4 ft Vertical Laminar Flow Cabinet
Reference Price:US$from $1000





Cleanroom
4 ft Vertical Laminar Flow Cabinet
Choose your installation & validation options below
Quantity:
Choose your upgrade options
Quantity:
Summary
4 ft Vertical Laminar Flow Cabinet
Validation
Installation & Validation
Find Similar Products
-
7 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
5 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
4 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
3 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
9 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set -
8 ft Vertical Laminar Flow Cabinet
US$from $350
Min. Order:1 Set
Product Briefing
The 4 ft Vertical Laminar Flow Cabinet is designed to provide a sterile and contamination-free workspace by directing HEPA-filtered air vertically over the work surface. Ideal for laboratories and cleanrooms, this cabinet ensures a high level of protection for both samples and processes, featuring user-friendly controls and robust construction for reliable performance.
Applications
Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.
Pharmaceuticals: Used in the preparation and compounding of sterile medications.
Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.
Research: Provides a clean environment for various scientific experiments and procedures.
Models
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Vertical Laminar Flow Clean Bench | |||
Model | GDC-SPT-01 | GDC-SPT-02 | GDC-SPT-03 |
3 ft | 4ft | 5ft | |
External size W×D×H(mm) | 1000×850×1500 | 1200×850×1500 | 1500×850×1500 |
Internal Size W×D×H(mm) | 960×600×600 | 1160×600×600 | 1460×600×600 |
HEPA Filter(mm) | 905×585×69×1 Pcs | 1105×585×69×1 Pcs | 1405×585×69×1 Pcs |
HEPA Filter Efficiency | 99.95%@0.3μm | 99.95%@0.3μm | 99.95%@0.3μm |
G4 Pre Filter(mm) | 500×375×21×1 Pcs | 500×375×21×1 Pcs | 745×375×21×1 Pcs |
Noise | 52~62dB(A) | 52~62dB(A) | 52~62dB(A) |
Fan Pressure | 260pa | 260pa | 260pa |
Fan Power (W) | 200W×1 Pcs | 200W×1 Pcs | 200W×1 Pcs |
LED Lamp Power(W) | 12W×1 Pcs | 18W×1 Pcs | 30W×1 Pcs |
Air Velocity(m/s) | 0.45m/s±20% | ||
Clean Level | ISO 5 | ||
Supply Power | AC 1N 220V/50Hz | ||
Control System | 4.3"touch screen,3 stage regulation,light,sterilization |
Features
High-Quality Construction
| |
Quiet Operation
| |
ULPA Filter
| |
Energy-efficient
| |
GDC™ Antimicrobial Powder Coating
|
Principle
Air Intake: Ambient air is drawn into the cabinet through an intake grille.
Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.
Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.
Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.
User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.
Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.
Consistent Environment: Provides a stable and sterile environment for sensitive applications.
Accessories
Stainless Steel Orifice Tabletop
ULPA Ultra GX Filter
UV Germicidal Lamps
De-static equipment
Support Stand with Caster Wheels
FAQ
1. How to monitor the performance of a vertical laminar flow cabinet over time?
To monitor the performance of a vertical laminar flow cabinet over time, regular checks are essential. Perform airflow velocity tests and particle count measurements periodically. Additionally, schedule routine maintenance and filter replacements to ensure consistent performance.
2. What are the environmental benefits of using vertical flow cleanbenches?
Vertical flow cleanbenches offer environmental benefits by reducing the need for chemical disinfectants and sterilizers, as they maintain a sterile environment through HEPA filtration. This minimizes chemical waste and lowers the overall environmental impact of laboratory operations.
3. What is the lifespan of a vertical laminar flow cabinet filter?
The lifespan of a vertical laminar flow cabinet filter typically ranges from 1 to 3 years, depending on usage frequency and the level of contaminants in the environment. Regular inspections and timely replacements are crucial to maintain optimal performance.
4. How to ensure compliance with regulations for vertical flow cleanbenches?
To ensure compliance with regulations for vertical flow cleanbenches, follow these steps:
Familiarize yourself with relevant industry standards and guidelines.
Perform regular audits and inspections.
Maintain thorough documentation of maintenance and testing activities.
5. What is the principle of laminar flow in cleanbenches?
The principle of laminar flow in cleanbenches involves creating a consistent, unidirectional stream of filtered air that moves at a uniform speed. This airflow pattern minimizes turbulence and prevents contaminants from settling, ensuring a clean working environment.
