MENU
X

6` FYCLS Negative Pressure Raw Material Dispensing Room - Wind Speed Sensor, Wind Pressure Sensor, Frequency Converter

Reference Price:US$

Min. Order:

Short Description:

Negative pressure weighing room is a kind of local purification equipment used in specific fields, such as pharmaceuticals, microbiology research and scientific experiments, whose core function is to form a negative-pressure environment in a closed space to prevent pollutants from leaking and to ensure the cleanliness and safety of the operation process.

  • Worktop Material:
  • sizes:
  • widths:
  • depths:
  • Front window opening height:
  • Power Adaptation:
  • noise:
  • lights:
  • exhaust volume:
  • surface air velocity:
  • production state:
  • customs code:
  • Product Certification:
  • Applicable area:

Cleanroom

6` FYCLS Negative Pressure Raw Material Dispensing Room - Wind Speed Sensor, Wind Pressure Sensor, Frequency Converter

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

6` FYCLS Negative Pressure Raw Material Dispensing Room - Wind Speed Sensor, Wind Pressure Sensor, Frequency Converter

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Detail

Negative pressure weighing room is a kind of local purification equipment used in specific fields, such as pharmaceuticals, microbiology research and scientific experiments, whose core function is to form a negative-pressure environment in a closed space to prevent pollutants from leaking and to ensure the cleanliness and safety of the operation process. It is mainly composed of working area, return air box, fan box, air outlet box and outer box. These parts work together to form a complete purification system.

Negative Pressure Weighing Chamber SpecificationsKLDC-FYCLS 1200
KLDC-FYCLS 1300KLDC-FYCLS 1400
KLDC-FYCLS 1500KLDC-FYCLS 1600KLDC-FYCLS 2700
Overall Dimension(mm)1200X1200x25001300X1300X25001500x1300X25002000x1300Xx25002000X1500X25002000x1800X2500
Size of working area (mm)1100X700X20001200x800X20001400X700X20001900x800X20001900X1000X20001900X1300X2000
Rated air volume (m°/h)1300~15001600~18002000~22002500~27003400-36004500~4900
Wind speed (m/s)0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%0.45+20%
cleanliness levelA级A级A级A级A级A级
Noise (dB)727272727272
Illumination (Lux)>300>300>300>300>300>300
control method

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Inverter Control

LCD control

Power (KW)0.750.751.51.52.22.2


Note: Negative pressure weighing room can be made according to customer requirements for non-standard products. 

Specification

  • Long Life Fans and Low Noise Design

The long-life fan design of Neg Furls negative pressure weighing chambers ensures long-lasting durability, reduces maintenance frequency and lowers operating costs. At the same time, the low-noise design provides users with a quieter working environment and avoids unwanted noise disturbances.


  • Double-layer negative pressure structure

The double-layer structure of this negative pressure weighing chamber effectively prevents the risk of possible leakage and ensures the stability and safety of the weighing environment.


  • Excellent air distribution

The well-designed air flow path of the Neg Furls negative pressure weighing chamber achieves uniform air distribution and ensures a continuous supply of clean air in the work area.

  • Automatic Constant or Stepwise Adjustment of Air Velocity

The air velocity can be adjusted according to the actual needs by means of an automatic constant or stepwise adjustment function, in order to adapt to different weighing requirements.

  • Liquid tank design ensures perfect sealing

The liquid tank design in Neg Furls negative pressure weighing chambers prevents spillage of liquid or solid reagents and ensures an airtight weighing environment.

  • Consistency inside and out, no dead space

The simple design of the internal structure of the equipment, with no unnecessary dead space, makes it easy to clean and maintain, and also ensures the cleanliness of the weighing environment.

  • Manual frequency conversion system for wind speed

The manual frequency conversion system allows the operator to manually adjust the wind speed according to the actual situation in order to achieve the best weighing effect.

Filter Differential Pressure Indicator

The filter differential pressure display device monitors the operating condition of the filter in real time, ensuring real-time monitoring and maintenance of the weighing environment.

  • Unique air duct design

Neg Furls negative pressure weighing chambers have a unique air duct design that effectively controls noise during operation and provides a quiet weighing environment.

Main working area with equalized flow design

The main working area of the machine is designed with equalized flow, which can effectively control the spillage and uplift of dust and reagents to protect the operator and the environment.


  • Chamber Material

Neg Furls Negative Pressure Weighing Chambers are constructed from high quality SUS304 stainless steel, a material with excellent corrosion resistance and durability that can withstand a wide range of laboratory environments and ensure long term stability. The chambers are precision bent, welded and assembled to ensure a sturdy and level structure for easy cleaning and maintenance.

  • Polymer homogenizing membrane

Neg Furls Negative Pressure Weighing Chambers are equipped with a polymer equalization membrane that effectively improves the uniformity of the airflow, ensures consistent air velocity in the working area, and provides stable environmental conditions for experiments. The design of the membrane helps to distribute the air evenly and avoid turbulence, thus protecting the accuracy of the experimental process.

  • Filtration Systems

The Neg Furls Negative Pressure Weighing Chamber utilizes a two-stage filtration system consisting of a primary filter and a high-efficiency filter to meet DOP or PAO testing requirements. The design of the filtration system balances filtration efficiency with ease of replacement, making it easy to remove and replace the filter from the front or the top, ensuring ease of operation and safety.

  • Differential Pressure Gauge

The Differential Pressure Gauge is an integral part of the Neg Furls Negative Pressure Weighing Chamber. It monitors the resistance of the filters in real time and provides the operator with accurate differential pressure information to help determine if the filters need to be replaced and to ensure the continuous and efficient operation of the weighing chamber.

  • Frequency Control

The Neg Furls Negative Pressure Weighing Chamber supports variable frequency control, which allows the operator to adjust and monitor the air speed through the LCD display, realizing precise control of the air speed in the working area. This feature is essential to ensure the stability of the lab environment.

  • Lighting and Sterilization

The Neg Furls Negative Pressure Weighing Chamber is well illuminated with more than 300 Lux, ensuring that the operator is able to carry out weighing operations in a bright environment. Sterilization options, such as UV germicidal lamps or ozone generators, eliminate airborne microorganisms and provide a cleaner environment for experiments.

  • Weighing Stands and Sockets

The Neg Furls Negative Pressure Weighing Chamber is equipped with a weighing table for weighing utensils and waterproof and dustproof industrial sockets to provide a safe power supply for different types of equipment.

负压称量室配置图


Principle

Negative pressure weighing room adopts vertical unidirectional flow airflow form, the air is first pre-filtered through the primary filter to remove larger particles of dust particles, and then through the intermediate filter for secondary filtration, and finally under the pressure of the centrifugal fan, most of the air is blown vertically through the high-efficiency filter to the working area, and a small portion of the air is discharged through the external high-efficiency filters to the indoor, so as to form a negative pressure in the working area. This ensures the cleanliness of the operating environment.

负压称量室原理图


Accessories

Options. 



1


Wind Speed Sensor 

风速传感器


2


Differential Pressure Sensor 

压差传感器


3


converter

微信截图_20240626191907.jpg


4


touchscreens

触摸屏


5


PLC control

PLC控制系统


6


 Polymer homogeneous membrane

 高分子均流膜



Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE