MENU
X

7 ft Medical Clean bench-Single side, Horizontal Flow

Reference Price:US$from $1500

Short Description:

A 7 ft medical clean bench is a specialized laboratory device designed to provide a larger sterile, particle-free workspace ideal for medical, pharmaceutical, and research applications.

  • Air Flow: Horizontal flow
  • Available sizes: 7 ft
  • size: 2100×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: ULPA Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

7 ft Medical Clean bench-Single side, Horizontal Flow

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

7 ft Medical Clean bench-Single side, Horizontal Flow

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 7 ft medical clean bench is a specialized laboratory device designed to provide a larger sterile, particle-free workspace ideal for medical, pharmaceutical, and research applications. It utilizes a HEPA filter to generate laminar airflow across a seven-foot area, ensuring contamination-free operations, accommodating more extensive experiments, and multiple tasks while maintaining high levels of cleanliness and safety. Here’s a detailed overview of its features, functions, and benefits:

Horizontal Laminar Flow Cabinet.jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. How to manage inventory of clean bench supplies?

To manage inventory of clean bench supplies effectively, keep an up-to-date list of all items and their stock levels. Regularly audit the inventory to ensure supplies are sufficient and reorder before running out. Implement a tracking system to monitor usage patterns and predict future needs.


2. How to plan for clean bench replacement?

Planning for clean bench replacement involves assessing the current bench's performance and determining its lifespan. Consider factors such as wear and tear, frequency of use, and technological advancements. Budget for replacement costs and schedule a suitable time for installation to minimize disruptions.


3. What are the maintenance steps for a horizontal flow clean bench?

Routine maintenance of a horizontal flow clean bench includes regular cleaning of the work surface and surrounding area, inspection and replacement of HEPA filters, and checking for any airflow obstructions. Perform airflow velocity tests periodically to ensure consistent performance.


4. How to ensure compliance with clean bench regulations?

To ensure compliance with clean bench regulations, stay updated on current standards and guidelines from relevant authorities. Implement standard operating procedures (SOPs) that adhere to these regulations and conduct regular audits. Provide training to operators and maintain detailed documentation of all activities.


5. How to achieve uniform airflow in a clean bench?

Achieving uniform airflow in a clean bench requires regular testing and balancing of the airflow. Ensure there are no obstructions on the work surface and that HEPA filters are clean and properly installed. Adjust the fan speed if necessary and conduct periodic airflow mapping to detect and correct any inconsistencies.


6. How to optimize work practices in a clean bench?

Optimizing work practices in a clean bench involves organizing tools and materials efficiently, minimizing unnecessary movements, and following strict protocols. Keep frequently used items within easy reach and reduce rapid hand motions to maintain airflow. Regularly clean the work surface and tools.


7. How does a clean bench differ from a laminar flow hood?

A clean bench provides a sterile, particle-free environment by directing HEPA-filtered air over the work surface, primarily protecting the product. In contrast, a laminar flow hood is designed to protect both the product and the operator by ensuring unidirectional airflow and may include additional features for handling hazardous materials.


8. How to conduct a risk assessment for using a clean bench?

Conducting a risk assessment for a clean bench involves identifying potential hazards and evaluating their likelihood and impact. Consider factors such as material handling, operator training, and environmental conditions. Implement control measures to mitigate identified risks and ensure safe operation.


9. How to test the effectiveness of a clean bench?

To test the effectiveness of a clean bench, conduct particle count assessments and airflow velocity measurements. Perform HEPA filter integrity tests to ensure they are functioning correctly. Regularly document and review these tests to maintain optimal performance and compliance with standards.


10. What types of filters are used in a medical clean bench?

Medical clean benches typically use HEPA filters, which are highly efficient in capturing particles as small as 0.3 microns. In some cases, ULPA filters may be used for even higher levels of filtration efficiency, capturing particles as small as 0.12 microns.


11. What is the impact of room conditions on clean bench performance?

Room conditions such as temperature, humidity, and air quality can significantly impact the performance of a clean bench. Variations in temperature and humidity can affect the airflow and filter efficiency, while high levels of dust or contaminants in the room can compromise the clean bench's ability to maintain a sterile environment.


12. How to select a clean bench for a specific application?

Selecting a clean bench for a specific application involves considering the size of the workspace needed, the level of cleanliness required, and the types of materials to be handled. Evaluate the airflow design (horizontal or vertical) and ensure compatibility with existing laboratory equipment and protocols.


13. How to select the right filter for a clean bench?

Selecting the right filter for a clean bench involves considering the type of contaminants that need to be removed and the required level of air cleanliness. HEPA filters are commonly used for their high efficiency in capturing particles as small as 0.3 microns. Consult the manufacturer's guidelines to ensure compatibility and optimal performance.


14. How to balance airflow in a clean bench?

Balancing airflow in a clean bench involves adjusting the fan speed and ensuring that the HEPA filter is properly seated and not obstructed. Perform airflow velocity tests at different points across the work surface to check for uniformity. Make necessary adjustments to achieve consistent and even airflow throughout the bench.


15. What is the energy consumption of a medical clean bench?

The energy consumption of a medical clean bench typically ranges from 100 to 400 watts, depending on the model and additional features like lighting and ventilation systems. It's crucial to consider the bench's energy efficiency to ensure cost-effective and sustainable operation.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.