8 ft Vertical Laminar Flow Cabinet
Reference Price:US$from $2000





Cleanroom
8 ft Vertical Laminar Flow Cabinet
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
8 ft Vertical Laminar Flow Cabinet
Validation
Installation & Validation
Find Similar Products
-
7 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
5 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
4 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
3 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
9 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
8 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set
Product Briefing
An 8 ft Vertical Laminar Flow Cabinet provides an expansive, sterile work area by channeling HEPA-filtered air in a vertical laminar flow pattern, ensuring a particle-free environment. It features a robust stainless steel construction, clear side panels for optimal visibility, and adjustable airflow controls. This cabinet is ideal for large-scale applications in industries such as pharmaceuticals, biotechnology, and electronics, where contamination control is critical.
Applications
Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.
Pharmaceuticals: Used in the preparation and compounding of sterile medications.
Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.
Research: Provides a clean environment for various scientific experiments and procedures.
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Supply PowerAC 1N 220V/50HzControl System4.3"touch screen,3 stage regulation,light,sterilization
Features
High-Quality Construction
| |
Quiet Operation
| |
ULPA Filter
| |
Energy-efficient
| |
GDC™ Antimicrobial Powder Coating
|
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
Stainless Steel Orifice Tabletop
ULPA Ultra GX Filter
UV Germicidal Lamps
De-static equipment
Support Stand with Caster Wheels
FAQ
1. How to enhance the filtration efficiency of a vertical laminar flow cabinet?
Enhancing the filtration efficiency of a vertical laminar flow cabinet involves regularly replacing the HEPA or ULPA filters according to the manufacturer's specifications. Keeping the pre-filters clean can reduce the load on the main filters, thereby extending their life and maintaining optimal performance. Regularly checking for and sealing any leaks in the cabinet can also help maintain high filtration efficiency.
2. How to measure the effectiveness of a vertical laminar flow cabinet?
To measure the effectiveness of a vertical laminar flow cabinet, conduct airflow velocity tests using an anemometer to ensure the airflow is within the manufacturer's specified range. Perform particle count tests to confirm that the air cleanliness meets the required standards. Document and analyze these results regularly to maintain the cabinet's performance.
3. What are the benefits of using a vertical laminar flow cabinet?
Vertical laminar flow cabinets offer several benefits, including providing a sterile and particle-free work environment, which is essential for sensitive processes. They protect both the product and the user by minimizing contamination risks. These cabinets are also versatile and can be used in various industries such as pharmaceuticals, biotechnology, and electronics.
4. What is the cost of a vertical flow cleanbench?
The cost of a vertical flow cleanbench can vary widely depending on the size, features, and manufacturer. Prices typically range from $2,000 to $10,000 or more. Custom features, higher-grade materials, and additional functionalities can increase the overall cost.
5. How to ensure consistent performance of a vertical laminar flow cabinet?
Ensure consistent performance of a vertical laminar flow cabinet by conducting regular maintenance, including filter replacements and airflow testing. Keep the work area clean and free from obstructions that could disrupt airflow. Periodically inspect and calibrate the cabinet to maintain optimal conditions for sterile operations.
6. How to upgrade an existing vertical laminar flow cabinet?
Upgrading an existing vertical laminar flow cabinet can involve installing higher efficiency filters, such as ULPA filters, upgrading to more advanced airflow control systems, or adding additional features like UV sterilization lights. Consult with the manufacturer for compatible upgrades and proper installation procedures.
7. What are the maintenance schedules for vertical flow cleanbenches?
Maintenance schedules for vertical flow cleanbenches typically include monthly inspections of airflow and filter condition, quarterly pre-filter replacements or cleanings, and annual HEPA or ULPA filter replacements. Regular cleaning of the cabinet surfaces and calibration checks should also be part of the routine maintenance.
8. What is the difference between vertical and horizontal laminar flow cabinets?
The main difference between vertical and horizontal laminar flow cabinets lies in the direction of airflow. Vertical laminar flow cabinets direct HEPA-filtered air downwards from the top, while horizontal laminar flow cabinets direct air horizontally from the back towards the front. Vertical cabinets are typically better at maintaining sterility over larger workspaces, whereas horizontal cabinets are usually more compact and easier to install in smaller labs.
9. How to maintain a vertical laminar flow cabinet?
Maintain a vertical laminar flow cabinet by regularly cleaning the surfaces with appropriate disinfectants, replacing pre-filters and HEPA or ULPA filters as needed, and conducting routine airflow and particle count tests. Ensure the cabinet is free from obstructions and perform periodic inspections to identify and address any potential issues promptly.
10. What are the potential risks associated with vertical laminar flow cabinets?
Potential risks associated with vertical laminar flow cabinets include contamination if filters are not properly maintained, possible exposure to harmful substances if the cabinet is not used correctly, and ergonomic issues due to improper workstation setup. Regular maintenance and proper training can mitigate these risks.
11. What are the guidelines for working with sensitive materials in a vertical flow cleanbench?
When working with sensitive materials in a vertical flow cleanbench, follow strict aseptic techniques, including proper gowning and gloving. Ensure the work area is organized and free from unnecessary items to avoid contamination. Regularly disinfect surfaces and avoid rapid movements that could disrupt the airflow and compromise the sterile environment.
12. What are the dimensions of a typical vertical laminar flow cabinet?
The dimensions of a typical vertical laminar flow cabinet can vary, but standard sizes usually range from 3 feet to 8 feet in width. The height is generally around 6 to 7 feet, and the depth is typically between 2 and 3 feet, providing ample workspace while maintaining a compact footprint suitable for laboratory environments.
13. What is the noise level of a vertical laminar flow cabinet?
The noise level of a vertical laminar flow cabinet typically ranges from 50 to 65 decibels, depending on the model and fan speed settings. This noise level is comparable to a normal conversation, ensuring a relatively quiet working environment conducive to concentration and focus.
14. What are the airflow specifications for a vertical laminar flow cabinet?
Airflow specifications for a vertical laminar flow cabinet generally include a laminar flow speed of 0.3 to 0.5 meters per second (60 to 100 feet per minute). The cabinet should achieve ISO 5 air cleanliness standards, ensuring a highly controlled environment with minimal particulate contamination.
15. Can a vertical laminar flow cabinet be used for pharmaceutical manufacturing?
Yes, a vertical laminar flow cabinet can be used for pharmaceutical manufacturing. These cabinets provide a sterile environment by filtering out contaminants, which is critical for maintaining the purity and safety of pharmaceutical products. Compliance with industry standards and regular validation are essential for such applications.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set