6` FYCLS Negative Pressure Raw Material Dispensing Room - Wind Speed Sensor, Wind Pressure Sensor, Frequency Converter
Reference Price:US$
Min. Order:Cleanroom
6` FYCLS Negative Pressure Raw Material Dispensing Room - Wind Speed Sensor, Wind Pressure Sensor, Frequency Converter
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
6` FYCLS Negative Pressure Raw Material Dispensing Room - Wind Speed Sensor, Wind Pressure Sensor, Frequency Converter
Validation
Installation & Validation
Find Similar Products
-
1` FYCLS Negative Pressure Raw Material
US$
Min. Order: -
2` FYCLS Negative Pressure Raw Material
US$
Min. Order: -
3` FYCLS Negative Pressure Raw Material
US$
Min. Order: -
4` FYCLS Negative Pressure Raw Material
US$
Min. Order: -
5` FYCLS Negative Pressure Raw Material
US$
Min. Order: -
6` FYCLS Negative Pressure Raw Material
US$
Min. Order:
Detail
Negative pressure weighing room is a kind of local purification equipment used in specific fields, such as pharmaceuticals, microbiology research and scientific experiments, whose core function is to form a negative-pressure environment in a closed space to prevent pollutants from leaking and to ensure the cleanliness and safety of the operation process. It is mainly composed of working area, return air box, fan box, air outlet box and outer box. These parts work together to form a complete purification system.
Negative Pressure Weighing Chamber Specifications | KLDC-FYCLS 1200 | KLDC-FYCLS 1300 | KLDC-FYCLS 1400 | KLDC-FYCLS 1500 | KLDC-FYCLS 1600 | KLDC-FYCLS 2700 |
---|---|---|---|---|---|---|
Overall Dimension(mm) | 1200X1200x2500 | 1300X1300X2500 | 1500x1300X2500 | 2000x1300Xx2500 | 2000X1500X2500 | 2000x1800X2500 |
Size of working area (mm) | 1100X700X2000 | 1200x800X2000 | 1400X700X2000 | 1900x800X2000 | 1900X1000X2000 | 1900X1300X2000 |
Rated air volume (m°/h) | 1300~1500 | 1600~1800 | 2000~2200 | 2500~2700 | 3400-3600 | 4500~4900 |
Wind speed (m/s) | 0.45+20% | 0.45+20% | 0.45+20% | 0.45+20% | 0.45+20% | 0.45+20% |
cleanliness level | A级 | A级 | A级 | A级 | A级 | A级 |
Noise (dB) | 72 | 72 | 72 | 72 | 72 | 72 |
Illumination (Lux) | >300 | >300 | >300 | >300 | >300 | >300 |
control method | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control | Inverter Control LCD control |
Power (KW) | 0.75 | 0.75 | 1.5 | 1.5 | 2.2 | 2.2 |
Note: Negative pressure weighing room can be made according to customer requirements for non-standard products.
Specification
Long Life Fans and Low Noise Design
The long-life fan design of Neg Furls negative pressure weighing chambers ensures long-lasting durability, reduces maintenance frequency and lowers operating costs. At the same time, the low-noise design provides users with a quieter working environment and avoids unwanted noise disturbances.
Double-layer negative pressure structure
The double-layer structure of this negative pressure weighing chamber effectively prevents the risk of possible leakage and ensures the stability and safety of the weighing environment.
Excellent air distribution
The well-designed air flow path of the Neg Furls negative pressure weighing chamber achieves uniform air distribution and ensures a continuous supply of clean air in the work area.
Automatic Constant or Stepwise Adjustment of Air Velocity
The air velocity can be adjusted according to the actual needs by means of an automatic constant or stepwise adjustment function, in order to adapt to different weighing requirements.
Liquid tank design ensures perfect sealing
The liquid tank design in Neg Furls negative pressure weighing chambers prevents spillage of liquid or solid reagents and ensures an airtight weighing environment.
Consistency inside and out, no dead space
The simple design of the internal structure of the equipment, with no unnecessary dead space, makes it easy to clean and maintain, and also ensures the cleanliness of the weighing environment.
