MENU
X

9 ft Vertical Laminar Flow Cabinet

Reference Price:US$from $3000

Short Description:

A 9 ft Vertical Laminar Flow Cabinet offers a spacious, sterile work area by directing HEPA-filtered air in a vertical laminar flow pattern, ensuring a contamination-free environment.

  • Air Flow: Vertical flow
  • Available sizes: 9 ft
  • size: 2700×850×1500
  • Operating surface: One-sided
  • Internal height: 2 ft
  • Cleanbench Air Filter: ULPA Filter
  • Power Supply Configuration: 115V、20A North America、230V British (UK)、230V China/Australia、230V India、230V Schuko、230V 100V、 20A
  • Applicable area: USA Europe Malaysia Canada Middle East Indonesia
  • Customs code: 8421399090

Cleanroom

9 ft Vertical Laminar Flow Cabinet

Choose your installation & validation options below

  • Quantity:

Choose your upgrade options

  • Quantity:

Summary

Cleanroom

9 ft Vertical Laminar Flow Cabinet

Choose your installation & validation options below

Validation

Installation & Validation

Choose your upgrade options

Product Briefing

A 9 ft Vertical Laminar Flow Cabinet offers a spacious, sterile work area by directing HEPA-filtered air in a vertical laminar flow pattern, ensuring a contamination-free environment. Featuring durable stainless steel construction, clear side panels for visibility, and adjustable airflow controls, this cabinet is ideal for large-scale applications in pharmaceuticals, biotechnology, and electronics where maintaining clean conditions is critical.

laminar flow hoods Product Poster .jpg

Applications

  • Microbiology: Ideal for working with cultures, cell lines, and other sensitive biological materials.

  • Pharmaceuticals: Used in the preparation and compounding of sterile medications.

  • Electronics: Suitable for assembling and handling sensitive electronic components that may be susceptible to dust or static.

  • Research: Provides a clean environment for various scientific experiments and procedures.

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Models

Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization
Vertical Laminar Flow Clean Bench
ModelGDC-SPT-01GDC-SPT-02GDC-SPT-03

3 ft4ft5ft
External size W×D×H(mm)1000×850×15001200×850×15001500×850×1500
Internal Size W×D×H(mm)960×600×6001160×600×6001460×600×600
HEPA Filter(mm)905×585×69×1 Pcs1105×585×69×1 Pcs1405×585×69×1 Pcs
HEPA Filter Efficiency99.95%@0.3μm99.95%@0.3μm99.95%@0.3μm
G4 Pre Filter(mm)500×375×21×1 Pcs500×375×21×1 Pcs745×375×21×1 Pcs
Noise52~62dB(A)52~62dB(A)52~62dB(A)
Fan Pressure260pa260pa260pa
Fan Power (W)200W×1 Pcs200W×1 Pcs200W×1 Pcs
LED Lamp Power(W)12W×1 Pcs18W×1 Pcs30W×1 Pcs
Air Velocity(m/s)0.45m/s±20%
Clean LevelISO 5
Supply PowerAC 1N 220V/50Hz
Control System4.3"touch screen,3 stage regulation,light,sterilization

Supply PowerAC 1N 220V/50HzControl System4.3"touch screen,3 stage regulation,light,sterilization

Features

High-Quality Construction

  • Stainless steel worktop

  • Spill-retaining design will ensure containment of accidental liquid spills

Quiet Operation

  • Comfortable low noise at 52 dBA

  • Reduce fatigue and improve work concentration

ULPA Filter

  • 10x Filtration efficiency of HEPA filter Creates ISO Class 3 work zone instead of industry-standard ISO Class 5

Energy-efficient
  • Powered by latest generation DC ECM blower, that is more efficient than legacy ECM and VFD motors

  • 70% Energy savings compared to AC motor

  • Stable airflow, despite building voltage fluctuations & filter loading

GDC™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Principle

  • Air Intake: Ambient air is drawn into the cabinet through an intake grille.

  • Filtration: The air passes through a HEPA filter, removing 99.97% of particles ≥0.3 microns.

  • Laminar Airflow: Filtered air is directed vertically downward in a smooth, uninterrupted flow.

  • Clean Workspace: The downward airflow creates a contamination-free zone, protecting the work area and materials.

  • User Safety: The design minimizes exposure to airborne contaminants, enhancing operator safety.

  • Maintained Pressure: The cabinet maintains a slight negative pressure to prevent external contaminants from entering.

  • Consistent Environment: Provides a stable and sterile environment for sensitive applications.

Ultra-clean bench working principle.jpg


Accessories

  • Stainless Steel Orifice Tabletop

  • ULPA Ultra GX Filter

  • UV Germicidal Lamps

  • De-static equipment

  • Support Stand with Caster Wheels

FAQ

1. What are the safety features of a vertical laminar flow cabinet?

Vertical laminar flow cabinets typically include several safety features such as HEPA or ULPA filters to ensure a contaminant-free environment, UV sterilization lights to disinfect the work area, and an alarm system to alert users of filter malfunctions or airflow disruptions. These features help maintain a sterile workspace and protect both the user and the materials being handled.


2. What is the cost of a vertical flow cleanbench?

The cost of a vertical flow cleanbench varies widely depending on the size, features, and manufacturer. Prices typically range from $2,000 to $10,000 or more. Factors such as advanced filtration systems, additional functionalities, and custom configurations can affect the overall price.


