Air shower room (AIR SHOWER) is also called air shower, clean air shower room, clean air shower room, air shower room, air shower room, air shower door, dust shower room, air shower room, air shower channel, air shower room.
Air shower room is a necessary passage to enter the clean room, which can reduce the pollution problems caused by entering and exiting the clean room.
Types of Air Showers:
Min. Order:1 Set
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Min. Order:1 unit
Modular CleanRoom
US$9000-10000 USD/Unit
Min. Order:1 unitAir Shower
US$1000.00-5000.00 USD/Unit
Min. Order:1 unitDownflow Booth
US$3000-6000 USD/Unit
Min. Order:1 unitClean bench
US$600-2000 USD/Unit
Min. Order:1 unitAir Filter
US$3-50 USD/Unit
Min. Order:1 unitCleanroom Wall Panels
US$10-20 USD/sq.
Min. Order:100 squareDeiiang is a trusted leader in the manufacturing of air showers, dedicated to providing innovative solutions for controlled environments. With years of experience in the industry, we specialize in designing and producing high-quality air shower systems that enhance cleanliness and efficiency in various applications, including pharmaceuticals, electronics, and food processing. Our commitment to excellence and customer satisfaction sets us apart as a reliable partner for businesses seeking to maintain stringent hygiene standards.
At Deiiang, we understand the importance of maintaining a contaminant-free environment. Our air showers are engineered with advanced filtration technology and powerful blowers to effectively remove dust and particles from personnel and materials entering clean areas. Each system can be customized to meet specific requirements, including size, airflow rate, and control options. With user-friendly interfaces and durable construction, our air showers are designed for optimal performance and longevity, ensuring your facility operates smoothly and remains compliant with industry regulations.
Particle Removal: Air showers effectively remove dust, debris, and other particles from clothing and surfaces by directing jets of high-pressure, filtered air at the person or object.
Prevention of Contamination: They prevent contaminants from entering sensitive areas like cleanrooms, laboratories, or manufacturing environments, helping to maintain the required cleanliness standards.
Air Filtration: The air used in air showers is typically filtered through HEPA (High-Efficiency Particulate Air) or ULPA (Ultra-Low Penetration Air) filters to ensure that the air is free of contaminants before it is blown onto users or items.
Compliance with Cleanroom Standards: Air showers are commonly used in industries such as pharmaceuticals, electronics, and biotechnology to meet cleanliness standards like ISO Class 5 or higher.
An air shower is used to remove contaminants from personnel, equipment, or goods before they enter cleanrooms or controlled environments. Here’s a step-by-step guide on how to use an air shower effectively:
1. Preparation:Ensure Proper Attire,Remove Items;
2. Entering the Air Shower:Approach the Air Shower,Enter the Unit;
3. Decontamination Process:Activation,Air Jets,Duration;
4. Exiting the Air Shower:Wait for the Cycle to Complete,Exit:Close the Door;
5. After Use:Inspect Yourself,Maintain Hygiene;
Purpose: An air shower is designed to remove contaminants from personnel or items before entering a cleanroom, while an airlock is used to isolate different environmental zones, preventing contamination between areas.
Functionality: An air shower uses high-velocity air to decontaminate, whereas an airlock relies on a pressure differential or physical barriers to control the movement of air and particles.
Usage: Air showers are used for cleaning individuals or goods, while airlocks are typically employed to control access and maintain cleanroom integrity.
The fan circulates filtered air—often through HEPA or ULPA filters—into the air shower chamber, ensuring that contaminants are effectively blown off the body, clothing, or equipment. By providing constant airflow, the air shower fan helps maintain the cleanliness and integrity of sensitive areas by minimizing the introduction of particles.
Basic air shower: Price is about $5,000 to $10,000 USD, suitable for single use, suitable for small cleanrooms.
Two-person air shower: Price is about $8,000 to $20,000 USD, suitable for medium flow, with double doors and enhanced air flow.
Custom air shower: Price can reach $15,000 to $50,000 USD, depending on the size, filtration system and automation features.
Air Shower Imports Under HS Code 73249000.
Single Air Shower:Designed for one person at a time.Ideal for smaller cleanroom environments or labs with low traffic.Typically used for personnel entry to decontaminate clothing and equipment.
Double Air Shower:Designed for two people at a time.Suitable for environments with moderate traffic or for shared entry points.Helps improve efficiency in areas where multiple people may need to enter simultaneously.
Multiple Air Shower:Accommodates multiple individuals (usually 3-4 or more) at once.Commonly used in manufacturing facilities or high-traffic cleanrooms.Reduces wait times and enhances throughput for large groups of people.
Cargo Air Shower:Designed for decontaminating materials or goods before they enter a cleanroom.Larger and more robust than personnel air showers.
Air showers typically run for about 20 to 30 seconds. Currently, Deiiang air showers are designed to be adjustable from 0 to 99 seconds, which is usually sufficient to remove most dust, particles and contaminants from people or objects before they enter a clean room or controlled environment. The exact duration may vary depending on the design of the air shower, airflow velocity and the level of contamination control required.
The size of an air shower room can vary based on its design and the number of users it is intended to accommodate. Below are typical dimensions for various types of air shower room
Single Entry: 1.2m x 1m x 2.1m
Double Entry: 1.2m x 2m x 2.1m
Channel: 3m to 1.2m x 3m x 2.1m
Cargo: 3m x 2m x 3m
These dimensions provide a general idea, but custom sizes are often available to meet specific requirements.