Manual frequency conversion system for wind speed
The manual frequency conversion system allows the operator to manually adjust the wind speed according to the actual situation in order to achieve the best weighing effect.
Filter Differential Pressure Indicator
The filter differential pressure display device monitors the operating condition of the filter in real time, ensuring real-time monitoring and maintenance of the weighing environment.
Unique air duct design
Neg Furls negative pressure weighing chambers have a unique air duct design that effectively controls noise during operation and provides a quiet weighing environment.
Main working area with equalized flow design
The main working area of the machine is designed with equalized flow, which can effectively control the spillage and uplift of dust and reagents to protect the operator and the environment.
Chamber Material
Neg Furls Negative Pressure Weighing Chambers are constructed from high quality SUS304 stainless steel, a material with excellent corrosion resistance and durability that can withstand a wide range of laboratory environments and ensure long term stability. The chambers are precision bent, welded and assembled to ensure a sturdy and level structure for easy cleaning and maintenance.
Polymer homogenizing membrane
Neg Furls Negative Pressure Weighing Chambers are equipped with a polymer equalization membrane that effectively improves the uniformity of the airflow, ensures consistent air velocity in the working area, and provides stable environmental conditions for experiments. The design of the membrane helps to distribute the air evenly and avoid turbulence, thus protecting the accuracy of the experimental process.
Filtration Systems
The Neg Furls Negative Pressure Weighing Chamber utilizes a two-stage filtration system consisting of a primary filter and a high-efficiency filter to meet DOP or PAO testing requirements. The design of the filtration system balances filtration efficiency with ease of replacement, making it easy to remove and replace the filter from the front or the top, ensuring ease of operation and safety.
Differential Pressure Gauge
The Differential Pressure Gauge is an integral part of the Neg Furls Negative Pressure Weighing Chamber. It monitors the resistance of the filters in real time and provides the operator with accurate differential pressure information to help determine if the filters need to be replaced and to ensure the continuous and efficient operation of the weighing chamber.
Frequency Control
The Neg Furls Negative Pressure Weighing Chamber supports variable frequency control, which allows the operator to adjust and monitor the air speed through the LCD display, realizing precise control of the air speed in the working area. This feature is essential to ensure the stability of the lab environment.
Lighting and Sterilization
The Neg Furls Negative Pressure Weighing Chamber is well illuminated with more than 300 Lux, ensuring that the operator is able to carry out weighing operations in a bright environment. Sterilization options, such as UV germicidal lamps or ozone generators, eliminate airborne microorganisms and provide a cleaner environment for experiments.
Weighing Stands and Sockets
The Neg Furls Negative Pressure Weighing Chamber is equipped with a weighing table for weighing utensils and waterproof and dustproof industrial sockets to provide a safe power supply for different types of equipment.
Principle
Negative pressure weighing room adopts vertical unidirectional flow airflow form, the air is first pre-filtered through the primary filter to remove larger particles of dust particles, and then through the intermediate filter for secondary filtration, and finally under the pressure of the centrifugal fan, most of the air is blown vertically through the high-efficiency filter to the working area, and a small portion of the air is discharged through the external high-efficiency filters to the indoor, so as to form a negative pressure in the working area. This ensures the cleanliness of the operating environment.
Accessories
Options.
1 | Wind Speed Sensor | ![]() |
2 | Differential Pressure Sensor | |
3 | converter | |
4 | touchscreens | |
5 | PLC control | ![]() |
6 | Polymer homogeneous membrane |
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order: -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order: -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order: -
Clean bench
US$600-2000 USD/Unit
Min. Order: -
Air Filter
US$3-50 USD/Unit
Min. Order: -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order: -
Pass Box
US$200-500 USD/Unit
Min. Order: -
FFU
US$135-350 USD/Unit
Min. Order: -
Fume Hood
US$700-1500 USD/Unit
Min. Order: -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order: -
Clean room floor
US$5-20 USD/Sq.
Min. Order: -
Clean room ceiling
US$
Min. Order: