prevent cross-contamination in a clean bench, always work with clean, sterilized materials and tools. Arrange items to minimize disruption of airflow and follow strict protocols for handling samples and reagents. Regular cleaning and proper use of PPE also play crucial roles.
8. What safety precautions should be taken with a medical clean bench?
Safety precautions for using a medical clean bench include wearing appropriate PPE, such as gloves and lab coats, and following proper decontamination procedures. Ensure the bench is correctly grounded and regularly inspect it for any mechanical issues. Always follow the manufacturer's guidelines and standard operating procedures.
9. How to optimize work practices in a clean bench?
Optimizing work practices in a clean bench involves organizing the workspace efficiently, minimizing movement to reduce particle generation, and keeping essential tools within reach. Regularly clean the work area and adhere to protocols to maintain a sterile environment.
10. How to ensure laminar flow in a clean bench?
To ensure laminar flow in a clean bench, keep the work surface clear of obstructions and avoid rapid movements that can disrupt the airflow. Regularly check and maintain the HEPA filters and ensure the bench is operating at the correct airflow settings.
11. What is the ideal temperature for operating a clean bench?
The ideal temperature for operating a clean bench is typically between 20°C to 25°C (68°F to 77°F). Maintaining this temperature range helps ensure optimal performance and comfort for the operator.
12. How does a horizontal flow clean bench work?
A horizontal flow clean bench works by drawing air through a HEPA filter located at the back of the unit. The filtered air is then directed horizontally across the work surface, sweeping contaminants away from the working area and towards the user, ensuring a clean and sterile environment.
13. How to prevent airflow blockage in a clean bench?
To prevent airflow blockage in a clean bench, avoid placing large items near the back of the unit where air enters. Arrange materials to allow free circulation of air and regularly inspect the HEPA filter for any obstructions or damage.
14. What is a medical clean bench?
A medical clean bench is a laboratory device designed to provide a sterile, particle-free environment for medical and research tasks. It uses HEPA-filtered air to create a contamination-free area, ensuring the cleanliness required for sensitive procedures.
15. How to balance airflow in a clean bench?
Balancing airflow in a clean bench involves adjusting the fan speed and ensuring the HEPA filters are clean and functioning correctly. Regularly monitor the airflow pattern using anemometers or smoke tests to verify uniform laminar flow across the work surface.
16. How to conduct a risk assessment for using a clean bench?
Conducting a risk assessment for using a clean bench involves identifying potential hazards, evaluating the likelihood and severity of risks, and implementing control measures to mitigate them. Consider factors such as material handling, airflow integrity, and operator training.
17. How to perform a certification audit for a clean bench?
Performing a certification audit for a clean bench involves checking the unit's compliance with industry standards, such as airflow velocity, HEPA filter integrity, and overall cleanliness. Use calibrated instruments to measure performance and document findings for regulatory purposes.
18. What is the airflow pattern in a horizontal flow clean bench?
In a horizontal flow clean bench, the airflow pattern involves air being drawn through a HEPA filter at the back of the unit and then moving horizontally across the work surface toward the user. This ensures a continuous flow of clean air, sweeping contaminants away from the working area.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set