6. What is the difference between vertical and horizontal laminar flow cabinets?
Vertical laminar flow cabinets direct air vertically downwards onto the work surface, while horizontal laminar flow cabinets direct air horizontally from the back of the unit towards the user. This difference affects the types of applications each cabinet is best suited for, with vertical cabinets often used to protect sensitive samples and horizontal cabinets commonly used for personal protection.
7. What are the best practices for using a vertical laminar flow cabinet?
Best practices for using a vertical laminar flow cabinet include:
Ensure hands and materials are clean before use.
Minimize movements inside the cabinet to reduce turbulence.
Regularly clean and disinfect the work surface.
8. What are the guidelines for working with sensitive materials in a vertical flow cleanbench?
When working with sensitive materials in a vertical flow cleanbench, follow these guidelines:
Use personal protective equipment (PPE) to avoid contamination.
Handle materials gently to prevent particle generation.
Keep the work surface organized and free of unnecessary items to maintain airflow integrity.
9. How to achieve laminar flow in a contaminated environment?
To achieve laminar flow in a contaminated environment, ensure that the HEPA filters are functioning correctly and replace them as needed. Conduct regular airflow tests to verify uniformity and remove any potential sources of contamination from the vicinity of the cleanbench.
10. How to handle spillages in a vertical flow cleanbench?
In the event of a spillage in a vertical flow cleanbench, immediately stop all work and clean the spill using appropriate disinfectants and absorbent materials. Ensure that the area is thoroughly disinfected and the airflow is not obstructed. Resume work only when the area is confirmed to be clean and sterile.
11. How to ensure proper sealing in a vertical laminar flow cabinet?
Ensure proper sealing in a vertical laminar flow cabinet by regularly inspecting the gaskets and seals for any signs of wear or damage. Replace any compromised components promptly to maintain an airtight environment. Additionally, perform periodic smoke tests to check for any leaks.
12. What are the applications of vertical laminar flow cabinets in laboratories?
Vertical laminar flow cabinets are used in laboratories for various applications, including:
Sterile sample preparation.
Cell culture work.
Pharmaceutical compounding.
13. What standards regulate vertical flow cleanbenches?
Standards regulating vertical flow cleanbenches include:
ISO 14644 for cleanroom and associated controlled environments.
NSF/ANSI 49 for biosafety cabinetry.
EN 12469 for microbiological safety cabinets.
14. How to upgrade an existing vertical laminar flow cabinet?
To upgrade an existing vertical laminar flow cabinet, consider the following steps:
Assess current performance and identify areas for improvement.
Upgrade to higher efficiency HEPA or ULPA filters.
Integrate advanced monitoring systems for continuous performance checks.
15. What is the role of airflow uniformity in vertical flow cleanbenches?
Airflow uniformity in vertical flow cleanbenches ensures that a consistent, unidirectional stream of clean air is maintained across the entire work surface. This uniformity is crucial for preventing contamination and ensuring a sterile working environment, protecting both samples and processes.
16. How to test the efficiency of a vertical laminar flow cabinet?
To test the efficiency of a vertical laminar flow cabinet:
Measure airflow velocity using an anemometer.
Conduct particle count tests to check for contamination.
Perform smoke tests to visualize airflow patterns and identify any disruptions.
17. How to ensure consistent performance of a vertical laminar flow cabinet?
Ensure consistent performance of a vertical laminar flow cabinet by:
Conducting regular maintenance and filter replacements.
Performing routine performance tests, including airflow and particle count measurements.
Keeping the work area clean and free of obstructions.
Factory Production Workshop Video
Factory Photo
Product Packaging And International Logistics
Product International Certification
Find Other Common Equipment Recommendations
-
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 Set -
Air Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 Set -
Downflow Booth
US$3000-6000 USD/Unit
Min. Order:1 Set -
Clean bench
US$600-2000 USD/Unit
Min. Order:1 Set -
Air Filter
US$3-50 USD/Unit
Min. Order:1 Set -
Cleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:1 Set -
Pass Box
US$200-500 USD/Unit
Min. Order:1 Set -
FFU
US$135-350 USD/Unit
Min. Order:1 Set -
Fume Hood
US$700-1500 USD/Unit
Min. Order:1 Set -
Cleanroom HVAC
US$5000-20000 USD/Unit
Min. Order:1 Set -
Clean room floor
US$5-20 USD/Sq.
Min. Order:1 Set -
Clean room ceiling
US$
Min. Order:1 Set