3. What type of filter is used in a vertical laminar flow cabinet?

A vertical laminar flow cabinet uses HEPA (High-Efficiency Particulate Air) filters to remove 99.99% of particles down to 0.3 microns, ensuring a sterile work environment. Some models may also use ULPA (Ultra-Low Penetration Air) filters, which offer an even higher level of filtration efficiency.


4. What are the benefits of using a vertical flow cleanbench in microbiology?

Using a vertical flow cleanbench in microbiology provides a sterile environment, essential for preventing contamination of cultures and samples. The vertical airflow minimizes cross-contamination risks and protects both the user and the materials. This controlled environment ensures accurate and reliable experimental results.


5. What is the role of airflow uniformity in vertical flow cleanbenches?

Airflow uniformity in vertical flow cleanbenches is crucial for maintaining a consistent sterile environment. Uniform airflow ensures that contaminants are continuously swept away from the work area, minimizing the risk of particulate accumulation and cross-contamination. This consistency is vital for processes requiring high levels of cleanliness.


6. What is a vertical laminar flow cabinet?

A vertical laminar flow cabinet is a workbench designed to provide a sterile environment by directing HEPA-filtered air in a vertical laminar flow pattern. This protects the workspace from contamination, making it ideal for sensitive applications in fields such as microbiology, pharmaceuticals, and electronics.


7. How to upgrade an existing vertical laminar flow cabinet?

Upgrading an existing vertical laminar flow cabinet can include installing higher efficiency filters, such as ULPA filters, and adding features like UV sterilization lights or more advanced airflow control systems. Consulting with the manufacturer for compatible upgrades and proper installation is essential for maintaining performance and safety.


8. What is the role of pre-filters in a vertical laminar flow cabinet?

Pre-filters in a vertical laminar flow cabinet capture larger particles before air reaches the HEPA or ULPA filters. This reduces the load on the main filters, extending their lifespan and maintaining optimal airflow. Regular maintenance and replacement of pre-filters are essential for efficient cabinet operation.


9. What training is required for using a vertical flow cleanbench?

Training for using a vertical flow cleanbench includes understanding aseptic techniques, proper gowning and gloving procedures, and routine maintenance tasks. Users should also be instructed on how to handle equipment safely and respond to alarms or malfunctions to ensure a sterile and safe working environment.


10. What is the difference between a cleanbench and a fume hood?

A cleanbench provides a sterile environment by directing HEPA-filtered air over the work area, protecting the product from contamination. In contrast, a fume hood is designed to protect the user from hazardous fumes and vapors by exhausting air outside or through filters, without necessarily providing a sterile environment.


11. What are the benefits of using a vertical laminar flow cabinet?

Vertical laminar flow cabinets offer a sterile and particle-free work environment, crucial for sensitive processes. They protect both the product and the user, minimize contamination risks, and are versatile for use in various industries, including pharmaceuticals, biotechnology, and electronics.


12. How to measure the effectiveness of a vertical laminar flow cabinet?

To measure the effectiveness of a vertical laminar flow cabinet, conduct airflow velocity tests using an anemometer to ensure the airflow is within the specified range. Perform particle count tests to confirm air cleanliness standards. Regular documentation and analysis of these results help maintain optimal cabinet performance.


13. What are the airflow patterns in a vertical laminar flow cabinet?

In a vertical laminar flow cabinet, air is drawn through HEPA filters at the top of the cabinet and directed downward in a vertical laminar flow pattern. This ensures a continuous flow of clean air over the work area, pushing contaminants away and maintaining a sterile environment.


14. What industries use vertical laminar flow cleanbenches?

Vertical laminar flow cleanbenches are used in various industries, including pharmaceuticals, biotechnology, electronics, and medical device manufacturing. They provide a sterile environment essential for processes that require high levels of cleanliness and contamination control.


15. How to ensure proper airflow in a vertical flow cleanbench?

Ensure proper airflow in a vertical flow cleanbench by regularly inspecting and replacing filters, conducting routine airflow velocity tests, and keeping the work area free from obstructions. Proper maintenance and calibration are essential for maintaining optimal airflow and a sterile environment.


16. How to design a laboratory layout with vertical laminar flow cabinets?

Designing a laboratory layout with vertical laminar flow cabinets involves strategic placement to optimize workflow and ensure easy access. Consider factors like space requirements, air circulation, and proximity to other equipment. Adequate spacing between cabinets is crucial to prevent airflow disruption and maintain a sterile environment.


17. What are the installation requirements for a vertical flow cleanbench?

Installation requirements for a vertical flow cleanbench include a stable, level surface to ensure proper operation, access to a power supply for the filtration system, and sufficient clearance around the unit for unimpeded airflow. Proper positioning away from high-traffic areas and sources of contamination is also essential for maintaining sterility.


Factory Production Workshop Video

Factory Photo

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product Packaging And International Logistics

  • Production workshop photos1
  • Production workshop photos2
  • Production workshop photos3
  • Production workshop photos4
  • Production workshop photos5
  • Production workshop photos6
  • Production workshop photos7
  • Production workshop photos8
  • Production workshop photos9

Product International Certification

Enterprise qualification certificate

Leave Your Message


LEAVE A MESSAGE

If you are interested in our products and want to know moredetails,please leave a message here,we will reply you as soon as we can.