When the air shower room is used for a period of time, if the wind speed is very low, you should immediately check whether the filter of the air shower room has too much dust, and replace it with a new filter. It is usually necessary to replace it once every 1-6 months, and the high-efficiency filter is usually replaced once every 6-12 months.
If the air shower room cannot automatically sense the shower, check the light sensing system in the lower right corner of the box in the air shower room to see if the light sensing device is correctly installed.
If the emergency stop button is red, it means that the air shower room will not blow. You only need to press the emergency stop button again to work normally.
When the air shower room does not work, first check whether the emergency switch of the outer box of the disadvantageous shower door is blocked. If it is blocked, press it lightly with your hand, turn it to the right and let it go.
If the air shower room fan is reversed or the wind speed of the air shower room is very low, it is necessary to check whether the 380V three-phase four-wire line is connected in reverse. If the line source of the air shower room is reversed, the air shower room fan will not work or the wind speed of the reverse air shower room will decrease, and the circuit board of the entire air shower room will be burned in severe cases.
Air shower room is used in various dust-free workshops and non-dust-free workshops and step cleanliness workshops such as microelectronics, optoelectronics, semiconductors, medicine, food, chemicals, aviation, automobiles, printing, and laboratories. It is used to remove dust particles larger than 0.3 microns from various parts of the human body when entering a high-cleanliness room from a low-cleanliness room, so as to avoid contamination after entering the clean room. At the same time, it also plays the role of air flow buffering, because in the process of opening the door, there is air flow, and the air shower room stops the air flow inside the air shower room very well, which well avoids air pollution caused by air flow.
Fully automatic control, electronic interlocking, double door lock during showering, infrared induction automatic showering. Stainless steel semi-glass door automatic door closer, transparent window, inner lower plate is made of stainless steel; software test controller, LED display and setting shower time, adjustable range 0~99 seconds, circular involute air duct inside, high wind speed, low noise.
Humanized control panel design, clear indicator light indication, give clear air shower process indication. Soft key touch time relay;
High cleanliness, high wind speed: adopt primary and high efficiency filter two-stage filtration system, low resistance high efficiency filter without partition, filtration efficiency: 99.99%, ensure purification level. Equipped with all stainless steel multi-angle adjustable nozzle, double volute outer rotor large air volume low noise fan, the wind speed at the nozzle outlet is as high as 25m/s or more, and the wind speed blowing on the person is more than 18m/s.
Modular structure, the air shower room box adopts modular design scheme, which can be assembled into various lengths of air shower sizes according to actual needs. An air shower room consists of one or more air shower units. For large-volume air shower equipment, it can be disassembled into multiple modules, making production, transportation and installation particularly convenient and fast;
High performance, high sealing: imported electronic components are used, the operation performance is stable and reliable, advanced noise reduction and silencing device system and EVA sealing materials are used, and the sealing performance is high.
Automatic control, the single-person single-blow air shower room system adopts PLC intelligent control means, and the LED display screen on the control panel can correctly display the running status of the air shower, the interlocking status of the double doors, the progress of the air shower cycle and the delayed door opening status. It is also equipped with a photoelectric sensor, a one-way channel air shower room, and when entering from a non-clean area, the infrared ray senses the person and the shower starts after the door is closed. After the shower, the door is locked and the person can only leave the air shower room from the door;
The single-person single-blow air shower room mainboard soft key touch time relay, LED display and setting of the shower time, the range is adjustable from 10-99s, and the shower time can be adjusted according to the difference in the external environment of the air shower room;
Modular structure, the single-person single-blow air shower room box adopts a modular design scheme;
High performance, high sealing, using imported electronic components, stable and reliable operating performance, advanced noise reduction and silencing device system and EVA sealing materials, high sealing performance.
The air shower room is a necessary passage for people to enter the clean room. It can reduce the pollution problems caused by entering and exiting the clean room, and reduce the large amount of dust particles caused by the entry and exit of people and goods. Installing a fully functional "airlock" at the entrance of the clean room can reduce the number of air pollution particles.
When entering the clean room, you should take off your outer clothes in the outer dressing room, and remove your watches, mobile phones, accessories and other items.
When entering the inner dressing room, wear clean clothes, hats, masks and gloves.
After opening the stainless steel air shower door and entering the air shower room, the air shower door will automatically close the outer door immediately, infrared sensing, and the air shower will automatically start, blowing for 15 seconds.
When people and goods pass through the air shower room, the polluted particles are ejected by highly clean air that has been filtered through high efficiency. The high wind speed of more than 25m/s ensures that the effective injection and drifting particles are basically filtered out through the primary and high efficiency two-stage filters. In order to maintain the safe use of air showers and maintain the cleanliness of the clean room environment
Pre-filter: The pre-filter is located below the device. Please remove the circulating air return port to easily pull out the pre-filter. The blockage of the pre-filter varies depending on the frequency of use and cleanliness. Please observe the blockage time in the initial use, and then clean it regularly by compressed air, water washing, vacuum cleaning, etc. It is necessary to clean it 2 to 3 times a month according to normal use.
Main filter: This filter is located after the AIR NOZZLE. Its renewal period can be determined by the wind speed value detected by the anemometer (the wind value is halved) or the pressure difference measured by the pressure difference meter (the pressure difference value is doubled). The inspection cycle is about two to four times a year.
Because the internal circulation return air part of the equipment is located below the machine, there will be large pollutants accumulated in the corners on the bottom plate, so please clean it with a vacuum cleaner at least once a week. Please confirm whether the rotation direction of the blower is correct. If the fan is found to be rotating in the opposite direction (wind speed is obviously insufficient), please swap any two phases of the three-phase power supply to ensure that it rotates in the positive direction.